State-of-the-Art Mobile Radiation Detection Systems for Different Scenarios

In the last decade, the development of more compact and lightweight radiation detection systems led to their application in handheld and small unmanned systems, particularly air-based platforms. Examples of improvements are: the use of silicon photomultiplier-based scintillators, new scintillating crystals, compact dual-mode detectors (gamma/neutron), data fusion, mobile sensor networks, cooperative detection and search. Gamma cameras and dual-particle cameras are increasingly being used for source location. This study reviews and discusses the research advancements in the field of gamma-ray and neutron measurements using mobile radiation detection systems since the Fukushima nuclear accident. Four scenarios are considered: radiological and nuclear accidents and emergencies; illicit traffic of special nuclear materials and radioactive materials; nuclear, accelerator, targets, and irradiation facilities; and naturally occurring radioactive materials monitoring-related activities. The work presented in this paper aims to: compile and review information on the radiation detection systems, contextual sensors and platforms used for each scenario; assess their advantages and limitations, looking prospectively to new research and challenges in the field; and support the decision making of national radioprotection agencies and response teams in respect to adequate detection system for each scenario. For that, an extensive literature review was conducted.

[1]  Kuniaki Kawabata,et al.  Remote radiation imaging system using a compact gamma-ray imager mounted on a multicopter drone , 2018 .

[2]  Ludek Zalud,et al.  Cooperation between an unmanned aerial vehicle and an unmanned ground vehicle in highly accurate localization of gamma radiation hotspots , 2018 .

[3]  Yukihisa Sanada,et al.  Distribution of the 134Cs/137Cs ratio around the Fukushima Daiichi nuclear power plant using an unmanned helicopter radiation monitoring system , 2015 .

[4]  T. Torii,et al.  Remote detection of radioactive hotspot using a Compton camera mounted on a moving multi-copter drone above a contaminated area in Fukushima , 2020 .

[5]  Anirban Mazumdar,et al.  A compact, maneuverable, underwater robot for direct inspection of nuclear power piping systems , 2012, 2012 IEEE International Conference on Robotics and Automation.

[6]  Kirill N. Shokhirev,et al.  Man-portable radiation detector based on advanced source detection, identification, and localization algorithms , 2015, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[7]  J. Ota,et al.  Radioactive source recognition with moving Compton camera imaging robot using Geant4 , 2020 .

[8]  Weng-Keen Wong,et al.  Status of research and development of learning-based approaches in nuclear science and engineering: A review , 2020 .

[9]  D. Cheneler,et al.  Material optimization in dual particle detectors by comparing advanced scintillating materials using two Monte Carlo codes , 2017 .

[10]  M. E. Medhat,et al.  Artificial intelligence methods applied for quantitative analysis of natural radioactive sources , 2012 .

[11]  Roland Siegwart,et al.  The current state and future outlook of rescue robotics , 2019, J. Field Robotics.

[12]  Pedro Teles,et al.  Performance Analysis of Geiger–Müller and Cadmium Zinc Telluride Sensors Envisaging Airborne Radiological Monitoring in NORM Sites , 2020, Sensors.

[13]  Edward R. Siciliano,et al.  Neutron detection alternatives to 3He for national security applications , 2010 .

[14]  K. Joo,et al.  Performance characteristics of a silicon photomultiplier based compact radiation detector for Homeland Security applications , 2015 .

[15]  Hsien-I Lin,et al.  Searching a radiological source by a mobile robot , 2015, 2015 International Conference on Fuzzy Theory and Its Applications (iFUZZY).

[16]  Juhani Lahtinen Emergency Monitoring Strategy and Radiation Measurements Working Document of the NKS Project Emergency Management and Radiation Monitoring in Nuclear and Radiological Accidents (EMARAD) , 2006 .

[17]  Yuki Sato,et al.  Radiation imaging using a compact Compton camera mounted on a crawler robot inside reactor buildings of Fukushima Daiichi Nuclear Power Station , 2019, Journal of Nuclear Science and Technology.

[18]  Rodrigo Ventura,et al.  Remote inspection with multi-copters, radiological sensors and SLAM techniques , 2018 .

