Improvements of Cloud Particle Sizing with a 2D-Grey Probe

Abstract The potential of the 2D-Grey optical array probe (OAP) (with 10-μm resolution) to determine cloud microphysical properties is studied. Systematic test measurements with a spinning glass disk with sample spots of various sizes between 50 and 500 μm in diameter were conducted. These measurements show that the particle image diameter increases considerably if the particle crosses the illuminating laser beam at increasing distance from the object plane. Eventually, shadow images of the smaller spots lose even their circular image shape and appear fragmented. A method is proposed to improve the estimation of the nominal particle size of droplets from the recorded image by exploiting the four available shadow (grey) levels. Laboratory tests show that spherical particles from 50 to 500 μm in diameter can be properly sized with an rms uncertainty of less than 6%. After discussion of the concept of depth of field in OAPs, a definition for the 2D-Grey probe is presented that is consistent with the standard...