Omnidirectional Ultrasonic Powering for Millimeter-Scale Implantable Devices

In addition to superior energy-conversion efficiency at millimeter-scale dimensions, ultrasonic wireless powering offers deeper penetration depth and omnidirectionality as compared to the traditional inductive powering method. This makes ultrasound an attractive candidate for powering deep-seated implantable medical devices. In this paper, we investigate ultrasonic powering of millimeter-scale devices with specific emphasize on the output power levels, efficiency, range, and omnidirectionality. Piezoelectric receivers 1 × 5 × 1 mm3, 2 × 2 × 2 mm3, and 2 × 4 × 2 mm3 in size are able to generate 2.48, 8.7, and 12.0 mW of electrical power, while irradiated at 1.15 and 2.3 MHz within FDA limits for medical imaging (peak acoustic intensity of 720 mW/cm2). The receivers have corresponding efficiencies of 0.4%, 1.7%, and 2.7%, respectively, at 20-cm powering distance. Due to the form factor and reflections from tissue-air boundaries, the output power stays constant to within 92% when the angular positions of the transmitter and receiver are varied around a cylindrical shell.

[1]  W L Nyborg,et al.  Safety of medical diagnostic ultrasound. , 2002, Seminars in ultrasound, CT, and MR.

[2]  Max Wintermark,et al.  Potential intracranial applications of magnetic resonance-guided focused ultrasound surgery. , 2013, Journal of neurosurgery.

[3]  Maysam Ghovanloo,et al.  A Wide-Band Power-Efficient Inductive Wireless Link for Implantable Microelectronic Devices Using Multiple Carriers , 2007, IEEE Transactions on Circuits and Systems I: Regular Papers.

[4]  Yuji Tanabe,et al.  Wireless power transfer to deep-tissue microimplants , 2014, Proceedings of the National Academy of Sciences.

[5]  N Marangos,et al.  COCHLEAR IMPLANTS , 1976, The Lancet.

[6]  N. Cohen,et al.  Cochlear Implants , 2000 .

[7]  S. Ozeri,et al.  Ultrasonic transcutaneous energy transfer for powering implanted devices. , 2010, Ultrasonics.

[8]  Robert Puers,et al.  An inductive power link for a wireless endoscope. , 2007, Biosensors & bioelectronics.

[9]  Po-Jen Shih,et al.  Design, fabrication, and application of bio-implantable acoustic power transmission , 2010, Journal of Microelectromechanical Systems.

[10]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  Fan-Gang Zeng,et al.  Cochlear Implants: System Design, Integration, and Evaluation , 2008, IEEE Reviews in Biomedical Engineering.

[12]  M. Hennerici,et al.  Transcranial ultrasound-improved thrombolysis: diagnostic vs. therapeutic ultrasound. , 2001, Ultrasound in medicine & biology.

[13]  W.J. Heetderks,et al.  RF powering of millimeter- and submillimeter-sized neural prosthetic implants , 1988, IEEE Transactions on Biomedical Engineering.

[14]  Roy W. Martin,et al.  Force and electrical Thevenin equivalent circuits and simulations for thickness mode piezoelectric transducers , 1975 .

[15]  Shahriar Mirabbasi,et al.  Design and Optimization of Resonance-Based Efficient Wireless Power Delivery Systems for Biomedical Implants , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[16]  Catherine Dehollain,et al.  3.2 mW ultrasonic LSK modulator for uplink communication in deep implanted medical devices , 2014, 2014 IEEE Biomedical Circuits and Systems Conference (BioCAS) Proceedings.

[17]  S. Arra,et al.  Ultrasonic Power and Data Link for Wireless Implantable Applications , 2007, 2007 2nd International Symposium on Wireless Pervasive Computing.

[18]  Martin O Culjat,et al.  A review of tissue substitutes for ultrasound imaging. , 2010, Ultrasound in medicine & biology.

[19]  Tamotsu Katane,et al.  Power and Interactive Information Transmission to Implanted Medical Device Using Ultrasonic , 2002 .

[20]  Doron Shmilovitz,et al.  Simultaneous backward data transmission and power harvesting in an ultrasonic transcutaneous energy transfer link employing acoustically dependent electric impedance modulation. , 2014, Ultrasonics.

[21]  N.T. Songhvi,et al.  New developments in therapeutic ultrasound , 1996 .

[22]  Chua-Chin Wang,et al.  Noninvasive Control of the Power Transferred to an Implanted Device by an Ultrasonic Transcutaneous Energy Transfer Link , 2014, IEEE Transactions on Biomedical Engineering.

[23]  M C Ziskin,et al.  The sensitivity of biological tissue to ultrasound. , 1997, Ultrasound in Medicine and Biology.

[24]  Doron Shmilovitz,et al.  Ultrasonic transcutaneous energy transfer using a continuous wave 650 kHz Gaussian shaded transmitter. , 2010, Ultrasonics.

[25]  Eric M. Yeatman,et al.  Ultrasonic vs. Inductive Power Delivery for Miniature Biomedical Implants , 2010, 2010 International Conference on Body Sensor Networks.

[26]  J. Bosch,et al.  The bion device: a minimally invasive implantable ministimulator for pudendal nerve neuromodulation in patients with detrusor overactivity incontinence. , 2005, The Urologic clinics of North America.

[27]  Eduard R. Soudijn,et al.  SCANNING ELECTRON-MICROSCOPIC STUDY OF ORGAN OF CORTI IN NORMAL AND SOUND-DAMAGED GUINEA-PIGS , 1976 .

[28]  W. Ko,et al.  Design of radio-frequency powered coils for implant instruments , 1977, Medical and Biological Engineering and Computing.

[29]  B. Towe,et al.  Miniature ultrasonically powered wireless nerve cuff stimulator , 2011, 2011 5th International IEEE/EMBS Conference on Neural Engineering.

[30]  Jung Hyui Alumina/Epoxy Nanocomposite Matching Layers for High-Frequency Ultrasound Transducer Application , 2009 .

[31]  A. J. Mullholland,et al.  Properties of photocured epoxy resin materials for application in piezoelectric ultrasonic transducer matching layers. , 2010, The Journal of the Acoustical Society of America.

[32]  Babak Ziaie,et al.  An Ultrasonically Powered Implantable Micro-Oxygen Generator (IMOG) , 2011, IEEE Transactions on Biomedical Engineering.

[33]  Yoseph Rozenman,et al.  Wireless acoustic communication with a miniature pressure sensor in the pulmonary artery for disease surveillance and therapy of patients with congestive heart failure. , 2007, Journal of the American College of Cardiology.

[34]  K. Najafi,et al.  A single-channel implantable microstimulator for functional neuromuscular stimulation , 1997, IEEE Transactions on Biomedical Engineering.

[35]  G. L. Matthaei,et al.  Erratum: New equivalent circuits for elementary piezoelectric transducers , 1970 .

[36]  Diane Dalecki,et al.  Mechanical bioeffects of ultrasound. , 2004, Annual review of biomedical engineering.

[37]  G. Kino Acoustic waves : devices, imaging, and analog signal processing , 1987 .

[38]  Stephen D. O'Driscol A mm-sized implantable power receiver with adaptive matching , 2010, 2010 IEEE Sensors.

[39]  L. Crum,et al.  Physical mechanisms of the therapeutic effect of ultrasound (a review) , 2003 .