[19]  Lubomír Gryc,et al.  Mapping of radiation anomalies using UAV mini-airborne gamma-ray spectrometry. , 2018, Journal of environmental radioactivity.

[20]  W. Jatmiko,et al.  Swarm quadrotor robots for telecommunication network coverage area expansion in disaster area , 2012, 2012 Proceedings of SICE Annual Conference (SICE).

[21]  David K. Miko,et al.  Evaluation of unmanned aerial vehicles for radiation detection , 2015 .

[22]  Nerine J. Cherepy,et al.  Bismuth-loaded plastic scintillators for gamma-ray spectroscopy , 2012 .

[23]  H.W. Kraner,et al.  Radiation detection and measurement , 1981, Proceedings of the IEEE.

[24]  Robin R. Murphy,et al.  Disaster Robotics , 2014, Springer Handbook of Robotics, 2nd Ed..

[25]  Kenji Fukuoka,et al.  A mobile cloud-based radiation monitoring system for citizens , 2015, 2015 IEEE Region 10 Humanitarian Technology Conference (R10-HTC).

[26]  Hideaki Yamamoto,et al.  Measurement of ambient dose equivalent rates by walk survey around Fukushima Dai-ichi Nuclear Power Plant using KURAMA-II until 2016. , 2018, Journal of environmental radioactivity.

[27]  Eijiro Takeuchi,et al.  Robotic control vehicle for measuring radiation in Fukushima Daiichi Nuclear Power Plant , 2011, 2011 IEEE International Symposium on Safety, Security, and Rescue Robotics.

[28]  Yufeng Xiao,et al.  Autonomous Search of Radioactive Sources through Mobile Robots , 2020, Sensors.

[29]  Yukihisa Sanada,et al.  Temporal variation of dose rate distribution around the Fukushima Daiichi nuclear power station using unmanned helicopter. , 2016, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[30]  Kelum A. A. Gamage,et al.  Coded-aperture imaging systems: Past, present and future development - A review , 2016 .

[31]  P. Peerani,et al.  Scintilla: A new international platform for the development, evaluation and benchmarking of technologies to detect radioactive and nuclear material , 2013, 2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (ANIMMA).

[32]  Wusheng Chou,et al.  Implementation of remotely operated vehicle for direct inspection of reactor pressure vessel and other water-filled infrastructure , 2016 .

[33]  R S O'Brien,et al.  Technologically enhanced naturally occurring radioactive material (NORM): pathway analysis and radiological impact. , 1998, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[34]  David Cheneler,et al.  Passive Gamma-Ray and Neutron Imaging Systems for National Security and Nuclear Non-Proliferation in Controlled and Uncontrolled Detection Areas: Review of Past and Current Status , 2019, Sensors.

[35]  Yukihisa Sanada,et al.  Aerial radiation monitoring around the Fukushima Dai-ichi Nuclear Power Plant using an unmanned helicopter. , 2015, Journal of environmental radioactivity.

[36]  J. Röning,et al.  Impact of Novel Technologies on Nuclear Security and Emergency Preparedness , 2019 .

[37]  S. Kurosawa,et al.  Field test around Fukushima Daiichi nuclear power plant site using improved Ce:Gd3(Al,Ga)5O12 scintillator Compton camera mounted on an unmanned helicopter , 2016 .

[38]  D. Cheneler,et al.  Design and Optimisation of a Three Layers Thermal Neutron, Fast Neutron and Gamma-Ray Imaging System , 2020, EPJ Web of Conferences.

[39]  Ikechukwu K. Ukaegbu,et al.  Ground Penetrating Radar as a Contextual Sensor for Multi-Sensor Radiological Characterisation , 2017, Sensors.

[40]  Woosoon Yim,et al.  Integration of CZT and CLYC radiation detectors into robotic platforms using ROS , 2019, 25TH INTERNATIONAL CONFERENCE ON THE APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY.

[41]  Automation und Messtechnik GmbH , 2004 .

[43]  Byoungil Jeon,et al.  Reconstruction of Compton Edges in Plastic Gamma Spectra Using Deep Autoencoder , 2020, Sensors.

