Leveraging Blur Information for Plenoptic Camera Calibration

This paper presents a novel calibration algorithm for plenoptic cameras, especially the multi-focus configuration, where several types of micro-lenses are used, using raw images only. Current calibration methods rely on simplified projection models, use features from reconstructed images, or require separated calibrations for each type of micro-lens. In the multi-focus configuration, the same part of a scene will demonstrate different amounts of blur according to the micro-lens focal length. Usually, only micro-images with the smallest amount of blur are used. In order to exploit all available data, we propose to explicitly model the defocus blur in a new camera model with the help of our newly introduced Blur Aware Plenoptic (BAP) feature. First, it is used in a pre-calibration step that retrieves initial camera parameters, and second, to express a new cost function to be minimized in our single optimization process. Third, it is exploited to calibrate the relative blur between micro-images. It links This work was supported by the AURA Region and the European Union (FEDER) through the MMII project of CPER 2015-2020 MMaSyF challenge. Mathieu Labussière1 orcid.org/0000-0001-8105-4139 E-mail: mathieu.labu@gmail.com Céline Teulière1 orcid.org/0000-0002-8857-5524 E-mail: celine.teuliere@uca.fr Frédéric Bernardin2 orcid.org/0000-0002-1248-153X E-mail: frederic.bernardin@cerema.fr Omar Ait-Aider1 orcid.org/0000-0002-1711-187X E-mail: omar.ait-aider@uca.fr 1 Université Clermont Auvergne, Clermont Auvergne INP, CNRS, Institut Pascal, F-63000 Clermont-Ferrand, France 2 Cerema, Équipe-projet STI, 10 rue Bernard Palissy, F-63017 ClermontFerrand, France the geometric blur, i.e., the blur circle, to the physical blur, i.e., the point spread function. Finally, we use the resulting blur profile to characterize the camera’s depth of field. Quantitative evaluations in controlled environment on real-world data demonstrate the effectiveness of our calibrations.

[1]  Ping Zhou,et al.  A two-step calibration method of lenslet-based light field cameras , 2019 .

[2]  Michel Dhome,et al.  Light-Field Camera Calibration from Raw Images , 2017, 2017 International Conference on Digital Image Computing: Techniques and Applications (DICTA).

[3]  Tom E. Bishop,et al.  The Light Field Camera: Extended Depth of Field, Aliasing, and Superresolution , 2012, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[4]  Uwe Stilla,et al.  Calibration and accuracy analysis of a focused plenoptic camera , 2014 .

[5]  Hui Zhou,et al.  Blur-Aware Disparity Estimation from Defocus Stereo Images , 2015, 2015 IEEE International Conference on Computer Vision (ICCV).

[6]  Lennart Wietzke,et al.  Single lens 3D-camera with extended depth-of-field , 2012, Electronic Imaging.

[7]  Andrew Lumsdaine,et al.  Resolution in Plenoptic Cameras , 2009 .

[8]  Stefan B. Williams,et al.  Decoding, Calibration and Rectification for Lenselet-Based Plenoptic Cameras , 2013, 2013 IEEE Conference on Computer Vision and Pattern Recognition.

[9]  Uwe Stilla,et al.  METRIC CALIBRATION OF A FOCUSED PLENOPTIC CAMERA BASED ON A 3D CALIBRATION TARGET , 2016 .

[10]  Shengxian Shi,et al.  Metric calibration of unfocused plenoptic cameras for three-dimensional shape measurement , 2020 .

[11]  W. Freeman,et al.  Understanding Camera Trade-Offs through a Bayesian Analysis of Light Field Projections , 2008, ECCV.

[12]  Murali Subbarao,et al.  Determining Distance from Defocused Images of Simple Objects , 1999 .

[13]  Stephan Hussmann,et al.  Automated Robust Metric Calibration Algorithm for Multifocus Plenoptic Cameras , 2016, IEEE Transactions on Instrumentation and Measurement.

[14]  Uwe Stilla,et al.  Investigating mathematical models for focused plenoptic cameras , 2016, 2016 12th IEEE International Symposium on Electronics and Telecommunications (ISETC).

[15]  P. Hanrahan,et al.  Light Field Photography with a Hand-held Plenoptic Camera , 2005 .

[16]  Murali Subbarao Parallel Depth Recovery By Changing Camera Parameters , 1988, [1988 Proceedings] Second International Conference on Computer Vision.

[17]  Michael S. Langer,et al.  What is a Good Model for Depth from Defocus? , 2016, 2016 13th Conference on Computer and Robot Vision (CRV).

