A borehole-to-surface electromagnetic survey

The results of a limited field trial confirm the usefulness of borehole‐to‐surface electromagnetic (EM) measurements for monitoring fluid extraction. A vertical EM profiling experiment was done at the University of California Richmond Field Station, where we simulated a brine spill plume by creating a saline water injection zone at the depth of 30 m. The data acquisition mode was analogous to the reverse vertical seismic profiling (VSP) configuration used for seismic measurements in that the EM transmitter traversed the PVC-cased borehole used for fluid injection and extraction while the receivers were deployed on the surface. The EM measurements were made at 9.6 kHz with an accuracy of 1% in signal amplitude and 1° in signal phase. Observations were taken at 5-m intervals along two intersecting profiles that were centered on the injection well and extended for 60 m on either side of it. The presence of the injected salt water, at the expected 30 m depth, was indicated clearly by differences between the p...