[44]  A. Tremsin,et al.  Unique capabilities and applications of Microchannel Plate (MCP) detectors with Medipix/Timepix readout , 2020 .

[45]  H. Yamana,et al.  Development of a car-borne γ-ray survey system, KURAMA , 2013 .

[46]  S. Tsuda,et al.  Characteristics and verification of a car-borne survey system for dose rates in air: KURAMA-II. , 2015, Journal of environmental radioactivity.

[47]  Francesco Mondada,et al.  Autonomous Exploration for Radioactive Hotspots Localization Taking Account of Sensor Limitations , 2019, Sensors.

[48]  R. Thiruvengadathan,et al.  Advances in gamma radiation detection systems for emergency radiation monitoring , 2020, Nuclear Engineering and Technology.

[49]  A. Curioni,et al.  B-RAD: a radiation survey meter for operation in intense magnetic fields , 2019, Journal of Instrumentation.

[50]  Martin Saska,et al.  Timepix Radiation Detector for Autonomous Radiation Localization and Mapping by Micro Unmanned Vehicles , 2019, 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[51]  Rodrigo Ventura,et al.  Application of unmanned aerial vehicles for radiological inspection , 2017 .

[52]  T. Scott,et al.  Lightweight aerial vehicles for monitoring, assessment and mapping of radiation anomalies. , 2014, Journal of environmental radioactivity.

[53]  Makoto Arimoto,et al.  First demonstration of aerial gamma-ray imaging using drone for prompt radiation survey in Fukushima , 2017 .

[54]  R.T. Kouzes,et al.  Naturally occurring radioactive materials and medical isotopes at border crossings , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[55]  D. Sanderson,et al.  Demonstration of lightweight gamma spectrometry systems in urban environments. , 2013, Journal of environmental radioactivity.

[56]  Alberto Vale,et al.  Design Optimization of a Ducted-Drone to Perform Inspection Operations , 2019, ROBOT.

[57]  T. Mazor,et al.  SENTIRAD—An innovative personal radiation detector based on a scintillation detector and a silicon photomultiplier , 2011 .

[58]  Yangquan Chen,et al.  Multiple UAV Formations for Cooperative Source Seeking and Contour Mapping of a Radiative Signal Field , 2014, J. Intell. Robotic Syst..

[59]  John S. Fardoulis,et al.  The use of unmanned aerial systems for the mapping of legacy uranium mines. , 2015, Journal of environmental radioactivity.

[60]  Yi Liu,et al.  A New Disaster Information Sensing Mode: Using Multi-Robot System with Air Dispersal Mode , 2018, Sensors.

[61]  Robin R. Murphy,et al.  Autonomous Capabilities for Small Unmanned Aerial Systems Conducting Radiological Response: Findings from a High‐fidelity Discovery Experiment , 2014, J. Field Robotics.

[62]  D. Chambers,et al.  Uranium Mining and Norm in North America—Some Perspectives on Occupational Radiation Exposure , 2017, Health physics.

[63]  Atsushi Yamashita,et al.  3D radiation imaging using mobile robot equipped with radiation detector , 2017, 2017 IEEE/SICE International Symposium on System Integration (SII).

[64]  M. Brandauer,et al.  Decommissioning of Nuclear Facilities , 2019 .

[65]  Steve Fetter,et al.  Detecting nuclear warheads , 1990 .

[66]  Alexander Barzilov,et al.  Dual-Mode Radiation Sensor for UAS Platforms , 2019 .

[67]  Carina Cai,et al.  Designing a radiation sensing UAV system , 2016, 2016 IEEE Systems and Information Engineering Design Symposium (SIEDS).

[68]  K. Gamage,et al.  Pulse shape discrimination characteristics of stilbene crystal, pure and 6Li loaded plastic scintillators for a high resolution coded-aperture neutron imager , 2017 .

[69]  Yufeng Xiao,et al.  Integrating the radiation source position into a grid map of the environment using a mobile robot , 2020 .

[70]  Peter G. Martin,et al.  3D unmanned aerial vehicle radiation mapping for assessing contaminant distribution and mobility , 2016, Int. J. Appl. Earth Obs. Geoinformation.

