A fully automated cell segmentation and morphometric parameter system for quantifying corneal endothelial cell morphology

BACKGROUND AND OBJECTIVE Corneal endothelial cell abnormalities may be associated with a number of corneal and systemic diseases. Damage to the endothelial cells can significantly affect corneal transparency by altering hydration of the corneal stroma, which can lead to irreversible endothelial cell pathology requiring corneal transplantation. To date, quantitative analysis of endothelial cell abnormalities has been manually performed by ophthalmologists using time consuming and highly subjective semi-automatic tools, which require an operator interaction. We developed and applied a fully-automated and real-time system, termed the Corneal Endothelium Analysis System (CEAS) for the segmentation and computation of endothelial cells in images of the human cornea obtained by in vivo corneal confocal microscopy. METHODS First, a Fast Fourier Transform (FFT) Band-pass filter is applied to reduce noise and enhance the image quality to make the cells more visible. Secondly, endothelial cell boundaries are detected using watershed transformations and Voronoi tessellations to accurately quantify the morphological parameters of the human corneal endothelial cells. The performance of the automated segmentation system was tested against manually traced ground-truth images based on a database consisting of 40 corneal confocal endothelial cell images in terms of segmentation accuracy and obtained clinical features. In addition, the robustness and efficiency of the proposed CEAS system were compared with manually obtained cell densities using a separate database of 40 images from controls (n = 11), obese subjects (n = 16) and patients with diabetes (n = 13). RESULTS The Pearson correlation coefficient between automated and manual endothelial cell densities is 0.9 (p < 0.0001) and a Bland-Altman plot shows that 95% of the data are between the 2SD agreement lines. CONCLUSIONS We demonstrate the effectiveness and robustness of the CEAS system, and the possibility of utilizing it in a real world clinical setting to enable rapid diagnosis and for patient follow-up, with an execution time of only 6 seconds per image.

[1]  Wilhelm Burger,et al.  Digital Image Processing - An Algorithmic Introduction using Java , 2008, Texts in Computer Science.

[2]  A. Ruggeri,et al.  Corneal Endothelium Cell Field Analysis by means of Interacting Bayesian Shape Models , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[3]  Alfredo Ruggeri,et al.  Segmentation of Corneal Endothelial Cells Contour by Means of a Genetic Algorithm , 2015 .

[4]  Kethepalli Mallikarjuna,et al.  Image Compression and Reconstruction using Discrete Rajan Transform Based Spectral Sparsing , 2016 .

[5]  Adam Piórkowski,et al.  Cell Detection in Corneal Endothelial Images Using Directional Filters , 2015, IP&C.

[6]  Jitendra Malik,et al.  A database of human segmented natural images and its application to evaluating segmentation algorithms and measuring ecological statistics , 2001, Proceedings Eighth IEEE International Conference on Computer Vision. ICCV 2001.

[7]  Motohide Yoshimura,et al.  Convolution neural network for contour extraction of corneal endothelial cells , 2017, International Conference on Quality Control by Artificial Vision.

[8]  Serge Beucher,et al.  The Morphological Approach to Segmentation: The Watershed Transformation , 2018, Mathematical Morphology in Image Processing.

[9]  Sadi Gundogdu,et al.  Corneal endothelial cell density and morphology in patients with acromegaly. , 2014, Growth hormone & IGF research : official journal of the Growth Hormone Research Society and the International IGF Research Society.

[10]  Sunil Agrawal,et al.  Integration of Clustering, Optimization and Partial Differential Equation Method for Improved Image Segmentation , 2012 .

[11]  Jean-Charles Pinoli,et al.  Comparison and Supervised Learning of Segmentation Methods Dedicated to Specular Microscope Images of Corneal Endothelium , 2014, Int. J. Biomed. Imaging.

[12]  M. Doughty,et al.  Further analysis of assessments of the coefficient of variation of corneal endothelial cell areas from specular microscopic images , 2008, Clinical & experimental optometry.

[13]  P. Gain,et al.  Automated tri-image analysis of stored corneal endothelium , 2002, The British journal of ophthalmology.

