The helical flow pump with a hydrodynamic levitation impeller
暂无分享,去创建一个
I. Saito | T. Isoyama | Y. Inoue | K. Ishii | H. Nakagawa | T. Ono | Y. Abe | K. Imachi | E. Nakano | K. Fukazawa | K. Ishihara | K. Fukunaga | M. Ono
[1] C. Cripps. Rapid method for the estimation of plasma haemoglobin levels. , 1968, Journal of clinical pathology.
[2] K Atsumi,et al. Basic study to develop the undulation pump for practical use: antithrombogenicity, hemolysis, and flow patterns inside the pump. , 1995, Artificial organs.
[3] S. Steen,et al. HeartMate left ventricular assist device as bridge to heart transplantation. , 1998, The Annals of thoracic surgery.
[4] K. Mabuchi,et al. Physiological control of a total artificial heart: conductance- and arterial pressure-based control. , 1998, Journal of applied physiology.
[5] M E DeBakey,et al. A miniature implantable axial flow ventricular assist device. , 1999, The Annals of thoracic surgery.
[6] C D Bertram,et al. Computational fluid dynamics analysis of hydrodynamic bearings of the VentrAssist rotary blood pump. , 2000, Artificial organs.
[7] P M Portner,et al. Improved outcomes with an implantable left ventricular assist system: a multicenter study. , 2001, The Annals of thoracic surgery.
[8] J F Antaki,et al. HeartMate II left ventricular assist system: from concept to first clinical use. , 2001, The Annals of thoracic surgery.
[9] M C Oz,et al. Long-term use of a left ventricular assist device for end-stage heart failure. , 2001, The New England journal of medicine.
[10] J. Copeland,et al. Comparison of the CardioWest total artificial heart, the novacor left ventricular assist system and the thoratec ventricular assist system in bridge to transplantation. , 2001, The Annals of thoracic surgery.
[11] S Saito,et al. Development status of Terumo implantable left ventricular assist system. , 2001, Artificial organs.
[12] Mitsuo Umezu,et al. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support. , 2002, The Japanese journal of thoracic and cardiovascular surgery : official publication of the Japanese Association for Thoracic Surgery = Nihon Kyobu Geka Gakkai zasshi.
[13] O H Frazier,et al. The AbioCor implantable replacement heart. , 2003, The Annals of thoracic surgery.
[14] Kiyotaka Fukamachi,et al. New technologies for mechanical circulatory support: current status and future prospects of CorAide and MagScrew technologies , 2004, Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs.
[15] O.H. Frazier,et al. Use of the Flowmaker (Jarvik 2000) Left Ventricular Assist Device for Destination Therapy and Bridging to Transplantation , 2004, Cardiology.
[16] Yukihiko Nosé,et al. Current status of the gyro centrifugal blood pump--development of the permanently implantable centrifugal blood pump as a biventricular assist device (NEDO project). , 2004, Artificial organs.
[17] Setsuo Takatani,et al. Mechanical circulatory support devices (MCSD) in Japan: current status and future directions , 2005, Journal of Artificial Organs.
[18] Nong Zhang,et al. Experimental determination of dynamic characteristics of the VentrAssist implantable rotary blood pump. , 2004, Artificial organs.
[19] Christoph Schmidt,et al. First clinical experience with the Incor left ventricular assist device. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.
[20] Craig H Selzman,et al. Current status of the total artificial heart. , 2006, American heart journal.
[21] J. Kirklin,et al. Mechanical circulatory support therapy as a bridge to transplant or recovery (new advances) , 2006, Current opinion in cardiology.
[22] Yusuke Abe,et al. Development of mechanical circulatory support devices at the University of Tokyo , 2007, Journal of Artificial Organs.
[23] William E Cohn,et al. Total Heart Replacement Using Dual Intracorporeal Continuous-Flow Pumps in a Chronic Bovine Model: A Feasibility Study , 2006, ASAIO journal.
[24] Wei Shi,et al. A nonpulsatile total artificial heart with 1/R control , 2008, Journal of Artificial Organs.
[25] Glucose depletion enhances sensitivity to shear stress-induced mechanical damage in red blood cells by rotary blood pumps. , 2009, Artificial organs.
[26] Ryo Kosaka,et al. Improvement of hemocompatibility in centrifugal blood pump with hydrodynamic bearings and semi-open impeller: in vitro evaluation. , 2009, Artificial organs.
[27] Tushar Karkhanis,et al. Physiologic benefits of pulsatile perfusion during mechanical circulatory support for the treatment of acute and chronic heart failure in adults. , 2010, Artificial organs.
[28] Kazuhiko Ishihara,et al. Lubricity and stability of poly(2-methacryloyloxyethyl phosphorylcholine) polymer layer on Co-Cr-Mo surface for hemi-arthroplasty to prevent degeneration of articular cartilage. , 2010, Biomaterials.
[29] Daniel Tamez,et al. Design concepts and principle of operation of the HeartWare ventricular assist system. , 2010, ASAIO journal.
[30] Kiyotaka Fukamachi,et al. Speed Modulation of the Continuous-Flow Total Artificial Heart to Simulate a Physiologic Arterial Pressure Waveform , 2010, ASAIO journal.
[31] F. Pagani,et al. Bridge to Transplantation: Current Outcomes , 2010, Journal of cardiac surgery.
[33] Wei Shi,et al. Results of animal experiments with the fourth model of the undulation pump total artificial heart. , 2011, Artificial organs.