Pediatric Transthoracic Cardiac Vector Flow Imaging – A Preliminary Pictorial Study

Purpose Conventional pediatric echocardiography is crucial for diagnosing congenital heart disease (CHD), but the technique is impaired by angle dependency. Vector flow imaging (VFI) is an angle-independent noninvasive ultrasound alternative for blood flow assessment and can assess complex flow patterns not visible on conventional Doppler ultrasound. Materials and Methods 12 healthy newborns and 3 infants with CHD were examined with transthoracic cardiac VFI using a conventional ultrasound scanner and a linear array. Results VFI examinations revealed common cardiac flow patterns among the healthy newborns, and flow changes among the infants with CHD not previously reported with conventional echocardiography. Conclusion For assessment of cardiac flow in the normal and diseased pediatric heart, VFI may provide additional information compared to conventional echocardiography and become a useful diagnostic tool.

[1]  Kristoffer Lindskov Hansen,et al.  Intra-Operative Vector Flow Imaging Using Ultrasound of the Ascending Aorta among 40 Patients with Normal, Stenotic and Replaced Aortic Valves. , 2016, Ultrasound in medicine & biology.

[2]  Kristoffer Lindskov Hansen,et al.  Analysis of Systolic Backflow and Secondary Helical Blood Flow in the Ascending Aorta Using Vector Flow Imaging. , 2016, Ultrasound in medicine & biology.

[3]  S. Grieve,et al.  4D flow magnetic resonance imaging: role in pediatric congenital heart disease , 2018, Asian cardiovascular & thoracic annals.

[4]  J A Jensen,et al.  A new estimator for vector velocity estimation. , 2001, IEEE transactions on ultrasonics, ferroelectrics, and frequency control.

[5]  M. Markl,et al.  Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance , 2011, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[6]  K. Deeg Echocardiographic Differential Diagnosis of the Cyanotic Newborn , 2014, Ultraschall in der Medizin.

[7]  Jørgen Arendt Jensen,et al.  Convex array vector velocity imaging using transverse oscillation and its optimization , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[8]  J. Jensen,et al.  Phased-array vector velocity estimation using transverse oscillations , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[9]  W. R. Dean,et al.  Note on the motion of fluid in a curved pipe , 1959 .

[10]  M. Markl,et al.  4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography , 2015, Pediatric Radiology.

[11]  Kristoffer Lindskov Hansen,et al.  Aortic Valve Stenosis Increases Helical Flow and Flow Complexity: A Study of Intra-Operative Cardiac Vector Flow Imaging. , 2017, Ultrasound in medicine & biology.

[12]  T. Leiner,et al.  Diagnosis, imaging and clinical management of aortic coarctation , 2017, Heart.

[13]  Tal Geva,et al.  Multimodality Noninvasive Imaging for Assessment of Congenital Heart Disease , 2010, Circulation. Cardiovascular imaging.

[14]  G. Trahey,et al.  Angle Independent Ultrasonic Detection of Blood Flow , 1987, IEEE Transactions on Biomedical Engineering.

[15]  M. Fox Multiple crossed-beam ultrasound Doppler velocimetry , 1978 .

[16]  Kristoffer Lindskov Hansen,et al.  Ultrasonic 3-D Vector Flow Method for Quantitative In Vivo Peak Velocity and Flow Rate Estimation , 2017, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[17]  Kristoffer Lindskov Hansen,et al.  Intraoperative Cardiac Ultrasound Examination Using Vector Flow Imaging , 2013, Ultrasonic imaging.

[18]  M. Yacoub,et al.  Asymmetric redirection of flow through the heart , 2000, Nature.

[19]  W. R. Dean XVI. Note on the motion of fluid in a curved pipe , 1927 .

[20]  Kristoffer Lindskov Hansen,et al.  First report on intraoperative vector flow imaging of the heart among patients with healthy and diseased aortic valves. , 2015, Ultrasonics.

[21]  J. Jensen,et al.  Vector Flow Imaging Compared with Conventional Doppler Ultrasound and Thermodilution for Estimation of Blood Flow in the Ascending Aorta , 2017, Ultrasonic imaging.

[22]  T. Sawa,et al.  Vector flow mapping analysis of left ventricular energetic performance in healthy adult volunteers , 2017, BMC Cardiovascular Disorders.

[23]  A. Bharadwaj,et al.  Echocardiographic Evaluation of Tetralogy of Fallot , 2015, Echocardiography.

[24]  J. Jensen,et al.  A new estimator for vector velocity estimation [medical ultrasonics] , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  J. Jensen,et al.  A new method for estimation of velocity vectors , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  Lasse Lovstakken,et al.  Shunt flow evaluation in congenital heart disease based on two-dimensional speckle tracking. , 2014, Ultrasound in medicine & biology.

[27]  E. Ritenour Doppler Ultrasound: Physics, Instrumentation and Clinical Applications , 1990 .

[28]  G. Greve,et al.  Trends in pediatric imaging: ultrasound , 2013, Acta radiologica.

[29]  J. Roos‐Hesselink,et al.  Birth prevalence of congenital heart disease worldwide: a systematic review and meta-analysis. , 2011, Journal of the American College of Cardiology.

[30]  J. Erdmenger Orellana [Recent advances in pediatric echocardiography]. , 2003, Archivos de cardiologia de Mexico.

[31]  Boudewijn P F Lelieveldt,et al.  Vortex flow during early and late left ventricular filling in normal subjects: quantitative characterization using retrospectively-gated 4D flow cardiovascular magnetic resonance and three-dimensional vortex core analysis , 2014, Journal of Cardiovascular Magnetic Resonance.