Fabrication of 200 nm period centimeter area hard x-ray absorption gratings by multilayer deposition

We describe the design and fabrication trials of x-ray absorption gratings of 200?nm period and up to 100:1 depth-to-period ratios for full-field hard x-ray imaging applications. Hard x-ray phase-contrast imaging relies on gratings of ultra-small periods and sufficient depth to achieve high sensitivity. Current grating designs utilize lithographic processes to produce periodic vertical structures, where grating periods below 2.0??m are difficult due to the extreme aspect ratios of the structures. In our design, multiple bilayers of x-ray transparent and opaque materials are deposited on a staircase substrate, and mostly on the floor surfaces of the steps only. When illuminated by an x-ray beam horizontally, the multilayer stack on each step functions as a micro-grating whose grating period is the thickness of a bilayer. The array of micro-gratings over the length of the staircase works as a single grating over a large area when continuity conditions are met. Since the layers can be nanometers thick and many microns wide, this design allows sub-micron grating periods and sufficient grating depth to modulate hard x-rays. We present the details of the fabrication process and diffraction profiles and contact radiography images showing successful intensity modulation of a 25?keV x-ray beam.

[1]  Han Wen,et al.  Theory of oblique and grazing incidence Talbot‑Lau interferometers and demonstration in a compact source x‑ray reflective interferometer , 2011, Optics express.

[2]  Atsushi Momose,et al.  Demonstration of X-Ray Talbot Interferometry , 2003 .

[3]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[4]  Han Wen,et al.  Spatial Harmonic Imaging of X-ray Scattering—Initial Results , 2008, IEEE Transactions on Medical Imaging.

[5]  H. C. Kang,et al.  Nanometer linear focusing of hard x rays by a multilayer Laue lens. , 2006, Physical review letters.

[6]  M. S. Millán Advanced optical correlation and digital methods for pattern matching—50th anniversary of Vander Lugt matched filter , 2012 .

[7]  Do Young Noh,et al.  Observation of the Talbot effect using broadband hard x-ray beam. , 2010, Optics express.

[8]  Franz Pfeiffer,et al.  Inverse geometry for grating-based x-ray phase-contrast imaging , 2009 .

[9]  A. Takeuchi,et al.  Hard-X-ray phase-difference microscopy using a fresnel zone plate and a transmission grating. , 2009, Physical review letters.

[10]  O. Bunk,et al.  The fractional Talbot effect in differential x‐ray phase‐contrast imaging for extended and polychromatic x‐ray sources , 2008, Journal of microscopy.

[11]  D. Sayre,et al.  X-ray microscopy of biological objects with carbon kappa and with synchrotron radiation. , 1976, Science.

[12]  T Suzuki,et al.  Shearing interferometer using the grating as the beam splitter. , 1971, Applied optics.

[13]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[14]  Grazing angle Mach-Zehnder interferometer using reflective phase gratings and a polychromatic, un-collimated light source. , 2010, Optics express.

[15]  Atsushi Momose,et al.  Grating-Based X-ray Phase Imaging Using Multiline X-ray Source , 2009 .

[16]  Juergen Mohr,et al.  Soft X-ray lithography of high aspect ratio SU8 submicron structures , 2008 .

[17]  C. David,et al.  Differential x-ray phase contrast imaging using a shearing interferometer , 2002 .

[18]  Franz Pfeiffer,et al.  X-ray phase radiography and tomography of soft tissue using grating interferometry. , 2008, European journal of radiology.

[19]  D. L. Voronov,et al.  High-efficiency 5000 lines/mm multilayer-coated blazed grating for extreme ultraviolet wavelengths. , 2010, Optics letters.

[20]  A. Macrander,et al.  Depth-graded multilayers for application in transmission geometry as linear zone plates , 2005 .

[21]  P Cloetens,et al.  Fractional Talbot imaging of phase gratings with hard x rays. , 1997, Optics letters.

[22]  Atsushi Momose,et al.  X-Ray Phase Imaging with Single Phase Grating , 2007 .

[23]  F. Pfeiffer,et al.  Advanced phase-contrast imaging using a grating interferometer. , 2009, Journal of synchrotron radiation.

[24]  Franz Pfeiffer,et al.  Fabrication of diffraction gratings for hard X-ray phase contrast imaging , 2007 .

[25]  Jörg Maser,et al.  Focusing of hard x-rays to 16 nanometers with a multilayer Laue lens , 2008 .

[26]  Dumitru Mazilu,et al.  Multilayer-coated micro-grating array for x-ray phase-contrast imaging , 2011, Optics + Optoelectronics.

[27]  Franz Pfeiffer,et al.  Soft-tissue phase-contrast tomography with an x-ray tube source , 2009, Physics in medicine and biology.

[28]  Mark L. Schattenburg,et al.  High fidelity blazed grating replication using nanoimprint lithography , 2004 .

[29]  Han Wen,et al.  Fourier X-ray scattering radiography yields bone structural information. , 2009, Radiology.

[30]  Kejun Kang,et al.  Quantitative grating-based x-ray dark-field computed tomography , 2009 .

[31]  Franz Pfeiffer,et al.  Phase-contrast imaging and tomography at 60 keV using a conventional x-ray tube source. , 2009, The Review of scientific instruments.

[32]  Claus-Peter Richter,et al.  Imaging of cochlear tissue with a grating interferometer and hard X‐rays , 2009, Microscopy research and technique.

[33]  Ying Liu,et al.  Vacuum-ultraviolet blazed silicon grating anisotropically etched by native-oxide mask. , 2009, Optics letters.

[34]  Atsushi Momose,et al.  Fabrication of large area diffraction grating using LIGA process , 2008 .

[35]  Atsushi Momose,et al.  Phase Tomography by X-ray Talbot Interferometry for Biological Imaging , 2006 .