Monitoring of rabbit cornea response to dehydration stress by optical coherence tomography.

PURPOSE To evaluate the application of optical coherence tomography (OCT) for continuous noninvasive monitoring and quantification of the dynamics of corneal response after exposure of the cornea to dehydrating stress. METHODS The changes in central corneal thickness (CCT) and scattering properties of the cornea were monitored with OCT in rabbit cornea in vivo after topical application of a glycerin-based hypertonic agent (HA) or prolonged surface evaporation of the cornea. The observed changes in backscatter were correlated with the changes in corneal hydration. RESULTS An inverse relationship was found between the logarithm of the intensity of backscatter within the cornea and the degree of corneal hydration at which the intensity of the backscatter changed up to 20 times between the peak of the de- and rehydration phases. An analytical relationship is derived between the magnitude of the backscatter from the stroma and the extent of corneal hydration. Furthermore, depending on the concentration of the drug, a peak overshoot in corneal thickness in the range of 40% to 90% was detected during the rehydration process after topical application of the HA. At a 100% concentration of HA, the average dehydration rate was 74 microm/min, whereas the average rehydration rate was 12.4 microm/min. The same parameters for surface evaporation were 2.7 and 1.5 microm/min, respectively. CONCLUSIONS OCT may offer a unique capability to quantitatively monitor the dynamics of corneal response and to assess corneal function based on noninvasive detection of the changes in the optical properties and morphology of the cornea after topical application of dehydrating agents.

[1]  Massoud Motamedi,et al.  In-vivo OCT assessment of rabbit corneal hydration and dehydration , 2003, SPIE BiOS.

[2]  Massoud Motamedi,et al.  Precision of measurement of tissue optical properties with optical coherence tomography. , 2003, Applied optics.

[3]  Wolfgang Drexler,et al.  Short-term effect of dorzolamide hydrochloride on central corneal thickness in humans with cornea guttata. , 2003, Archives of ophthalmology.

[4]  T. Olsen,et al.  Light scattering from the human cornea. , 1982, Investigative ophthalmology & visual science.

[5]  D. Monti,et al.  Increased corneal hydration induced by potential ocular penetration enhancers: assessment by differential scanning calorimetry (DSC) and by desiccation. , 2002, International journal of pharmaceutics.

[6]  M. Luxenberg,et al.  Reduction of corneal edema with topical hypertonic agents. , 1971, American journal of ophthalmology.

[7]  M Motamedi,et al.  Noninvasive assessment of the hydration gradient across the cornea using confocal Raman spectroscopy. , 1998, Investigative ophthalmology & visual science.

[8]  W. M. Bourne,et al.  Human corneal endothelial tolerance to glycerol, dimethylsulfoxide, 1,2-propanediol, and 2,3-butanediol. , 1994, Cryobiology.

[9]  P. Madden The assessment of endothelial integrity by scanning electron microscopy and fluorescein diacetate staining following treatment with cryoprotective additives. , 1989, Current eye research.

[10]  D. Hodge,et al.  Corneal hydration control in diabetes mellitus. , 1995, Investigative Ophthalmology and Visual Science.

[11]  D. Maurice,et al.  The Cornea and Sclera , 1962 .

[12]  M. D. Moores,et al.  In vivo detection of experimentally induced cortical dysgenesis in the adult rat neocortex using optical coherence tomography , 1998, Journal of Neuroscience Methods.

[13]  S. Priglinger,et al.  Sterile Structural Imaging of Donor Cornea by Optical Coherence Tomography , 2002, Cornea.

[14]  D. Pham,et al.  Histopathological correlation of corneal diseases with optical coherence tomography , 2002, Graefe’s Archive for Clinical and Experimental Ophthalmology.

[15]  J. Goodman Some fundamental properties of speckle , 1976 .

[16]  H. Venema,et al.  In vivo human corneal hydration control dynamics: a new model. , 1999, Investigative ophthalmology & visual science.

[17]  W. Armitage,et al.  The potential of an equimolar combination of propane-1,2-diol and glycerol as a vitrification solution for corneas. , 1991, Cryobiology.

