Point-of-Care Assay of Telomerase Activity at Single-Cell Level via Gas Pressure Readout.

Detection of telomerase activity at the single-cell level is one of the central challenges in cancer diagnostics and therapy. Herein, we describe a facile and reliable point-of-care testing (POCT) strategy for detection of telomerase activity via a portable pressure meter. Telomerase primer (TS) was immobilized onto the surface of magnetic beads (MBs), and then was elongated to a long single-stranded DNA by telomerase. The elongated (TTAGGG)n repeat unit hybridized with several short PtNP-functionalized complementary DNA (PtNPs-cDNA), which specifically enriched PtNPs onto the surfaces of magnetic beads (MBs), which were separated using a magnet. Then, nanoparticle-catalyzed gas-generation reaction converted telomerase activity into significant change in gas pressure. Because of the self-amplification of telomerase and enrichment by magnetic separation, the diluted telomerase equivalent to a single HeLa cell was facilely detected. More importantly, the telomerase in the lysate of 1 HeLa cell can be reliably detected by monitoring change in gas pressure, indicating that it is feasible and possible to study differences between individual cells. The difference in relative activity between different kinds of cancer cells was easily and sensitively studied. Study of inhibition of telomerase activity demonstrated that our method has great potential in screening of telomerase-targeted antitumor drugs as well as in clinical diagnosis.

[1]  Ying Li,et al.  Highly sensitive electrochemical detection of human telomerase activity based on bio-barcode method. , 2010, Biosensors & bioelectronics.

[2]  Gregory G. Lewis,et al.  Quantifying analytes in paper-based microfluidic devices without using external electronic readers. , 2012, Angewandte Chemie.

[3]  T. Cech,et al.  dGTP-dependent processivity and possible template switching of euplotes telomerase. , 1997, Nucleic acids research.

[4]  Minghua Lu,et al.  Wrapping DNA-gated mesoporous silica nanoparticles for quantitative monitoring of telomerase activity with glucometer readout. , 2014, Journal of materials chemistry. B.

[5]  Hongyuan Chen,et al.  Visual electrochemiluminescence detection of telomerase activity based on multifunctional Au nanoparticles modified with G-quadruplex deoxyribozyme and luminol. , 2014, Chemical communications.

[6]  A. Bard,et al.  DNA analysis by application of Pt nanoparticle electrochemical amplification with single label response. , 2012, Journal of the American Chemical Society.

[7]  Hongyuan Chen,et al.  Signal-on dual-potential electrochemiluminescence based on luminol-gold bifunctional nanoparticles for telomerase detection. , 2014, Analytical chemistry.

[8]  Yan Jin,et al.  A PCR-free fluorescence strategy for detecting telomerase activity via double amplification strategy. , 2016, Biosensors & bioelectronics.

[9]  I. Willner,et al.  Magneto-mechanical detection of nucleic acids and telomerase activity in cancer cells. , 2004, Journal of the American Chemical Society.

[10]  Jing Zheng,et al.  SERS assay of telomerase activity at single-cell level and colon cancer tissues via quadratic signal amplification. , 2016, Biosensors & bioelectronics.

[11]  C B Harley,et al.  Telomerase catalytic subunit homologs from fission yeast and human. , 1997, Science.

[12]  W. Pan,et al.  Exonuclease I manipulating primer-modified gold nanoparticles for colorimetric telomerase activity assay. , 2016, Biosensors & bioelectronics.

[13]  Gengfeng Zheng,et al.  Multiplexed electrical detection of cancer markers with nanowire sensor arrays , 2005, Nature Biotechnology.

[14]  Zhi Zhu,et al.  Translating Molecular Recognition into a Pressure Signal to enable Rapid, Sensitive, and Portable Biomedical Analysis. , 2015, Angewandte Chemie.

[15]  Yan Jin,et al.  PCR-free and label-free fluorescent detection of telomerase activity at single-cell level based on triple amplification. , 2016, Biosensors & bioelectronics.

[16]  Yan Jin,et al.  Homogeneous and ultrasensitive detection of telomerase activity via gold nanorod-based fluorescence resonance energy transfer. , 2016, The Analyst.

[17]  Zhengping Li,et al.  Ultrasensitive detection of telomerase activity in a single cell using stem-loop primer-mediated exponential amplification (SPEA) with near zero nonspecific signal† †Electronic supplementary information (ESI) available. See DOI: 10.1039/c6sc00802j , 2016, Chemical science.

[18]  Ben Zhong Tang,et al.  Real-Time, Quantitative Lighting-up Detection of Telomerase in Urines of Bladder Cancer Patients by AIEgens. , 2015, Analytical chemistry.

[19]  Bernhard Sonnleitner,et al.  Automated measurement and monitoring of bioprocesses: key elements of the M(3)C strategy. , 2013, Advances in biochemical engineering/biotechnology.

[20]  Qi Zhang,et al.  Input-dependent induction of G-quadruplex formation for detection of lead (II) by fluorescent ion logic gate. , 2013, Biosensors & bioelectronics.

[21]  Charles S Henry,et al.  Simple, distance-based measurement for paper analytical devices. , 2013, Lab on a chip.

[22]  Bin Chen,et al.  Quencher group induced high specificity detection of telomerase in clear and bloody urines by AIEgens. , 2015, Analytical chemistry.

[23]  Baoxin Li,et al.  Exonuclease III-Assisted Target Recycling Amplification Coupled with Liposome-Assisted Amplification: One-Step and Dual-Amplification Strategy for Highly Sensitive Fluorescence Detection of DNA. , 2015, Analytical chemistry.

[24]  Zhi Zhu,et al.  A pressure-based bioassay for the rapid, portable and quantitative detection of C-reactive protein. , 2016, Chemical communications.

[25]  Huangxian Ju,et al.  Smart vesicle kit for in situ monitoring of intracellular telomerase activity using a telomerase-responsive probe. , 2014, Analytical chemistry.

[26]  X. Qu,et al.  A Pt-nanoparticle electrocatalytic assay used for PCR-free sensitive telomerase detection. , 2013, Chemical communications.

[27]  Chun-yang Zhang,et al.  Ultrasensitive detection of telomerase activity at the single-cell level. , 2013, Analytical chemistry.

[28]  Xiaoling Liang,et al.  Portable and quantitative monitoring of mercury ions using DNA-gated mesoporous silica nanoparticles using a glucometer readout. , 2016, Chemical communications.