[18]  Brian S. Thurow,et al.  Calibration of a Microlens Array for a Plenoptic Camera , 2014 .

[19]  Peter Lawrence,et al.  An Investigation of Methods for Determining Depth from Focus , 1993, IEEE Trans. Pattern Anal. Mach. Intell..

[20]  In-So Kweon,et al.  Geometric Calibration of Micro-Lens-Based Light Field Cameras Using Line Features , 2014, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[21]  David Salesin,et al.  Spatio-angular resolution tradeoffs in integral photography , 2006, EGSR '06.

[22]  Michael S. Langer,et al.  Blur Calibration for Depth from Defocus , 2016, 2016 13th Conference on Computer and Robot Vision (CRV).

[23]  Shengxian Shi,et al.  Parametric study on light field volumetric particle image velocimetry , 2016 .

[24]  Bastian Goldlücke,et al.  On the Calibration of Focused Plenoptic Cameras , 2013, Time-of-Flight and Depth Imaging.

[25]  Roland Siegwart,et al.  A novel parametrization of the perspective-three-point problem for a direct computation of absolute camera position and orientation , 2011, CVPR 2011.

[26]  Shree K. Nayar,et al.  The Raxel Imaging Model and Ray-Based Calibration , 2005, International Journal of Computer Vision.

[27]  Murali Subbarao,et al.  Depth from defocus: A spatial domain approach , 1994, International Journal of Computer Vision.

[28]  Uwe Stilla,et al.  From the Calibration of a Light-Field Camera to Direct Plenoptic Odometry , 2017, IEEE Journal of Selected Topics in Signal Processing.

[29]  Andrew Lumsdaine,et al.  Depth of Field in Plenoptic Cameras , 2009, Eurographics.

[30]  Reinhard Koch,et al.  Optimizing the Lens Selection Process for Multi-focus Plenoptic Cameras and Numerical Evaluation , 2017, 2017 IEEE Conference on Computer Vision and Pattern Recognition Workshops (CVPRW).

[31]  Omar Ait-Aider,et al.  Blur Aware Calibration of Multi-Focus Plenoptic Camera , 2020, 2020 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR).

[32]  Andrew Lumsdaine,et al.  The focused plenoptic camera , 2009, 2009 IEEE International Conference on Computational Photography (ICCP).

[33]  Shing-Chow Chan,et al.  Light Field , 2014, Computer Vision, A Reference Guide.

[34]  Alex Pentland,et al.  A New Sense for Depth of Field , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[35]  Klaus H. Strobl,et al.  Stepwise calibration of focused plenoptic cameras , 2016, Comput. Vis. Image Underst..

[36]  Hans-Peter Kriegel,et al.  A Density-Based Algorithm for Discovering Clusters in Large Spatial Databases with Noise , 1996, KDD.

[37]  Robert E. Mahony,et al.  Calibrating Light-Field Cameras Using Plenoptic Disc Features , 2018, 2018 International Conference on 3D Vision (3DV).

[38]  In-So Kweon,et al.  A Taxonomy and Evaluation of Dense Light Field Depth Estimation Algorithms , 2017, 2017 IEEE Conference on Computer Vision and Pattern Recognition Workshops (CVPRW).

[39]  Marc Levoy,et al.  Light field rendering , 1996, SIGGRAPH.

[40]  Vladan Velisavljevic,et al.  Baseline and Triangulation Geometry in a Standard Plenoptic Camera , 2017, International Journal of Computer Vision.

[41]  Ivo Ihrke,et al.  A Unifying First-Order Model for Light-Field Cameras: The Equivalent Camera Array , 2017, IEEE Transactions on Computational Imaging.

[42]  Qing Wang,et al.  A Generic Multi-Projection-Center Model and Calibration Method for Light Field Cameras , 2018, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[43]  Sébastien Ourselin,et al.  Corner-Based Geometric Calibration of Multi-focus Plenoptic Cameras , 2017, 2017 IEEE International Conference on Computer Vision (ICCV).

[44]  Di He,et al.  Virtual Image Points Based Geometrical Parameters’ Calibration for Focused Light Field Camera , 2018, IEEE Access.

[45]  Qing Wang,et al.  Unconstrained Two-parallel-plane Model for Focused Plenoptic Cameras Calibration , 2016, ArXiv.

[46]  Tomasz Wrona,et al.  Microlens array calibration method for a light field camera , 2018, 2018 19th International Carpathian Control Conference (ICCC).