Probe calibration for freehand 3-D ultrasound.

Ultrasound (US) probe calibration establishes the rigid body transformation between the US image and a tracking device attached to the probe. This is an important requirement for correct 3-D reconstruction of freehand US images and, thus, for accurate surgical navigation based on US. In this study, we evaluated three methods for probe calibration, based on a single-point phantom, a wire-cross phantom requiring 2-D alignment and a wire phantom for freehand scanning. The processing of acquired data is fairly common to these methods and, to a great extent, based on automated procedures. The evaluation is based on quality measures in 2-D and 3-D reconstructed data. With each of the three methods, we calibrated a linear-array probe, a phased-array sector probe and an intraoperative probe. The freehand method performed best, with a 3-D navigation accuracy of 0.6 mm for one of the probes. This indicates that clinical accuracy in the order of 1 mm may be achieved in US-based surgical navigation.

[1]  Roy W. Martin,et al.  Three-dimensional ultrasound imaging using multiple magnetic tracking systems and miniature magnetic sensors , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[2]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[3]  F. Lindseth,et al.  SonoWand, an Ultrasound-based Neuronavigation System , 2000, Neurosurgery.

[4]  Frank Lindseth,et al.  A robust and automatic method for evaluating accuracy in 3-D ultrasound-based navigation. , 2003, Ultrasound in medicine & biology.

[5]  M.E. Legget,et al.  System for quantitative three-dimensional echocardiography of the left ventricle based on a magnetic-field position and orientation sensing system , 1998, IEEE Transactions on Biomedical Engineering.

[6]  K. S. Arun,et al.  Least-Squares Fitting of Two 3-D Point Sets , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[7]  Calvin R. Maurer,et al.  A fast and accurate method of ultrasound probe calibration for image-guided surgery , 2002 .

[8]  F. Lindseth,et al.  Accuracy evaluation of a 3D ultrasound-based neuronavigation system. , 2002, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[9]  Thomas Langø,et al.  Ultrasound Guided Surgery: Image Processing and Navigation , 2000 .

[10]  Ramin Shahidi,et al.  A real-time freehand 3D ultrasound system for image-guided surgery , 2000, 2000 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.00CH37121).

[11]  Yongmin Kim,et al.  Fast calibration for 3D ultrasound imaging and multimodality image registration , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[12]  Hong Chen,et al.  Observing a volume rendered fetus within a pregnant patient , 1994, Proceedings Visualization '94.

[13]  Yoshikazu Nakajima,et al.  Image guidance of breast cancer surgery using 3-D ultrasound images and augmented reality visualization , 1998, IEEE Transactions on Medical Imaging.

[14]  J. Waterton,et al.  Three-dimensional freehand ultrasound: image reconstruction and volume analysis. , 1997, Ultrasound in medicine & biology.

[15]  L G Bouchet,et al.  Calibration of three-dimensional ultrasound images for image-guided radiation therapy. , 2001, Physics in medicine and biology.

[16]  F. Duck Physical properties of tissue , 1990 .

[17]  Shangkai Gao,et al.  A new calibration method in 3D ultrasonic imaging system , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[18]  Terry M. Peters,et al.  Ultrasound Probe Tracking for Real-Time Ultrasound/MRI Overlay and Visualization of Brain Shift , 1999, MICCAI.

[19]  D M Muratore,et al.  Beam calibration without a phantom for creating a 3-D freehand ultrasound system. , 2001, Ultrasound in medicine & biology.

[20]  N Pagoulatos,et al.  A fast calibration method for 3-D tracking of ultrasound images using a spatial localizer. , 2001, Ultrasound in medicine & biology.

[21]  D. Leotta,et al.  Performance of a miniature magnetic position sensor for three-dimensional ultrasound imaging. , 1997, Ultrasound in medicine & biology.

[22]  R W Prager,et al.  Rapid calibration for 3-D freehand ultrasound. , 1998, Ultrasound in medicine & biology.

[23]  G Bashein,et al.  3D ultrasonic image feature localization based on magnetic scanhead tracking: in vitro calibration and validation. , 1994, Ultrasound in medicine & biology.

[24]  E Steen,et al.  Dynamic three-dimensional freehand echocardiography using raw digital ultrasound data. , 1999, Ultrasound in medicine & biology.

[25]  Robert Rohling,et al.  Automatic calibration for 3-D free-hand ultrasound , 1997 .

[26]  Philippe Cinquin,et al.  Using a 3D Position Sensor for Registration of SPECT and US Images of the Kidney , 1995, CVRMed.

[27]  Yongmin Kim,et al.  Interactive 3D registration of ultrasound and magnetic resonance images based on a magnetic position sensor , 1999, IEEE Transactions on Information Technology in Biomedicine.

[28]  K. Paulsen,et al.  Error analysis for a free-hand three-dimensional ultrasound system for neuronavigation , 1999 .

[29]  Warren S. Edwards,et al.  Calibration and validation of freehand 3D ultrasound systems based on DC magnetic tracking , 1998, Medical Imaging.