[71]  T Berger,et al.  The German Aerospace Center M-42 radiation detector-A new development for applications in mixed radiation fields. , 2019, The Review of scientific instruments.

[72]  Avideh Zakhor,et al.  RadMAP: The Radiological Multi-sensor Analysis Platform , 2016 .

[73]  Andrew Haefner,et al.  Scene data fusion: Real-time standoff volumetric gamma-ray imaging , 2015 .

[74]  Vladimír Nečas,et al.  Unmanned Radiation Monitoring System , 2020 .

[75]  K. Shadan,et al.  Available online: , 2012 .

[76]  Jean Chagas Vaz,et al.  Study of radiation effects in electronics of a hexapod robotic platform , 2019 .

[77]  Yoeri Brouwer,et al.  Radioactive Hot-spot Detection Using Unmanned Aerial Vehicle Surveillance , 2020, EPJ Web of Conferences.

[78]  K. Boudergui,et al.  Development of a drone equipped with optimized sensors for nuclear and radiological risk characterization , 2011, 2011 2nd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications.

[79]  P. Becla,et al.  Novel Electrodes and Engineered Interfaces for Halide-Semiconductor Radiation Detectors , 2019, Scientific Reports.

[80]  D. Cheneler,et al.  A fast and portable imager for neutron and gamma emitting radionuclides , 2020 .

[81]  Nahrul Khair,et al.  Development of Autonomous Radiation Mapping Robot , 2017 .

[82]  B. de Celis,et al.  Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis. , 2008, Journal of environmental radioactivity.

[83]  D. Richards,et al.  High-resolution radiation mapping to investigate FDNPP derived contaminant migration. , 2016, Journal of environmental radioactivity.

[84]  Barry Lennox,et al.  A review of ground-based robotic systems for the characterization of nuclear environments , 2019, Progress in Nuclear Energy.

[85]  W. D. Smith,et al.  SORIS—A standoff radiation imaging system , 2011 .

[86]  P. Peerani,et al.  Special nuclear material detection with a mobile multi-detector system , 2012 .

[87]  A. Fauler,et al.  Evaluation of various Coplanar Grid (Cd,Zn)Te detector concepts for the application in gamma radiation surveillance and environmental monitoring detection systems , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[88]  P. Falciglia,et al.  Reclamation and management of polluted soils: options and case studies , 2018, Journal of Soils and Sediments.

[89]  Qiyuan Fu,et al.  Robotic modelling of snake traversing large, smooth obstacles reveals stability benefits of body compliance , 2020, Royal Society Open Science.

[90]  A. Baeza,et al.  Design and Implementation of a Mobile Radiological Emergency Unit Integrated in a Radiation Monitoring Network , 2013, IEEE Transactions on Nuclear Science.

[91]  Y. Yamashiki,et al.  Radiological comparison of a FDNPP waste storage site during and after construction. , 2018, Environmental pollution.

[92]  R. Ballabriga,et al.  submitter : Asic developments for radiation imaging applications: The medipix and timepix family , 2018 .

[93]  Hsien-I Lin,et al.  Search strategy of a mobile robot for radiation sources in an unknown environment , 2014, 2014 International Conference on Advanced Robotics and Intelligent Systems (ARIS).

[94]  Peter G Martin,et al.  Evaluation of Scintillator Detection Materials for Application within Airborne Environmental Radiation Monitoring , 2019, Sensors.

[95]  Nak Young Chong,et al.  Fast radiation mapping and multiple source localization using topographic contour map and incremental density estimation , 2016, 2016 IEEE International Conference on Robotics and Automation (ICRA).

[96]  Claudio Rossi,et al.  Design, Modeling and Control of a Spherical Autonomous Underwater Vehicle for Mine Exploration , 2018, 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[97]  Jie Ma,et al.  Design, simulation and manufacturing of a tracked robot for nuclear accidents , 2014, 2014 IEEE International Conference on Robotics and Biomimetics (ROBIO 2014).

[98]  M. Saleh,et al.  Radiological mapping of Kelantan, Malaysia, using terrestrial radiation dose rate , 2016, Isotopes in environmental and health studies.