[14]  Eero P. Simoncelli,et al.  Image quality assessment: from error visibility to structural similarity , 2004, IEEE Transactions on Image Processing.

[15]  Cris L. Luengo Hendriks,et al.  Fully automatic evaluation of the corneal endothelium from in vivo confocal microscopy , 2015, BMC Medical Imaging.

[16]  S. Beucher Use of watersheds in contour detection , 1979 .

[17]  Mitra Tavakoli,et al.  Corneal confocal microscopy: a novel non-invasive technique to quantify small fibre pathology in peripheral neuropathies. , 2011, Journal of visualized experiments : JoVE.

[18]  Karolina Nurzynska,et al.  Influence of applied corneal endothelium image segmentation techniques on the clinical parameters , 2017, Comput. Medical Imaging Graph..

[19]  Rami Qahwaji,et al.  An Automatic Corneal Subbasal Nerve Registration System Using FFT and Phase Correlation Techniques for an Accurate DPN Diagnosis , 2015, 2015 IEEE International Conference on Computer and Information Technology; Ubiquitous Computing and Communications; Dependable, Autonomic and Secure Computing; Pervasive Intelligence and Computing.

[20]  Lei Zhang,et al.  Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index , 2013, IEEE Transactions on Image Processing.

[21]  Anna Fabijanska,et al.  Corneal endothelium image segmentation using feedforward neural network , 2017, 2017 Federated Conference on Computer Science and Information Systems (FedCSIS).

[22]  Michael J Lynn,et al.  Review of corneal endothelial specular microscopy for FDA clinical trials of refractive procedures, surgical devices, and new intraocular drugs and solutions. , 2008, Cornea.

[23]  Jianjiang Xu,et al.  Comparison of human corneal cell density by age and corneal location: an in vivo confocal microscopy study , 2016, BMC Ophthalmology.

[24]  Mhd Saeed Sharif,et al.  An efficient system for preprocessing confocal corneal images for subsequent analysis , 2014, 2014 14th UK Workshop on Computational Intelligence (UKCI).

[25]  A. Ruggeri,et al.  A new system for the automatic estimation of endothelial cell density in donor corneas , 2005, British Journal of Ophthalmology.

[26]  J. Tukey,et al.  An algorithm for the machine calculation of complex Fourier series , 1965 .

[27]  Daniel Reem,et al.  The Geometric Stability of Voronoi Diagrams with Respect to Small Changes of the Sites , 2011, SoCG '11.

[28]  Tomoyuki Hiroyasu,et al.  Extracting Rules for Cell Segmentation in Corneal Endothelial Cell Images Using GP , 2013, 2013 IEEE International Conference on Systems, Man, and Cybernetics.

[29]  Tor P. Utheim,et al.  Substrates for Expansion of Corneal Endothelial Cells towards Bioengineering of Human Corneal Endothelium , 2015, Journal of functional biomaterials.

[30]  R. Qahwaji,et al.  An efficient intelligent analysis system for confocal corneal endothelium images , 2015, Comput. Methods Programs Biomed..

[31]  A. Ruggeri,et al.  A lattice estimation approach for the automatic evaluation of corneal endothelium density , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[32]  Alfredo Ruggeri,et al.  Segmentation of Corneal Endothelial Cells Contour through Classification of Individual Component Signatures , 2014 .

[33]  M. Meilă Comparing clusterings---an information based distance , 2007 .

[34]  Kim Young-Yoon,et al.  Image Analysis Algorithm for the Corneal Endothelium , 2006 .

[35]  Stanley S. Ipson,et al.  A fully automatic nerve segmentation and morphometric parameter quantification system for early diagnosis of diabetic neuropathy in corneal images , 2016, Comput. Methods Programs Biomed..

[36]  Mohammad Shorif Uddin,et al.  Accelerating Fast Fourier Transformation for Image Processing using Graphics Processing Unit , 2011 .

[37]  M. Foracchia,et al.  Cell contour detection in corneal endothelium in-vivo microscopy , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[38]  Nigel H Brookes,et al.  Morphometry of organ cultured corneal endothelium using Voronoi segmentation , 2017, Cell and Tissue Banking.