Micropolar pulsatile blood flow conveying nanoparticles in a stenotic tapered artery: NON-Newtonian pharmacodynamic simulation

Two-dimensional rheological laminar hemodynamics through a diseased tapered artery with a mild stenosis present is simulated theoretically and computationally. The effect of different metallic nanoparticles homogeneously suspended in the blood is considered, motivated by drug delivery (pharmacology) applications. The Eringen micropolar model has been discussed for hemorheological characteristics in the whole arterial region. The conservation equations for mass, linear momentum, angular momentum (micro-rotation), and energy and nanoparticle species are normalized by employing suitable non-dimensional variables. The transformed equations are solved numerically subject to physically appropriate boundary conditions using the finite element method with the variational formulation scheme available in the FreeFEM++ code. A good correlation is achieved between the FreeFEM++ computations and existing results. The effect of selected parameters (taper angle, Prandtl number, Womersley parameter, pulsatile constants, and volumetric concentration) on velocity, temperature, and micro-rotational (Eringen angular) velocity has been calculated for a stenosed arterial segment. Wall shear stress, volumetric flow rate, and hemodynamic impedance of blood flow are also computed. Colour contours and graphs are employed to visualize the simulated blood flow characteristics. It is observed that by increasing Prandtl number (Pr), the micro-rotational velocity decreases i.e., microelement (blood cell) spin is suppressed. Wall shear stress decreases with the increment in pulsatile parameters (B and e), whereas linear velocity increases with a decrement in these parameters. Furthermore, the velocity decreases in the tapered region with elevation in the Womersley parameter (α). The simulations are relevant to transport phenomena in pharmacology and nano-drug targeted delivery in hematology.

[1]  Chandan Paul,et al.  Effect of coil embolization on blood flow through a saccular cerebral aneurysm , 2015 .

[2]  K. Vafai,et al.  A Mathematical Study of Non-Newtonian Micropolar Fluid in Arterial Blood Flow Through Composite Stenosis , 2014 .

[3]  J. Panda,et al.  The present and future of nanotechnology in human health care. , 2007, Nanomedicine : nanotechnology, biology, and medicine.

[4]  Zafar Hayat Khan,et al.  Mathematical modelling of pressure-driven micropolar biological flow due to metachronal wave propulsion of beating cilia. , 2018, Mathematical biosciences.

[5]  O. Bég,et al.  PERISTALTIC FLOW AND HYDRODYNAMIC DISPERSION OF A REACTIVE MICROPOLAR FLUID-SIMULATION OF CHEMICAL EFFECTS IN THE DIGESTIVE PROCESS , 2017 .

[6]  R. Padma,et al.  Mathematical modeling of electro hydrodynamic non-Newtonian fluid flow through tapered arterial stenosis with periodic body acceleration and applied magnetic field , 2019, Appl. Math. Comput..

[7]  G. Batchelor,et al.  The stress system in a suspension of force-free particles , 1970, Journal of Fluid Mechanics.

[8]  Nehad Ali Shah,et al.  Hemodynamic Characteristics of Gold Nanoparticle Blood Flow Through a Tapered Stenosed Vessel with Variable Nanofluid Viscosity , 2019, BioNanoScience.

[9]  Dharmendra Tripathi,et al.  A study on peristaltic flow of nanofluids: Application in drug delivery systems , 2014 .

[10]  O. Bég,et al.  Numerical simulation of time-dependent non-Newtonian nano-pharmacodynamic transport phenomena in a tapered overlapping stenosed artery , 2018 .

[11]  A. Eringen,et al.  Microcontinuum Field Theories II Fluent Media , 1999 .

[12]  K. Naidu,et al.  Finite element analysis of nonlinear pulsatile suspension flow dynamics in blood vessels with aneurysm. , 1995, Computers in biology and medicine.

[13]  O. Bég,et al.  Finite element analysis of non-Newtonian magnetohemodynamic flow conveying nanoparticles through a stenosed coronary artery , 2019, Heat Transfer-Asian Research.

[14]  Timothy W. Secomb,et al.  ASME Centennial Historical Perspective Paper: Mechanics of Blood Flow , 1981 .

[15]  S. Majumdar,et al.  Drag on an axially symmetric body in the Stokes’ flow of micropolar fluid , 1976 .

[16]  H. Wayland RHEOLOGY AND MICROCIRCULATION. , 1965, Bibliotheca anatomica.

[17]  Sohail Nadeem,et al.  Influence of heat transfer on a peristaltic transport of Herschel–Bulkley fluid in a non-uniform inclined tube , 2009 .

[18]  D. Kassuha,et al.  Nanomedicine applied to cardiovascular diseases: latest developments , 2017, Therapeutic advances in cardiovascular disease.

[19]  V. Junyaprasert,et al.  Nanocrystals for enhancement of oral bioavailability of poorly water-soluble drugs , 2015 .

[20]  A. Haghighi,et al.  Mathematical modeling of blood flow through a stenosed artery under body acceleration , 2017 .

[21]  Mohammad Mehdi Rashidi,et al.  HOMOTOPY ANALYSIS OF TRANSIENT MAGNETO-BIO-FLUID DYNAMICS OF MICROPOLAR SQUEEZE FILM IN A POROUS MEDIUM: A MODEL FOR MAGNETO-BIO-RHEOLOGICAL LUBRICATION , 2012 .

[22]  Prashanta Kumar Mandal,et al.  Mathematical modelling of blood flow through an overlapping arterial stenosis , 1994 .

[23]  Rama Bhargava,et al.  Finite element study of nonlinear two-dimensional deoxygenated biomagnetic micropolar flow , 2010 .

