The micro-mechanical properties of ion irradiated tungsten

Micro-mechanical testing techniques have proved successful in extracting the properties of bulk materials from small-scale tests. In particular, focussed ion beam (FIB)-machined micro-cantilevers have been shown to produce quantitative, accurate modulus values when used on materials such as pure copper or silicon. In this work, this technique is extended to study the micro-mechanical properties of ion-irradiated, commercially pure tungsten. Ion irradiation has been used to model the cascade damage produced by fusion neutrons in tungsten. Due to the small depth of ion-implanted layers, micro-mechanical tests must be carried out to determine the mechanical properties of the material. These cantilever tests and additional nanoindentation produces data comparable with literature data. An increase in hardness after implantation is measured, while the yield stress of the material remains unchanged. Helium implantation has an effect on the mechanical properties of tungsten. It is hypothesized that this is due to a change in the damage formed under irradiation, from dislocation loops formed in self-ion irradiation to helium-filled vacancies in simultaneous irradiation.

[1]  C. Ronning,et al.  Ion beam irradiation of nanostructures: sputtering, dopant incorporation, and dynamic annealing , 2015 .

[2]  G. Talut,et al.  Dual beam irradiation of nanostructured FeCrAl oxide dispersion strengthened steel , 2011 .

[3]  Jicheng Gong,et al.  Anisotropy in the plastic flow properties of single-crystal α titanium determined from micro-cantilever beams , 2009 .

[4]  A. Wilkinson,et al.  Measuring anisotropy in Young’s modulus of copper using microcantilever testing , 2009 .

[5]  Karen Willcox,et al.  Kinetics and kinematics for translational motions in microgravity during parabolic flight. , 2009, Aviation, space, and environmental medicine.

[6]  Charlotte Becquart,et al.  A density functional theory assessment of the clustering behaviour of He and H in tungsten , 2009 .

[7]  D. Armstrong,et al.  Nanoindentation and Micromechanical Testing of Iron-Chromium Alloys Implanted with Iron Ions , 2008 .

[8]  T. Ihli,et al.  Development of a helium-cooled divertor: Material choice and technological studies , 2007 .

[9]  D. Maio,et al.  Erratum to: Measuring fracture toughness of coatings using focused-ion-beam-machined microbeams , 2005 .

[10]  M. Meyers,et al.  EFFECT OF STRAIN RATE ON PLASTIC FLOW AND FAILURE IN POLYCRYSTALLINE TUNGSTEN , 1998 .

[11]  G. Pharr,et al.  An improved technique for determining hardness and elastic modulus using load and displacement sensing indentation experiments , 1992 .

[12]  D. Armstrong,et al.  Hardening of self ion implanted tungsten and tungsten 5-wt% rhenium , 2013 .