Three-wavelength technique for the measurement of oxygen saturation in arterial blood and in venous blood.

Pulse oximetry is an optical technique for the assessment of oxygen saturation in arterial blood and is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and on two-wavelength photoplethysmographic (PPG) measurement of arterial blood volume increase during systole. The technique requires experimental calibration for the determination of the relationship between PPG-derived parameters and arterial oxygen saturation, and this calibration is a source of error in the method. We suggest a three-wavelength PPG technique for the measurement of arterial oxygen saturation that has no need for calibration if the three wavelengths are properly selected in the near-infrared region. The suggested technique can also be implemented for the assessment of venous oxygen saturation by measuring the decrease in transmission of light through a tissue after increasing its blood volume by venous occlusion. The oxygen saturation in venous blood is a parameter that is related to oxygen consumption in tissue and to tissue blood flow. The three-wavelength method has the potential to provide accurate oxygen saturation measurements in arterial and venous blood, but experimental validation of the theory is still required to confirm this claim.

[1]  D. Delpy,et al.  Quantification in tissue near–infrared spectroscopy , 1997 .

[2]  E. Reynolds,et al.  Introduction to a Discussion on Near-infrared spectroscopy and imaging of living systems. , 1997 .

[3]  P.D. Mannheimer,et al.  Wavelength selection for low-saturation pulse oximetry , 1997, IEEE Transactions on Biomedical Engineering.

[4]  M. Nitzan,et al.  The measurement of oxygen saturation in arterial and venous blood , 2008, IEEE Instrumentation & Measurement Magazine.

[5]  Oliver Wieben LIGHT ABSORBANCE IN PULSE OXIMETRY , 1997 .

[6]  Martin Wolf,et al.  Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications. , 2007, Journal of biomedical optics.

[7]  D T Delpy,et al.  In vivo measurements of the wavelength dependence of tissue-scattering coefficients between 760 and 900 nm measured with time-resolved spectroscopy. , 1997, Applied optics.

[8]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .

[9]  Frans F. Jo¨bsis-vanderVliet,et al.  Biochemical and physiological basis of medical near-infrared spectroscopy. , 1999, Journal of biomedical optics.

[10]  F F Jo Bsis-Vandervliet,et al.  Biochemical and physiological basis of medical near-infrared spectroscopy. , 1999, Journal of biomedical optics.

[11]  Thomas J Barstow,et al.  Effects of assuming constant optical scattering on measurements of muscle oxygenation by near-infrared spectroscopy during exercise. , 2007, Journal of applied physiology.

[12]  Y. Mendelson,et al.  Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography , 1988, IEEE Transactions on Biomedical Engineering.

[13]  B Chance,et al.  Quantification of ischemic muscle deoxygenation by near infrared time-resolved spectroscopy. , 2000, Journal of biomedical optics.

[14]  M. Nitzan,et al.  Measurement of oxygen saturation in venous blood by dynamic near infrared spectroscopy. , 2000, Journal of biomedical optics.

[15]  M. Nitzan,et al.  Fiber optic sensor for the measurement of respiratory chest circumference changes. , 1999, Journal of biomedical optics.

[16]  Y. Shimada,et al.  Spectrophotometric monitoring of arterial oxygen saturation in the fingertip , 2006, Medical and Biological Engineering and Computing.

[17]  P. Kyriacou Pulse oximetry in the oesophagus , 2006, Physiological measurement.

[18]  S. Arridge,et al.  Experimentally measured optical pathlengths for the adult head, calf and forearm and the head of the newborn infant as a function of inter optode spacing. , 1992, Advances in experimental medicine and biology.

[19]  D. Delpy,et al.  Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy. , 1995, Physics in medicine and biology.