Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system.

A new method using a double-sensor difference based algorithm for analyzing human segment rotational angles in two directions for segmental orientation analysis in the three-dimensional (3D) space was presented. A wearable sensor system based only on triaxial accelerometers was developed to obtain the pitch and yaw angles of thigh segment with an accelerometer approximating translational acceleration of the hip joint and two accelerometers measuring the actual accelerations on the thigh. To evaluate the method, the system was first tested on a 2 degrees of freedom mechanical arm assembled out of rigid segments and encoders. Then, to estimate the human segmental orientation, the wearable sensor system was tested on the thighs of eight volunteer subjects, who walked in a straight forward line in the work space of an optical motion analysis system at three self-selected speeds: slow, normal and fast. In the experiment, the subject was assumed to walk in a straight forward way with very little trunk sway, skin artifacts and no significant internal/external rotation of the leg. The root mean square (RMS) errors of the thigh segment orientation measurement were between 2.4 degrees and 4.9 degrees during normal gait that had a 45 degrees flexion/extension range of motion. Measurement error was observed to increase with increasing walking speed probably because of the result of increased trunk sway, axial rotation and skin artifacts. The results show that, without integration and switching between different sensors, using only one kind of sensor, the wearable sensor system is suitable for ambulatory analysis of normal gait orientation of thigh and shank in two directions of the segment-fixed local coordinate system in 3D space. It can then be applied to assess spatio-temporal gait parameters and monitoring the gait function of patients in clinical settings.

[1]  N. Hagemeister,et al.  A reproducible method for studying three-dimensional knee kinematics. , 2005, Journal of biomechanics.

[2]  B M Nigg,et al.  A method for inverse dynamic analysis using accelerometry. , 1996, Journal of biomechanics.

[3]  Peter H. Veltink,et al.  Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing , 2007, IEEE Transactions on Biomedical Engineering.

[4]  Peter H. Veltink,et al.  Measuring orientation of human body segments using miniature gyroscopes and accelerometers , 2005, Medical and Biological Engineering and Computing.

[5]  Steven Morrison,et al.  Reliability of segmental accelerations measured using a new wireless gait analysis system. , 2006, Journal of biomechanics.

[6]  Roman Kamnik,et al.  An inertial and magnetic sensor based technique for joint angle measurement. , 2007, Journal of biomechanics.

[7]  J Y Goulermas,et al.  Predicting lower limb joint kinematics using wearable motion sensors. , 2008, Gait & posture.

[8]  K. Aminian,et al.  Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement. , 2004, Gait & posture.

[9]  Pascal Fua,et al.  Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors , 2006, IEEE Transactions on Biomedical Engineering.

[10]  Rachid Aissaoui,et al.  New Accelerometric Method to Discriminate Between Asymptomatic Subjects and Patients With Medial Knee Osteoarthritis During 3-D Gait , 2008, IEEE Transactions on Biomedical Engineering.

[11]  Peter H Veltink,et al.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. , 2002, Journal of biomechanics.

[12]  B. Andrews,et al.  Detecting absolute human knee angle and angular velocity using accelerometers and rate gyroscopes , 2001, Medical and Biological Engineering and Computing.

[13]  Kamiar Aminian,et al.  A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes , 2005, IEEE Transactions on Biomedical Engineering.

[14]  M. N. Nyan,et al.  Classification of gait patterns in the time-frequency domain. , 2006, Journal of biomechanics.

[15]  Hylton B Menz,et al.  Accelerometry: a technique for quantifying movement patterns during walking. , 2008, Gait & posture.

[16]  Alparslan Demirel,et al.  Recent developments and trends in biomedical sensors , 2005 .

[17]  W. Zijlstra,et al.  A body-fixed-sensor based analysis of compensatory trunk movements during unconstrained walking. , 2008, Gait & posture.

[18]  Claudia-Adina Dragos,et al.  Stable and optimal fuzzy control of a laboratory Antilock Braking System , 2010, 2010 IEEE/ASME International Conference on Advanced Intelligent Mechatronics.

[19]  K. Aminian,et al.  Ambulatory measurement of 3D knee joint angle. , 2008, Journal of biomechanics.

[20]  Tao Liu,et al.  Novel approach for lower limb segment orientation in gait analysis using triaxial accelerometers , 2008, 2008 IEEE/ASME International Conference on Advanced Intelligent Mechatronics.

[21]  Vladimir M. Zatsiorsky Kinematics of human motion , 1998 .