[99]  Yangquan Chen,et al.  Low-cost Multi-UAV Technologies for Contour Mapping of Nuclear Radiation Field , 2013, J. Intell. Robotic Syst..

[100]  James Scanlan,et al.  Extreme Environments Robotics: Robotics for Emergency Response, Disaster Relief and Resilience , 2017 .

[101]  William S. Charlton,et al.  A strategic analysis of stationary radiation portal monitors and mobile detection systems in border monitoring , 2020 .

[102]  K. Ziock,et al.  A Dual-Sided Coded-Aperture Radiation Detection System , Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment , 2011 .

[103]  Norbert Zajzon,et al.  UNEXMIN: developing an autonomous underwater explorer for flooded mines , 2017 .

[104]  Jifu Zhao,et al.  Detection and parameter estimation of radioactive sources with mobile sensor networks , 2019 .

[105]  H. Seywerd,et al.  Silicon Photomultiplier-Based Compton Telescope for Safety and Security (SCoTSS) , 2013, IEEE Transactions on Nuclear Science.

[106]  Edward R. Siciliano,et al.  The use of energy windowing to discriminate SNM from NORM in radiation portal monitors , 2006 .

[107]  Frank E. Schneider,et al.  Possible scenarios for radiation measurements and sampling using unmanned systems: ERNCIP thematic group Radiological and nuclear threats to critical infrastructure - Task 3 deliverable 2 , 2015 .

[108]  E. Cisbani,et al.  SNIFFER: An aerial platform for the plume phase of a nuclear emergency , 2012 .

[109]  Daisei Konno,et al.  Simulation and validation of the Mobile Urban Radiation Search (MURS) gamma-ray detector response , 2020 .

[110]  Zhong He,et al.  The Polaris-H imaging spectrometer , 2015 .

[111]  Chang Hoi Kim,et al.  Application of robotics for the nuclear power plants in Korea , 2010, 2010 1st International Conference on Applied Robotics for the Power Industry.

[112]  Woosoon Yim,et al.  Low-altitude contour mapping of radiation fields using UAS swarm , 2019, Intell. Serv. Robotics.

[113]  M. Viola,et al.  Decommissioning of the Tokamak Fusion Test Reactor , 2003, 20th IEEE/NPSS Symposium onFusion Engineering, 2003..

[114]  Rong Chen,et al.  A dynamic fusion system for fast nuclear source detection and localization with mobile sensor networks , 2018 .

[115]  J. Saegusa,et al.  Using two detectors concurrently to monitor ambient dose equivalent rates in vehicle surveys of radiocesium contaminated land. , 2017, Journal of environmental radioactivity.

[116]  B. Phlips,et al.  Standoff detection of thermal and fast neutrons , 2015, 2015 IEEE International Symposium on Technologies for Homeland Security (HST).

[117]  Nak Young Chong,et al.  UAV-based multiple source localization and contour mapping of radiation fields , 2016, Robotics Auton. Syst..

[118]  Woosoon Yim,et al.  Plug-and-play radiation sensor components for unmanned aerial system platform , 2018, Journal of Radioanalytical and Nuclear Chemistry.

[119]  Yi Yao,et al.  Computer vision aided target linked radiation imaging , 2012, 2012 IEEE Conference on Computer Vision and Pattern Recognition.

[120]  Cheng-Yuan Chang,et al.  Sensing pipes of a nuclear power mechanism using low-cost snake robot , 2018 .

[121]  Atsushi Harayama,et al.  A portable Si/CdTe Compton camera and its applications to the visualization of radioactive substances , 2015 .

[122]  M. Oikawa,et al.  Radioactive contamination mapping of northeastern and eastern Japan by a car-borne survey system, Radi-Probe. , 2015, Journal of environmental radioactivity.

[123]  B. Seitz,et al.  Energy Resolution and Temperature Dependence of Ce:GAGG Coupled to Silicon Photomultipliers , 2016 .

[124]  European Reference Network for Critical Infrastructure Protection: - Novel Detection Technologies for Nuclear Security , 2018 .