[24]  Nasir Ali,et al.  Computational biomedical simulations of hybrid nanoparticles on unsteady blood hemodynamics in a stenotic artery , 2020, Math. Comput. Simul..

[25]  Nasir Ali,et al.  Numerical simulation of unsteady micropolar hemodynamics in a tapered catheterized artery with a combination of stenosis and aneurysm , 2015, Medical & Biological Engineering & Computing.

[26]  Giles R Cokelet,et al.  The rheology of human blood , 1963 .

[27]  R. Ponalagusamy,et al.  Computational model on pulsatile flow of blood through a tapered arterial stenosis with radially variable viscosity and magnetic field , 2017 .

[28]  T. Ariman On the analysis of blood flow. , 1971, Journal of biomechanics.

[29]  S. Nadeem,et al.  Consequences of blood mediated nano transportation as drug agent to attenuate the atherosclerotic lesions with permeability impacts , 2018, Journal of Molecular Liquids.

[30]  Prashanta Kumar Mandal,et al.  An unsteady analysis of non-Newtonian blood flow through tapered arteries with a stenosis , 2005 .

[31]  M. K. Chaube,et al.  Electroosmotic flow of biorheological micropolar fluids through microfluidic channels , 2018, Korea-Australia Rheology Journal.

[32]  M. Goodarzi,et al.  A 3-D numerical simulation of non-Newtonian blood flow through femoral artery bifurcation with a moderate arteriosclerosis: investigating Newtonian/non-Newtonian flow and its effects on elastic vessel walls , 2019, Heat and Mass Transfer.

[33]  R. Gambari,et al.  Recent advances in green nanoparticulate systems for drug delivery: efficient delivery and safety concern. , 2017, Nanomedicine.

[34]  Z. Abbas,et al.  Unsteady blood flow of non-Newtonian fluid through a rigid artery in the presence of multi-irregular stenoses , 2018, Journal of the Brazilian Society of Mechanical Sciences and Engineering.

[35]  E G Karvelas,et al.  Effect of micropolar fluid properties on the hydraulic permeability of fibrous biomaterials , 2020, Comput. Methods Programs Biomed..

[36]  Prashanta Kumar Mandal,et al.  Two-layered micropolar fluid flow through stenosed artery: Effect of peripheral layer thickness , 2009, Comput. Math. Appl..

[37]  C. Gans,et al.  Biomechanics: Motion, Flow, Stress, and Growth , 1990 .

[38]  R. Devanathan,et al.  Flow of micropolar fluid through a tube with stenosis , 1983, Medical and Biological Engineering and Computing.

[39]  Kh. S. Mekheimer,et al.  The micropolar fluid model for blood flow through a tapered artery with a stenosis , 2008 .

[40]  Sarifuddin,et al.  Numerical simulation of Casson fluid flow through differently shaped arterial stenoses , 2014 .

[41]  Kh. S. Mekheimer,et al.  Mathematical modelling of unsteady flow of a Sisko fluid through an anisotropically tapered elastic arteries with time-variant overlapping stenosis , 2012 .

[42]  Jiyuan Tu,et al.  Computational Hemodynamics – Theory, Modelling and Applications , 2015 .

[43]  A. Eringen,et al.  THEORY OF MICROPOLAR FLUIDS , 1966 .

[44]  D. Khanukaeva,et al.  Creeping flow of micropolar fluid through a swarm of cylindrical cells with porous layer (membrane) , 2019, Journal of Molecular Liquids.

[45]  Indu Mohan,et al.  Trends in Coronary Heart Disease Epidemiology in India. , 2016, Annals of global health.

[46]  M. J. Uddin,et al.  Unsteady forced bioconvection slip flow of a micropolar nanofluid from a stretching/shrinking sheet , 2016 .

[47]  Shewaferaw S Shibeshi,et al.  The Rheology of Blood Flow in a Branched Arterial System. , 2005, Applied rheology.

[48]  N. Samad Numerical solution of mass transfer to micropolar fluid flow past a stenosed artery , 2013 .

[49]  C K Kang,et al.  The effect of microstructure on the rheological properties of blood. , 1976, Bulletin of mathematical biology.

[50]  Tasawar Hayat,et al.  Power law fluid model for blood flow through a tapered artery with a stenosis , 2011, Appl. Math. Comput..

[51]  M. Anand,et al.  A SHEAR-THINNING VISCOELASTIC FLUID MODEL FOR DESCRIBING THE FLOW OF BLOOD , 2004 .

[52]  T. Nguyen,et al.  Modeling and analysis of biomagnetic blood Carreau fluid flow through a stenosis artery with magnetic heat transfer: A transient study , 2018, PloS one.

[53]  O. Anwar Bég,et al.  Computational fluid dynamic simulation of two-fluid non-Newtonian nanohemodynamics through a diseased artery with a stenosis and aneurysm , 2020, Computer methods in biomechanics and biomedical engineering.

[54]  O. Bég,et al.  Variable-viscosity thermal hemodynamic slip flow conveying nanoparticles through a permeable-walled composite stenosed artery , 2017 .

[55]  Y. Papaharilaou,et al.  Numerical modeling of non-Newtonian biomagnetic fluid flow , 2016 .

[56]  R. Ponalagusamy,et al.  A four-layered model for flow of non-Newtonian fluid in an artery with mild stenosis , 2019, Sādhanā.

[57]  J. Happel,et al.  Low Reynolds number hydrodynamics , 1965 .

[58]  R. Tiwari,et al.  HEAT TRANSFER AUGMENTATION IN A TWO-SIDED LID-DRIVEN DIFFERENTIALLY HEATED SQUARE CAVITY UTILIZING NANOFLUIDS , 2007 .