An encoded particle array tool for multiplex bioassays.

The detection of both gene function at the genomic scale and protein assays at a proteomic scale is developing into an essential tool in the discovery and development of new medicines. A wide variety of techniques have been used that allow the analyst to assess the information gathered from a SNP up to a fully developed immunoassay. Despite these advances, there remains an ongoing drive to keep the cost of research and development down to reduce the cost of bringing a new drug or diagnostic to market. The demand to carry out large-scale bioassay analysis using yet smaller reagent volume and at a very low cost per test is gaining much importance as seen in the growing need to perform multiplex bioassays. In this article, we describe an analytical system that is being developed to address such a need for multiplexing bioassays at a low, affordable cost providing a flexible alternative consumable to the current technologies. This novel system utilizes inexpensive fabricated polymeric material produced by standard MEMS technology, which allows the attachment, through a variety of coupling chemistries, of oligonucleotides, proteins, antibodies, and antigens. These can then be analyzed by simple scanning, with either a flow cytometer or a simple optical reader, providing a robust, sensitive microarray assay system.

[1]  E. Gabrielson,et al.  Combined use of oligonucleotide and tissue microarrays identifies cancer/testis antigens as biomarkers in lung carcinoma. , 2002, Cancer research.

[2]  J. V. Moran,et al.  Initial sequencing and analysis of the human genome. , 2001, Nature.

[3]  Tibor Chován,et al.  Microfabricated devices in biotechnology and biochemical processing. , 2002, Trends in biotechnology.

[4]  Sandra J. Rosenthal,et al.  Bar-coding biomolecules with fluorescent nanocrystals , 2001, Nature Biotechnology.

[5]  U. Prabhakar,et al.  Simultaneous quantification of proinflammatory cytokines in human plasma using the LabMAP assay. , 2002, Journal of immunological methods.

[6]  M. Weiner,et al.  Multiplexed single nucleotide polymorphism genotyping by oligonucleotide ligation and flow cytometry. , 2000, Cytometry.

[7]  Marco Seri,et al.  Analysis of clinically relevant single-nucleotide polymorphisms by use of microelectronic array technology. , 2002, Clinical chemistry.

[8]  D. Balding,et al.  HLA Sequence Polymorphism and the Origin of Humans , 2006 .

[9]  M. Buti,et al.  Quantitative detection of hepatitis B virus DNA in serum by a new rapid real‐time fluorescence PCR assay , 2001, Journal of viral hepatitis.

[10]  S. Nie,et al.  Quantum dot bioconjugates for ultrasensitive nonisotopic detection. , 1998, Science.

[11]  A. Berno,et al.  New developments in high‐throughput resequencing and variation detection using high density microarrays , 2002, Human mutation.

[12]  M Nees,et al.  Microarrays: spotlight on gene function and pharmacogenomics. , 2001, Current cancer drug targets.

[13]  Kevin Braeckmans,et al.  Encoding microcarriers: present and future technologies , 2002, Nature Reviews Drug Discovery.