Floors made of precast concrete hollow-core slabs may be constructed without a structural concrete topping and with transverse tie reinforcement placed only out of the slabs. Longitudinal joints between adjacent precast units are filled with mortar on site. To ensure good diaphragm performance under seismic action, a special joint has been devised, in which the slab sides are profiled as continuous sinusoidal waved shear keys. The research involved experimental investigations and analytical modeling. The features of the joint and the means of production were first worked out. Then, a series of destructive tests were performed, on both short joint samples and full-scale floors, made of extruded prestressed hollow-core slabs without topping, all subjected to large in-plane loading reversals. They showed that, after the adhesion between the grout and precast concrete is overcome, a stable cyclic shear transfer mechanism develops, based on wedge action and friction raised at the wavy slab–mortar interface. Th...
[1]
Theodossius P. Tassios,et al.
Concrete‐to‐Concrete Friction
,
1987
.
[2]
Saad E. Moustafa.
Effectiveness of Shear-Friction Reinforcement in Shear Diaphragm Capacity of Hollow-Core Slabs
,
1981
.
[3]
John F. Stanton,et al.
NEW SEISMIC DESIGN PROVISIONS FOR DIAPHRAGMS IN PRECAST CONCRETE PARKING STRUCTURES
,
2000
.
[4]
José I. Restrepo,et al.
Earthquake‐induced floor horizontal accelerations in buildings
,
2002
.
[5]
Robert B. Fleischman,et al.
Dynamic behavior of perimeter lateral‐system structures with flexible diaphragms
,
2001
.
[6]
Richard Sause,et al.
Seismic behavior of precast parking structure diaphragms
,
1996
.