The effect of floor heat source area on the induced airflow in a room

We examine the role of heat source geometry in determining rates of airflow and thermal stratification in natural displacement ventilation flows. We modify existing models to account for heat sources of finite (non-zero) area, such as formed by a sun patch warming the floor of a room. Our model allows for predictions of the steady stratification and ventilation flow rates that develop in a room due to a circular heat source at floor level. We compare our theoretical predictions with predictions for the limiting cases of a point source of heat (yielding a stratified interior), and a uniformly heated floor (yielding a mixed interior). Our theory shows a smooth transition between these two limits, which themselves result in extremes of ventilation, as the ratio of the heat source radius to the room height increases. Our model for the transition from displacement to mixing ventilation is compared to previous work and demonstrates that the transition can occur for smaller sources than previously thought, particularly for rooms with large floor area compared to ceiling height.

[1]  Paul Cooper,et al.  Multiple sources of buoyancy in a naturally ventilated enclosure , 1996 .

[2]  David A. Smeed,et al.  Emptying filling boxes: the fluid mechanics of natural ventilation , 1990, Journal of Fluid Mechanics.

[3]  Gary R. Hunt,et al.  Time-dependent flows in an emptying filling box , 2004, Journal of Fluid Mechanics.

[4]  Gary R. Hunt,et al.  Virtual origin correction for lazy turbulent plumes , 2001, Journal of Fluid Mechanics.

[5]  K. Terpager Andersen,et al.  Theoretical considerations on natural ventilation by thermal buoyancy , 1995 .

[6]  H. Fernando,et al.  Turbulent convection from isolated sources , 1999 .

[7]  T. Fannelop,et al.  An experimental study of starting plumes over area sources , 1999 .

[8]  Jason H. Middleton,et al.  Scale diagrams for forced plumes , 1973, Journal of Fluid Mechanics.

[9]  S. J. Barnett The dynamics of buoyant releases in confined spaces , 1992 .

[10]  J. Fontaine,et al.  An experimental study of the thermal plume developed above a finite cylindrical heat source to validate the point source model , 2007 .

[11]  Witold M. Lewandowski,et al.  The Effect of Plate Size on the Natural Convective Heat Transfer Intensity of Horizontal Surfaces , 2005 .

[12]  Paul Cooper,et al.  Natural ventilation of an enclosure containing two buoyancy sources , 1996, Journal of Fluid Mechanics.

[13]  Andrew W. Woods,et al.  On buoyancy-driven natural ventilation of a room with a heated floor , 2001, Journal of Fluid Mechanics.

[14]  Andrew W. Woods,et al.  The mixing in a room by a localized finite-mass-flux source of buoyancy , 2002, Journal of Fluid Mechanics.

[15]  D. M. Webber,et al.  On buoyant plumes rising from area sources in a calm environment , 2003, Journal of Fluid Mechanics.

[16]  G. Batchelor,et al.  Heat convection and buoyancy effects in fluids , 1954 .

[17]  M. Epstein,et al.  Vertical mixing above a steady circular source of buoyancy , 2001 .

[18]  Gary R. Hunt,et al.  Heat source modelling and natural ventilation efficiency , 2007 .

[19]  Geoffrey Ingram Taylor,et al.  Turbulent gravitational convection from maintained and instantaneous sources , 1956, Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences.

[20]  P. Linden,et al.  Interacting Turbulent Plumes in a Naturally Ventilated Enclosure , 2006 .

[21]  Gary S. Settles,et al.  Computational Study of the Wake and Contaminant Transport of a Walking Human , 2005 .

[22]  G. Hunt,et al.  An experimental study of large area source turbulent plumes , 2009 .