[18]  F. Bettelheim,et al.  Water gradients across bovine cornea. , 1988, Investigative ophthalmology & visual science.

[19]  R B Mandell,et al.  Corneal hydration control in Fuchs' dystrophy. , 1989, Investigative ophthalmology & visual science.

[20]  G. Grass,et al.  Mechanisms of corneal drug penetration. I: In vivo and in vitro kinetics. , 1988, Journal of pharmaceutical sciences.

[21]  Kim L. Boyer,et al.  Retinal thickness measurements from optical coherence tomography using a Markov boundary model , 2001, IEEE Transactions on Medical Imaging.

[22]  A. W. Siu,et al.  The effect of age on the edema response of the central and mid‐peripheral cornea , 1993, Acta ophthalmologica.

[23]  R. Boltz,et al.  Effect of humidity on the deswelling function of the human cornea. , 1991, Current eye research.

[24]  J. Schmitt,et al.  Speckle in optical coherence tomography. , 1999, Journal of biomedical optics.

[25]  J. McLaren,et al.  Effect of dorzolamide on corneal endothelial function in normal human eyes. , 1998, Investigative ophthalmology & visual science.

[26]  W. M. Bourne,et al.  Tolerance of human corneal endothelium to glycerol. , 1989, Cryobiology.

[27]  S. Klyce,et al.  NaCl osmotic perturbation can modulate hydration control in rabbit cornea. , 2003, Experimental eye research.

[28]  W. Armitage,et al.  Corneal tolerance of vitrifiable concentrations of glycerol. , 1992, Cryobiology.

[29]  K A Polse,et al.  In vivo assessment of mechanisms controlling corneal hydration. , 1985, Investigative ophthalmology & visual science.

[30]  M. Doughty,et al.  Human corneal thickness and its impact on intraocular pressure measures: a review and meta-analysis approach. , 2000, Survey of ophthalmology.

[31]  Luis Alonso,et al.  The relationship between central corneal thickness and Goldmann applanation tonometry , 2003, Clinical & experimental optometry.

[32]  Kirill V. Larin,et al.  Optimization of low-coherence interferometry for quantitative analysis of tissue optical properties , 2002, SPIE BiOS.

[33]  D. Maurice The structure and transparency of the cornea , 1957, The Journal of physiology.

[34]  F. A. La Rosa,et al.  Central corneal thickness of Caucasians and African Americans in glaucomatous and nonglaucomatous populations. , 2001, Archives of ophthalmology.

[35]  Y Miyake,et al.  Optical Coherence Tomography for the Noninvasive Evaluation of the Cornea , 2001, Cornea.

[36]  P. Herse Corneal hydration control in normal and alloxan-induced diabetic rabbits. , 1990, Investigative ophthalmology & visual science.

[37]  S. Gorti,et al.  Determination of corneal gel dynamics , 1999, European Biophysics Journal.

[38]  P. Eggli,et al.  Morphological and functional analysis of immortalized human corneal endothelial cells after transplantation. , 1999, Experimental eye research.

[39]  K P Chan,et al.  Coherent detection techniques in optical imaging of tissues. , 1997, Physics in medicine and biology.

[40]  J. Welzel Optical coherence tomography in dermatology: a review , 2001, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[41]  S. Mishima,et al.  The thickness-hydration relationship of the cornea. , 1966, Experimental eye research.

[42]  W S Kim,et al.  Corneal Hydration Affects Ablation During Laser In Situ Keratomileusis Surgery , 2001, Cornea.

[43]  J. Taylor An Introduction to Error Analysis , 1982 .

[44]  M. Reim,et al.  Glucose Concentration and Hydration of the Corneal Stroma , 1971 .

[45]  J. Parel,et al.  Effect of corneal hydration on Goldmann applanation tonometry and corneal topography. , 1993, Refractive & corneal surgery.

[46]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[47]  R. Flom,et al.  Age differences in corneal hydration control. , 1989, Investigative ophthalmology & visual science.