Characterization of a novel impedance cytometer design and its integration with lateral focusing by dielectrophoresis.

This paper reports a novel impedance cytometer design, easily integrable with dielectrophoretic focusing using a simple fabrication process with a single metal layer. Patterning of electrodes recessed in lateral channels - so-called "liquid electrodes" - allows the use of large electrodes while keeping a good spatial resolution. This larger area allows measurements at low frequencies, down to 1 kHz. It also decreases the current density, leading to electrodes more robust against electrochemical degradation. The relative change in impedance is simulated and compared to values reported in the literature for traditional designs, showing a smaller sensitivity for the proposed design due to the larger measurement volume. The device is evaluated with specific target applications, such as viability measurement and high-speed cell counting. Numerical simulations indicate that the proposed design reduces the dependence of the measurement on the vertical position of the particle compared to conventional designs, with a variation of only 5%, but is still dependent on its lateral position. This dependence is studied using focusing by dielectrophoresis (DEP) at different lateral positions across the microchannel, showing a larger sensitivity when the particles are close to the measurement electrodes, as confirmed by the numerical simulations. The integration of lateral dielectrophoresis to focus particles in the middle of the channel reduces the variation of the measurements to very small values, with a coefficient of variation of 5.6%, and allows precise particle sizing. Such a design can be very powerful to simplify the fabrication process of impedance cytometers and enables the production of cost-effective, possibly disposable devices.

[1]  Christian H. Reccius,et al.  Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry. , 2009, Lab on a chip.

[2]  P. Renaud,et al.  Characterization and optimization of liquid electrodes for lateral dielectrophoresis. , 2007, Lab on a chip.

[3]  Hywel Morgan,et al.  Single-cell microfluidic impedance cytometry: a review , 2010 .

[4]  Arkadiusz Pierzchalski,et al.  Microfluidic impedance‐based flow cytometry , 2010, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[5]  Philippe Renaud,et al.  A simple pneumatic setup for driving microfluidics. , 2007, Lab on a chip.

[6]  Andreas Hierlemann,et al.  Impedance characterization and modeling of electrodes for biomedical applications , 2005, IEEE Transactions on Biomedical Engineering.

[7]  Richard D. Rabbitt,et al.  Electric impedance spectroscopy using microchannels with integrated metal electrodes , 1999 .

[8]  Guillaume Mernier,et al.  Cell viability assessment by flow cytometry using yeast as cell model , 2011 .

[9]  P. Gascoyne,et al.  Particle separation by dielectrophoresis , 2002, Electrophoresis.

[10]  Urban Seger,et al.  Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations. , 2004, Lab on a chip.

[11]  P. Renaud,et al.  Focusing and Continuous Separation of Cells in a Microfluidic Device using Lateral Dielectrophoresis , 2007, TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference.

[12]  H Morgan,et al.  Analytical electric field and sensitivity analysis for two microfluidic impedance cytometer designs. , 2007, IET nanobiotechnology.

[13]  Guillaume Mernier,et al.  Multiple-frequency Impedance Measurements in Continuous Flow for the Evaluation of Electrical Lysis of Yeast Cells , 2010 .

[14]  Guillaume Mernier,et al.  Multiple-frequency impedance measurements in continuous flow for automated evaluation of yeast cell lysis , 2012 .

[15]  R. Tompkins,et al.  Continuous inertial focusing, ordering, and separation of particles in microchannels , 2007, Proceedings of the National Academy of Sciences.

[16]  Lisa C Shriver-Lake,et al.  Effect of diffusion on impedance measurements in a hydrodynamic flow focusing sensor. , 2010, Lab on a chip.

[17]  J.A. Schwartz,et al.  A three-dimensional dielectrophoretic particle focusing channel for microcytometry applications , 2005, Journal of Microelectromechanical Systems.

[18]  Guillaume Mernier,et al.  Label-free Sorting and Counting of Yeast Cells for Viability Studies , 2009 .

[19]  Thomas Braschler,et al.  Label-free detection of Babesia bovis infected red blood cells using impedance spectroscopy on a microfabricated flow cytometer. , 2007, Acta tropica.

[20]  Thomas Braschler,et al.  Continuous-flow electrical lysis device with integrated control by dielectrophoretic cell sorting. , 2010, Lab on a chip.

[21]  Jongin Hong,et al.  AC frequency characteristics of coplanar impedance sensors as design parameters. , 2005, Lab on a chip.

[22]  S. Gawad,et al.  Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. , 2001, Lab on a chip.

[23]  Hywel Morgan,et al.  Positional dependence of particles in microfludic impedance cytometry. , 2011, Lab on a chip.