Carbon nanotube/polystyrene composite electrode for microchip electrophoretic determination of rutin and quercetin in Flos Sophorae Immaturus.

In this report, carbon nanotube/polystyrene (CNT/PS) composite electrodes have been fabricated as sensitive amperometric detectors of microchip capillary electrophoresis (CE) for the determination of rutin and quercetin in Flos Sophorae Immaturus. The composite electrode was fabricated on the basis of the in situ polymerization of a mixture of CNT and styrene in the microchannel of a piece of fused silica capillary under heat. The surface morphologies of the composite in the electrodes were observed by using a scanning electron microscope. The performance of this unique system has been demonstrated by separating and detecting rutin and quercetin. The new CNT-based CE detector offered significantly lower detection potentials, yielded substantially enhanced signal-to-noise characteristics, and exhibited resistance to surface fouling and hence enhanced stability. It demonstrated long-term stability and reproducibility with a relative standard deviation of less than 5% for the peak current (n=20) and should also find a wide range of applications in conventional CE, flowing injection analysis, and other microfluidic analysis systems.

[1]  Gang Chen,et al.  Carbon-nanotube/copper composite electrodes for capillary electrophoresis microchip detection of carbohydrates. , 2004, The Analyst.

[2]  Leif Nyholm,et al.  Electrochemical techniques for lab-on-a-chip applications. , 2005, The Analyst.

[3]  Ji Liang,et al.  DETERMINATION OF TRACE XANTHINE BY ANODIC STRIPPING VOLTAMMETRY WITH CARBON NANOTUBE MODIFIED GLASSY CARBON ELECTRODE , 2002 .

[4]  H. Kappus,et al.  Alkane formation during liver microsomal lipid peroxidation. , 1982, Biochemical pharmacology.

[5]  E. Cadahía,et al.  HPLC analysis of flavonoids and phenolic acids and aldehydes inEucalyptus spp. , 1995 .

[6]  C. Banks,et al.  Exploring the electrocatalytic sites of carbon nanotubes for NADH detection: an edge plane pyrolytic graphite electrode study. , 2005, The Analyst.

[7]  Qi Wang,et al.  Polymer/carbon nanotube composite emulsion prepared through ultrasonically assisted in situ emulsion polymerization , 2006 .

[8]  Susan M Lunte,et al.  Recent developments in amperometric detection for microchip capillary electrophoresis , 2002, Electrophoresis.

[9]  Hu-lin Li,et al.  SWNTs-polystyrene composites preparations and electrical properties research , 2006 .

[10]  Martin Pumera,et al.  Microchip Capillary Electrophoresis with a Single-Wall Carbon Nanotube/Gold Electrochemical Detector for Determination of Aminophenols and Neurotransmitters , 2006 .

[11]  David J. Fischer,et al.  Recent developments in electrochemical detection for microchip capillary electrophoresis , 2004, Electrophoresis.

[12]  Wei‐De Zhang,et al.  Anodic oxidation of hydrazine at carbon nanotube powder microelectrode and its detection. , 2002, Talanta.

[13]  Gang Chen,et al.  Determination of rutin and quercetin in plants by capillary electrophoresis with electrochemical detection. , 2000 .

[14]  S. Iijima Helical microtubules of graphitic carbon , 1991, Nature.

[15]  Gang Chen,et al.  Fabrication and performance of a three‐dimensionally adjustable device for the amperometric detection of microchip capillary electrophoresis , 2005, Electrophoresis.

[16]  Martindale : the extra pharmacopoeia , 1996 .

[17]  Gang Chen,et al.  Carbon nanotube/poly(methyl methacrylate) composite electrode for capillary electrophoretic measurement of honokiol and magnolol in Cortex Magnoliae Officinalis , 2006, Electrophoresis.

[18]  T. Parella,et al.  Anti-inflammatory and analgesic activity of Baccharis trimera: identification of its active constituents. , 1996, Planta medica.

[19]  P. Ajayan Nanotubes from Carbon. , 1999, Chemical reviews.

[20]  J. Kong,et al.  Magnetic loading of carbon nanotube/nano-Fe(3)O(4) composite for electrochemical sensing. , 2007, Talanta.

[21]  B. Meier,et al.  Qualitative and quantitative reversed-phase high-performance liquid chromatography of flavonoids in Crataegus leaves and flowers , 1994 .

[22]  Joseph Wang,et al.  Electrochemical detection for microscale analytical systems: a review. , 2002, Talanta.

[23]  Di Chen,et al.  Low temperature bonding of poly(methylmethacrylate) electrophoresis microchips by in situ polymerisation. , 2005, Journal of chromatography. A.

[24]  Gang Chen,et al.  A three-dimensionally adjustable amperometric detector for microchip electrophoretic measurement of nitroaromatic pollutants. , 2006, Talanta.

[25]  Shouzhuo Yao,et al.  Fabrication of polyaniline/carbon nanotube composite modified electrode and its electrocatalytic property to the reduction of nitrite , 2005 .

[26]  Wei-Hua Huang,et al.  Carbon fiber nanoelectrodes modified by single-walled carbon nanotubes. , 2003, Analytical chemistry.

[27]  Susan M Lunte,et al.  In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat. , 2002, Analytical chemistry.

[28]  R. Varma,et al.  Growth inhibitory effects of bioflavonoids and related compounds on human leukemic CEM-C1 and CEM-C7 cells. , 1992, Cancer Letters.

[29]  Gang Chen,et al.  Capillary electrophoresis microchip with a carbon nanotube-modified electrochemical detector. , 2004, Analytical chemistry.

[30]  B. Meier,et al.  High-performance liquid chromatographic determination of five widespread flavonoid aglycones. , 1990, Journal of chromatography.

[31]  Darwin R. Reyes,et al.  Micro total analysis systems. 2. Analytical standard operations and applications. , 2002, Analytical chemistry.

[32]  Darwin R. Reyes,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.

[33]  R. R. Moore,et al.  Basal plane pyrolytic graphite modified electrodes: comparison of carbon nanotubes and graphite powder as electrocatalysts. , 2004, Analytical chemistry.

[34]  W. D. de Heer,et al.  Carbon Nanotubes--the Route Toward Applications , 2002, Science.

[35]  Jun Liu,et al.  Carbon nanotube-modified electrodes for the simultaneous determination of dopamine and ascorbic acid. , 2002, The Analyst.

[36]  Gang Chen,et al.  Miniaturized capillary electrophoresis system with a carbon nanotube microelectrode for rapid separation and detection of thiols. , 2004, Talanta.

[37]  G. Rivas,et al.  Carbon nanotubes paste electrodes as new detectors for capillary electrophoresis , 2005 .

[38]  Gang Chen,et al.  Monitoring environmental pollutants by microchip capillary electrophoresis with electrochemical detection. , 2006, Talanta.

[39]  Mei Gao,et al.  Aligned Coaxial Nanowires of Carbon Nanotubes Sheathed with Conducting Polymers , 2000 .

[40]  W. Brittain,et al.  Conductivity and mechanical properties of well-dispersed single-wall carbon nanotube/polystyrene composite , 2006 .

[41]  Joseph Wang,et al.  Enzyme-dispersed carbon-nanotube electrodes: a needle microsensor for monitoring glucose. , 2003, The Analyst.