2-D full wave solution for the analysis and design of birdcage coils

A simple 2-D full wave model for the birdcage coil is described that includes the effects of shields, lossy layered media, and finite leg widths. This model has been implemented in Matlab, which provides a simple user interface. Using this model, various coil parameters such as signal-to-noise ratio (SNR), magnetic field homogeneity, magnetic field magnitude, etc. can be computed quickly. The efficiency of this model allows optimization of the coil geometry for particular applications. A method for finding the optimal coil radius in terms of SNR and homogeneity, given shield and sample radii, is presented. © 2003 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 18B: 15–23, 2003.

[1]  T. M. Fitzgerald,et al.  Generalized electrical analysis of low-pass and high-pass birdcage resonators. , 1991, Magnetic resonance imaging.

[2]  Jullie W Pan,et al.  High frequency volume coils for clinical NMR imaging and spectroscopy , 1994, Magnetic resonance in medicine.

[3]  P M Joseph,et al.  A technique for double resonant operation of birdcage imaging coils. , 1989, IEEE transactions on medical imaging.

[4]  M. Harpen,et al.  Equivalent circuit for birdcage resonators , 1993, Magnetic resonance in medicine.

[5]  R. Harrington Time-Harmonic Electromagnetic Fields , 1961 .

[6]  On the field inhomogeneity of a birdcage coil , 1994, Magnetic resonance in medicine.

[7]  J. Schenck,et al.  An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 T , 1985 .

[8]  Qing X. Yang,et al.  A Method for Evaluating the Magnetic Field Homogeneity of a Radiofrequency Coil by Its Field Histogram , 1994 .

[9]  T K Foo,et al.  An analytical model for the design of RF resonators for MR body imaging , 1991, Magnetic resonance in medicine.

[10]  Orhan Nalcioglu,et al.  An fem approach for the characterization of the RF field homogeneity at high field , 1997, Magnetic resonance in medicine.

[11]  RF coil optimization: evaluation of B1 field homogeneity using field histograms and finite element calculations. , 1994, Magnetic resonance imaging.

[12]  T. Ibrahim,et al.  B1 field homogeneity and SAR calculations for the birdcage coil , 2001 .

[13]  Jianming Jin,et al.  Numerical simulation of SAR and B1-field inhomogeneity of shielded RF coils loaded with the human head. , 1998, IEEE transactions on bio-medical engineering.

[14]  D. Hoult Sensitivity and Power Deposition in a High‐Field Imaging Experiment , 2000, Journal of magnetic resonance imaging : JMRI.