Preliminary Results of Tibial Bone Transports With Pulsed Low Intensity Ultrasound (Exogen™)

Objective: This study assessed whether the use of noninvasive, pulsed low intensity ultrasound (Exogen™) reduced external fixation time for bone transport patients with large, segmental tibial defects. Design: This was a prospective study compared to a previously treated control group. Setting: All surgeries and postoperative care were done at the senior author's hospital facilities. Patients/Participants: Eight patients with large tibial segmental defects, acute or chronic, were studied. All patients were male, mean age 34 years (range 18-50). Intervention: All patients were treated with a single-level bone transport. Bone transports started 5 to 10 days after a metaphyseal corticotomy and progressed with one-quarter millimeter advancement 2 to 4 times per day. Exogen was applied to the regenerate site in the second postoperative week and to the docking site after docking was complete. The treatment was used for 20 minutes daily at each site. The patients were followed weekly for the first 4 weeks. They were then followed bimonthly for 2 months and then monthly until consolidation had occurred. Main Outcome Measures: The 2 main outcome measures used were the external fixation time measured in months and the external fixation index (time in the frame per cm of bone transported) measured in months per cm. Results: The mean follow-up from frame removal to the time of the last clinic visit was 12.4 months (range 4-32). The mean external fixation time was 13.91. The mean external fixation index was 1.34 months per cm transported for the Exogen group and 2.02 months per cm for the control group. Although not statistically significant because of small numbers, the external fixation index was reduced by 17.21%. Conclusion: These data further confirm already published data on the acceleration of fracture healing by low intensity pulsed ultrasound and, in our case, regenerate consolidation. Shorter treatment periods reduce complications and expenses and return patients back to regular activities more quickly.

[1]  Edward Abraham,et al.  Bone transport in the management of posttraumatic bone defects in the lower extremity. , 2004, The Journal of trauma.

[2]  Lynne E Bilston,et al.  Low-Intensity Ultrasound Stimulation in Distraction Osteogenesis in Rabbits , 2003, Clinical orthopaedics and related research.

[3]  H. Kreder,et al.  The Effect of Smoking on Clinical Outcome and Complication Rates Following Ilizarov Reconstruction , 2003, Journal of orthopaedic trauma.

[4]  S. Gold,et al.  Ten year experience with use of Ilizarov bone transport for tibial defects. , 2003, Bulletin (Hospital for Joint Diseases (New York, N.Y.)).

[5]  P. Ostermann,et al.  Management of a long segmental defect at the proximal meta-diaphyseal junction of the tibia using a cylindrical titanium mesh cage. , 2002, Journal of orthopaedic trauma.

[6]  M. Bhandari,et al.  The effect of low-intensity pulsed ultrasound therapy on time to fracture healing: a meta-analysis. , 2002, CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne.

[7]  J. Ryaby,et al.  Low-intensity pulsed ultrasound in the treatment of nonunions. , 2001, The Journal of trauma.

[8]  D. Paley,et al.  Ilizarov bone transport treatment for tibial defects. , 2000, Journal of orthopaedic trauma.

[9]  R. Atkins,et al.  Ipsilateral vascularised fibular transport for massive defects of the tibia. , 1999, The Journal of bone and joint surgery. British volume.

[10]  K. Koo,et al.  Tibial bone defects treated by internal bone transport using the Ilizarov method , 1998, International Orthopaedics.

[11]  L. Yi,et al.  One-stage open cancellous bone grafting of infected fracture and nonunion , 1998, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[12]  D. Marsh,et al.  The Ilizarov method in nonunion, malunion and infection of fractures. , 1997, The Journal of bone and joint surgery. British volume.

[13]  R. Feibel,et al.  Combined Muscle Flap and Ilizarov Reconstruction for Bone and Soft Tissue Defects , 1996, Clinical orthopaedics and related research.

[14]  J. Watson,et al.  Management strategies for bone loss in tibial shaft fractures. , 1995, Clinical orthopaedics and related research.

[15]  G. Dendrinos,et al.  Use of the Ilizarov technique for treatment of non-union of the tibia associated with infection. , 1995, The Journal of bone and joint surgery. American volume.

[16]  L. Naggar,et al.  Treatment of large bone defects with the Ilizarov technique. , 1993, The Journal of trauma.

[17]  E. E. Johnson,et al.  The treatment of infected nonunions and segmental defects of the tibia by the methods of Ilizarov. , 1992, Clinical orthopaedics and related research.

[18]  F. Dagher,et al.  Compound tibial fractures with bone loss treated by the Ilizarov technique. , 1991, The Journal of bone and joint surgery. British volume.

[19]  A. Pilla,et al.  Non-invasive low-intensity pulsed ultrasound accelerates bone healing in the rabbit. , 1990, Journal of orthopaedic trauma.

[20]  D. Paley,et al.  Problems, obstacles, and complications of limb lengthening by the Ilizarov technique. , 1990, Clinical orthopaedics and related research.