A multi-element interstitial ultrasound applicator for the thermal therapy of brain tumors.

Interstitial thermal therapy is a minimally invasive treatment modality that has been used clinically for ablating both primary and secondary brain tumors. Here a multi-element interstitial ultrasound applicator is described that allows for increased spatial control during thermal ablation of tumors as compared to existing clinical devices. The device consists of an array of 56 ultrasound elements operating at 6 MHz, oriented on the seven faces of a 3.2 mm flexible catheter. The device was first characterized using the acoustic holography method to examine the functioning of the array. Then experiments were performed to measure heating in tissue-mimicking gel phantoms and ex vivo tissue samples using magnetic resonance imaging-based thermometry. Experimental measurements were compared with results obtained using numerical simulations. Last, simulations were performed to study the feasibility of using the device for thermal ablation in the brain. Experimental results show that the device can be used to induce a temperature rise of greater than 20 °C in ex vivo tissue samples and numerical simulations further demonstrate that tumors with diameters of greater than 30-mm could potentially be treated.

[1]  S. Maier,et al.  MAGNETIC RESONANCE IMAGING‐GUIDED, HIGH‐INTENSITY FOCUSED ULTRASOUND FOR BRAIN TUMOR THERAPY , 2006, Neurosurgery.

[2]  Eric Vicaut,et al.  Real-time magnetic resonance-guided laser thermal therapy for focal metastatic brain tumors. , 2008, Neurosurgery.

[3]  Cyril Lafon,et al.  Transoesophageal ultrasound applicator for sector-based thermal ablation: first in vivo experiments. , 2003, Ultrasound in medicine & biology.

[4]  F. Dunn,et al.  Comprehensive compilation of empirical ultrasonic properties of mammalian tissues. , 1978, The Journal of the Acoustical Society of America.

[5]  Vesna Zderic,et al.  Gel phantom for use in high-intensity focused ultrasound dosimetry. , 2005, Ultrasound in medicine & biology.

[6]  Gene H. Barnett,et al.  Laser Interstitial Thermal Therapy for Focal Cerebral Radiation Necrosis: A Case Report and Literature Review , 2012, Stereotactic and Functional Neurosurgery.

[7]  John D Hazle,et al.  Quantitative comparison of thermal dose models in normal canine brain. , 2010, Medical physics.

[8]  Carl D. Herickhoff,et al.  Dual-Mode Intracranial Catheter Integrating 3D Ultrasound Imaging and Hyperthermia for Neuro-oncology: Feasibility Study , 2009, Ultrasonic imaging.

[9]  Francis A. Duck,et al.  Thermal Properties of Tissue , 1990 .

[10]  Francis A. Duck,et al.  Physical properties of tissue : a comprehensive reference book , 1990 .

[11]  R. Stafford,et al.  Multiplanar MR temperature‐sensitive imaging of cerebral thermal treatment using interstitial ultrasound applicators in a canine model , 2002, Journal of magnetic resonance imaging : JMRI.

[12]  Bruno Quesson,et al.  Magnetic resonance temperature imaging for guidance of thermotherapy , 2000, Journal of magnetic resonance imaging : JMRI.

[13]  R. Lufkin,et al.  Preliminary experience with MR-guided thermal ablation of brain tumors. , 1995, AJNR. American journal of neuroradiology.

[14]  Rares Salomir,et al.  Automatic temperature control for MR‐guided interstitial ultrasound ablation in liver using a percutaneous applicator: Ex vivo and in vivo initial studies , 2010, Magnetic resonance in medicine.

[15]  Ralph W. Barnes,et al.  Ultrasonic attenuation and propagation speed in normal human brain , 1981 .

[16]  K. Hynynen,et al.  Transcranial Magnetic Resonance Imaging– Guided Focused Ultrasound Surgery of Brain Tumors: Initial Findings in 3 Patients , 2010, Neurosurgery.

[17]  Jean-Yves Delattre,et al.  MR‐guided laser‐induced thermal therapy (LITT) for recurrent glioblastomas , 2012, Lasers in surgery and medicine.

[18]  K. Hynynen,et al.  MRI investigation of the threshold for thermally induced blood–brain barrier disruption and brain tissue damage in the rabbit brain , 2004, Magnetic resonance in medicine.

