The helical flow pump with a hydrodynamic levitation impeller

The helical flow pump (HFP) is a novel rotary blood pump invented for developing a total artificial heart (TAH). The HFP with a hydrodynamic levitation impeller, which consists of a multi-vane impeller involving rotor magnets, stator coils at the core position, and double helical-volute pump housing, was developed. Between the stator and impeller, a hydrodynamic bearing is formed. Since the helical volutes are formed at both sides of the impeller, blood flows with a helical flow pattern inside the pump. The developed HFP showed maximum output of 19 l/min against 100 mmHg of pressure head and 11 % maximum efficiency. The profile of the H–Q (pressure head vs. flow) curve was similar to that of the undulation pump. Hydrodynamic levitation of the impeller was possible with higher than 1,000 rpm rotation speed. The normalized index of the hemolysis ratio of the HFP to centrifugal pump (BPX-80) was from 2.61 to 8.07 depending on the design of the bearing. The HFP was implanted in two goats with a left ventricular bypass method. After surgery, hemolysis occurred in both goats. The hemolysis ceased on postoperative days 14 and 9, respectively. In the first experiment, no thrombus was found in the pump after 203 days of pumping. In the second experiment, a white thrombus was found in the pump after 23 days of pumping. While further research and development are necessary, we are expecting to develop an excellent TAH with the HFP.

[1]  C. Cripps Rapid method for the estimation of plasma haemoglobin levels. , 1968, Journal of clinical pathology.

[2]  K Atsumi,et al.  Basic study to develop the undulation pump for practical use: antithrombogenicity, hemolysis, and flow patterns inside the pump. , 1995, Artificial organs.

[3]  S. Steen,et al.  HeartMate left ventricular assist device as bridge to heart transplantation. , 1998, The Annals of thoracic surgery.

[4]  K. Mabuchi,et al.  Physiological control of a total artificial heart: conductance- and arterial pressure-based control. , 1998, Journal of applied physiology.

[5]  M E DeBakey,et al.  A miniature implantable axial flow ventricular assist device. , 1999, The Annals of thoracic surgery.

[6]  C D Bertram,et al.  Computational fluid dynamics analysis of hydrodynamic bearings of the VentrAssist rotary blood pump. , 2000, Artificial organs.

[7]  P M Portner,et al.  Improved outcomes with an implantable left ventricular assist system: a multicenter study. , 2001, The Annals of thoracic surgery.

[8]  J F Antaki,et al.  HeartMate II left ventricular assist system: from concept to first clinical use. , 2001, The Annals of thoracic surgery.

[9]  M C Oz,et al.  Long-term use of a left ventricular assist device for end-stage heart failure. , 2001, The New England journal of medicine.

[10]  J. Copeland,et al.  Comparison of the CardioWest total artificial heart, the novacor left ventricular assist system and the thoratec ventricular assist system in bridge to transplantation. , 2001, The Annals of thoracic surgery.

[11]  S Saito,et al.  Development status of Terumo implantable left ventricular assist system. , 2001, Artificial organs.

[12]  Mitsuo Umezu,et al.  EVAHEART: an implantable centrifugal blood pump for long-term circulatory support. , 2002, The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi.

[13]  O H Frazier,et al.  The AbioCor implantable replacement heart. , 2003, The Annals of thoracic surgery.

[14]  Kiyotaka Fukamachi,et al.  New technologies for mechanical circulatory support: current status and future prospects of CorAide and MagScrew technologies , 2004, Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs.

[15]  O.H. Frazier,et al.  Use of the Flowmaker (Jarvik 2000) Left Ventricular Assist Device for Destination Therapy and Bridging to Transplantation , 2004, Cardiology.

[16]  Yukihiko Nosé,et al.  Current status of the gyro centrifugal blood pump--development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project). , 2004, Artificial organs.

[17]  Setsuo Takatani,et al.  Mechanical circulatory support devices (MCSD) in Japan: current status and future directions , 2005, Journal of Artificial Organs.

[18]  Nong Zhang,et al.  Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump. , 2004, Artificial organs.

[19]  Christoph Schmidt,et al.  First clinical experience with the Incor left ventricular assist device. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[20]  Craig H Selzman,et al.  Current status of the total artificial heart. , 2006, American heart journal.

[21]  J. Kirklin,et al.  Mechanical circulatory support therapy as a bridge to transplant or recovery (new advances) , 2006, Current opinion in cardiology.

[22]  Yusuke Abe,et al.  Development of mechanical circulatory support devices at the University of Tokyo , 2007, Journal of Artificial Organs.

[23]  William E Cohn,et al.  Total Heart Replacement Using Dual Intracorporeal Continuous-Flow Pumps in a Chronic Bovine Model: A Feasibility Study , 2006, ASAIO journal.

[24]  Wei Shi,et al.  A nonpulsatile total artificial heart with 1/R control , 2008, Journal of Artificial Organs.

[25]  Glucose depletion enhances sensitivity to shear stress-induced mechanical damage in red blood cells by rotary blood pumps. , 2009, Artificial organs.

[26]  Ryo Kosaka,et al.  Improvement of hemocompatibility in centrifugal blood pump with hydrodynamic bearings and semi-open impeller: in vitro evaluation. , 2009, Artificial organs.

[27]  Tushar Karkhanis,et al.  Physiologic benefits of pulsatile perfusion during mechanical circulatory support for the treatment of acute and chronic heart failure in adults. , 2010, Artificial organs.

[28]  Kazuhiko Ishihara,et al.  Lubricity and stability of poly(2-methacryloyloxyethyl phosphorylcholine) polymer layer on Co-Cr-Mo surface for hemi-arthroplasty to prevent degeneration of articular cartilage. , 2010, Biomaterials.

[29]  Daniel Tamez,et al.  Design concepts and principle of operation of the HeartWare ventricular assist system. , 2010, ASAIO journal.

[30]  Kiyotaka Fukamachi,et al.  Speed Modulation of the Continuous-Flow Total Artificial Heart to Simulate a Physiologic Arterial Pressure Waveform , 2010, ASAIO journal.

[31]  F. Pagani,et al.  Bridge to Transplantation: Current Outcomes , 2010, Journal of cardiac surgery.

[32]  Mechanical damage of red blood cells by rotary blood pumps : selective destruction of aged red blood cells and subhemolytic trauma , 2010 .

[33]  Wei Shi,et al.  Results of animal experiments with the fourth model of the undulation pump total artificial heart. , 2011, Artificial organs.