EBT2 radiochromic film for quality assurance of complex IMRT treatments of the prostate: micro-collimated IMRT, RapidArc, and TomoTherapy

In response to the clinical need for a dosimetry system with both high resolution and minimal angular dependence, this study demonstrates the utility of Gafchromic EBT2 radiochromic dosimetry film for the quality assurance of micro-collimated IMRT, RapidArc and TomoTherapy treatments. Firstly, preliminary measurements indicated that the dose response of EBT2 film does not appreciably vary with either the angle of incidence of the radiation beam or the depth in water at which the film is placed. Secondly, prostate treatment plans designed for delivery using static-beam IMRT (collimated using the BrainLab m3 microMLC), RapidArc and TomoTherapy were investigated by comparing dose planes obtained from treatment planning calculations with EBT2 film measurements. For all treatment plans, the proportion of dose points agreeing with the film measurements to within γ (3%,3 mm) was found to be above 95%, with all points agreeing within 5%. The film images provided sufficient information to verify that the treatments could be delivered with an acceptable level of accuracy, while also providing additional information on low-level dose variations that were not predicted by the treatment planning systems. This information included: the location and extent of dose from inter-leaf leakage (in the RapidArc plan) and helical field junctioning (in the TomoTherapy plan), as well as the existence of small regions where the treatment planning system under-predicted the dose from very small treatment segments (in the micro-collimated IMRT plan).

[1]  T. Kairn,et al.  Evaluation of a Gafchromic EBT2 film dosimetry system for radiotherapy quality assurance , 2011, Australasian Physical & Engineering Sciences in Medicine.

[2]  N Hodapp,et al.  [The ICRU Report 83: prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)]. , 2012, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al].

[3]  T Kairn,et al.  Adapting a generic BEAMnrc model of the BrainLAB m3 micro-multileaf collimator to simulate a local collimation device , 2010, Physics in medicine and biology.

[4]  S. Fletcher,et al.  Evaluation and optimization of the new EBT2 radiochromic film dosimetry system for patient dose verification in radiotherapy , 2010, Physics in medicine and biology.

[5]  W. Tomé,et al.  Dosimetric verification of helical tomotherapy for total scalp irradiation. , 2008, Medical physics.

[6]  Oliver Jäkel,et al.  Technical Note: Homogeneity of Gafchromic® EBT2 film , 2010 .

[7]  H. Patrocinio,et al.  Searching for optimal dose-volume constraints to reduce rectal toxicity after hypofractionated radiotherapy for prostate cancer. , 2010, Clinical oncology (Royal College of Radiologists (Great Britain)).

[8]  R Jeraj,et al.  The helical tomotherapy thread effect. , 2005, Medical physics.

[9]  M. Gillin,et al.  Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies. , 2010, Medical physics.

[10]  T Kairn,et al.  Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution. , 2010, Medical physics.

[11]  I. Das,et al.  Small fields: nonequilibrium radiation dosimetry. , 2007, Medical physics.

[12]  H D Kubo,et al.  Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. , 1999, International journal of radiation oncology, biology, physics.

[13]  Ke Sheng,et al.  Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: plan quality, delivery efficiency and accuracy. , 2010, Medical physics.

[14]  Kelly J. Christian,et al.  Dosimetric effects near implanted vascular access ports: an examination of external photon beam dose calculations , 2009, Journal of applied clinical medical physics.

[15]  N. Suchowerska,et al.  Directional dependence in film dosimetry: radiographic and radiochromic film. , 2001, Physics in medicine and biology.

[16]  Tanya Kairn,et al.  The development of a Monte Carlo system to verify radiotherapy treatment dose calculations , 2009 .

[17]  T Kairn,et al.  Local heterogeneities in early batches of EBT2 film: a suggested solution , 2010, Physics in medicine and biology.

[18]  Martin J Butson,et al.  Measurement of high energy x-ray beam penumbra with Gafchromic™ EBT radiochromic film. , 2006, Medical physics.

[19]  P. Cavazzani,et al.  Fractionated stereotactic radiotherapy: a method to evaluate geometric and dosimetric uncertainties using radiochromic films. , 2009, Medical physics.

[20]  Daniel A Low,et al.  Gamma Dose Distribution Evaluation Tool , 2010 .

[21]  Tanya Kairn,et al.  Accurately simulating the production of radiotherapy portal images using non-zero beam angles , 2011, HiPC 2011.

[22]  Piotr Zygmanski,et al.  Angular dose dependency of MatriXX TM and its calibration , 2010, Journal of applied clinical medical physics.

[23]  J. López Torrecilla,et al.  Prostate planning treatment volume margin calculation based on the ExacTrac X-Ray 6D image-guided system: margins for various clinical implementations. , 2007, International journal of radiation oncology, biology, physics.

[24]  P. Jursinic,et al.  MapCHECK used for rotational IMRT measurements: step-and-shoot, TomoTherapy, RapidArc. , 2010, Medical physics.

[25]  André Wambersie,et al.  The International Commission on Radiation Units and Measurements , 2001, Journal of the ICRU.

[26]  M. Butson,et al.  Energy response of the new EBT2 radiochromic film to x-ray radiation , 2010 .

[27]  D. Rogers,et al.  Monte Carlo calculated absorbed-dose energy dependence of EBT and EBT2 film. , 2010, Medical physics.

[28]  P Francescon,et al.  Quality assurance of volumetric modulated arc therapy: evaluation and comparison of different dosimetric systems. , 2011, Medical physics.

[29]  Piotr Zygmanski,et al.  Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions. , 2010, Medical physics.

[30]  Peter Kneschaurek,et al.  A Planning Comparison of Dynamic IMRT for Different Collimator Leaf Thicknesses with Helical Tomotherapy and RapidArc for Prostate and Head and Neck Tumors , 2010, Strahlentherapie und Onkologie.

[31]  T. Mackie,et al.  A phantom model demonstration of tomotherapy dose painting delivery, including managed respiratory motion without motion management , 2010, Physics in medicine and biology.

[32]  W. Tomé,et al.  Endo-rectal balloon cavity dosimetry in a phantom: performance under IMRT and helical tomotherapy beams. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[33]  G. Ding,et al.  A study on beams passing through hip prosthesis for pelvic radiation treatment. , 2001, International journal of radiation oncology, biology, physics.