[19]  E. Glatstein MR-guided laser-induced interstitial thermotherapy of recurrent glioblastoma multiforme: Preliminary results in 16 patients , 2008 .

[20]  Jean-Yves Chapelon,et al.  In Vivo Evaluation of a Mechanically Oscillating Dual-Mode Applicator for Ultrasound Imaging and Thermal Ablation , 2010, IEEE Transactions on Biomedical Engineering.

[21]  S.W. Smith,et al.  Integrated catheter for 3-d intracardiac echo cardiography and ultrasound ablation , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  Eric C Leuthardt,et al.  Magnetic Resonance Imaging-Guided Focused Laser Interstitial Thermal Therapy for Subinsular Metastatic Adenocarcinoma: Technical Case Report , 2012, Neurosurgery.

[23]  Shabbar F Danish,et al.  Magnetic Resonance Thermometry-Guided Laser-Induced Thermal Therapy for Intracranial Neoplasms: Initial Experience , 2012, Neurosurgery.

[24]  T. D. Mast,et al.  Bulk ablation of soft tissue with intense ultrasound: modeling and experiments. , 2005, The Journal of the Acoustical Society of America.

[25]  C. Moonen,et al.  64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: an ex vivo study. , 2006, Medical physics.

[26]  E. Burdette,et al.  Combination of transurethral and interstitial ultrasound applicators for high-temperature prostate thermal therapy , 2000, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[27]  D. Melodelima,et al.  Interstitial devices for minimally invasive thermal ablation by high-intensity ultrasound , 2007, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[28]  Marko Kangasniemi,et al.  Interleaved echo‐planar imaging for fast multiplanar magnetic resonance temperature imaging of ultrasound thermal ablation therapy , 2004, Journal of magnetic resonance imaging : JMRI.

[29]  Kenneth I Marro,et al.  Magnetic resonance imaging of boiling induced by high intensity focused ultrasound. , 2007, The Journal of the Acoustical Society of America.

[30]  Treatment of rabbit liver cancer in vivo using miniaturized image-ablate ultrasound arrays. , 2011, Ultrasound in medicine & biology.

[31]  C. Lafon,et al.  Design and preliminary results of an ultrasound applicator for interstitial thermal coagulation. , 1998, Ultrasound in medicine & biology.

[32]  Kim Butts,et al.  Study of laser ablation in the in vivo rabbit brain with MR thermometry , 2002, Journal of magnetic resonance imaging : JMRI.

[33]  N. McDannold Quantitative MRI-based temperature mapping based on the proton resonant frequency shift: Review of validation studies , 2005, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[34]  M. Bronskill,et al.  Multifrequency ultrasound transducers for conformal interstitial thermal therapy , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[35]  M. Bronskill,et al.  MRI-guided transurethral ultrasound therapy of the prostate gland using real-time thermal mapping: initial studies. , 2010, Urology.

[36]  C. Prestigiacomo,et al.  117 Digital Substraction Angiography in CT Angiography Negative Spontaneous Subarachnoid Hemorrhage. , 2012, Neurosurgery.

[37]  A. V. Morozov,et al.  Reconstruction of the normal velocity distribution on the surface of an ultrasonic transducer from the acoustic pressure measured on a reference surface , 2003 .

[38]  Clement,et al.  Field characterization of therapeutic ultrasound phased arrays through forward and backward planar projection , 2000, The Journal of the Acoustical Society of America.

[39]  Rajiv Chopra,et al.  MRI-compatible transurethral ultrasound system for the treatment of localized prostate cancer using rotational control. , 2008, Medical physics.

[40]  P. Cornu,et al.  MR-Guided LITT for Recurrent Glioblastomas , 2012 .

[41]  Fabrice Marquet,et al.  In vivo transcranial brain surgery with an ultrasonic time reversal mirror. , 2007, Journal of neurosurgery.

[42]  K. Hynynen,et al.  Optimization of spoiled gradient‐echo phase imaging for in vivo localization of a focused ultrasound beam , 1996, Magnetic resonance in medicine.

[43]  M. Bronskill,et al.  Feasibility of linear arrays for interstitial ultrasound thermal therapy. , 2000, Medical physics.