[125]  M. Moszynski,et al.  Commissioning and Field Tests of a Van-Mounted System for the Detection of Radioactive Sources and Special Nuclear Material , 2016, IEEE Transactions on Nuclear Science.

[126]  S. Kuehn The REWARD project: Real Time Wide Area Radiation Surveillance with semiconductor detectors , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[127]  Yang Ishigaki,et al.  Development of Mobile Radiation Monitoring System Utilizing Smartphone and Its Field Tests in Fukushima , 2013, IEEE Sensors Journal.

[128]  G. Nebbia,et al.  A compact neutron–gamma spectrometer , 2013 .

[129]  Angular resolution study of a combined gamma-neutron coded aperture imager for standoff detection , 2013 .

[130]  Kazuya Yoshida,et al.  Emergency response to the nuclear accident at the Fukushima Daiichi Nuclear Power Plants using mobile rescue robots , 2013, J. Field Robotics.

[131]  M. Moszynski,et al.  Characterization of some modern scintillators recommended for use on large fusion facilities in γ-ray spectroscopy and tomographic measurements of γ-emission profiles , 2017 .

[132]  Alberto Jardón Huete,et al.  Underwater Robot Navigation for Maintenance and Inspection of Flooded Mine Shafts , 2018, 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[133]  Alexander Barzilov,et al.  Remote sensing of neutron and gamma radiation using aerial unmanned autonomous system , 2015, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC).

[134]  John S. Fardoulis,et al.  Low altitude unmanned aerial vehicle for characterising remediation effectiveness following the FDNPP accident. , 2016, Journal of environmental radioactivity.

[135]  C. Rovira,et al.  Set up of a gamma spectrometry mobile unit equipped with LaBr3(Ce) detectors for radioactivity monitoring , 2020 .

[136]  H.G. Tanner,et al.  Optimized Strategies for Smart Nuclear Search , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[137]  Rohan Bennett,et al.  Review of the Current State of UAV Regulations , 2017, Remote. Sens..

[138]  T. Scott,et al.  Airborne radiation mapping: overview and application of current and future aerial systems , 2016 .

[139]  Matthew Marino,et al.  Ten questions concerning the use of drones in urban environments , 2020 .

[140]  Jifu Zhao,et al.  Identifying anomalous nuclear radioactive sources using Poisson kriging and mobile sensor networks , 2019, PloS one.

[141]  S. Kuehn,et al.  Study of gamma detection capabilities of the REWARD mobile spectroscopic system , 2017 .

[142]  Haotong Wei,et al.  Halide lead perovskites for ionizing radiation detection , 2019, Nature Communications.

[143]  T. Torii,et al.  Construction of virtual reality system for radiation working environment reproduced by gamma-ray imagers combined with SLAM technologies , 2020 .

[144]  B. L. Gros,et al.  End-user experience with the SCoTSS Compton imager and directional survey spectrometer , 2020, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[145]  Yi Zhu,et al.  Use of Multi-Rotor Unmanned Aerial Vehicles for Radioactive Source Search , 2018, Remote. Sens..

[146]  Hye Min Park,et al.  Development and Performance Characteristics of Personal Gamma Spectrometer for Radiation Monitoring Applications , 2016, Sensors.

[147]  T. Scott,et al.  Validation of a novel radiation mapping platform for the reduction of operator-induced shielding effects , 2018, Journal of radiological protection : official journal of the Society for Radiological Protection.

[148]  Jason N. Gross,et al.  UGV-to-UAV cooperative ranging for robust navigation in GNSS-challenged environments , 2017 .

[149]  Peter G. Martin,et al.  Radiological Mapping of Post-Disaster Nuclear Environments Using Fixed-Wing Unmanned Aerial Systems: A Study From Chornobyl , 2020, Frontiers in Robotics and AI.

[150]  Pablo Royo,et al.  An Unmanned Aircraft System to Detect a Radiological Point Source Using RIMA Software Architecture , 2018, Remote. Sens..

[151]  Anirban Mazumdar,et al.  A ball-shaped underwater robot for direct inspection of nuclear reactors and other water-filled infrastructure , 2013, 2013 IEEE International Conference on Robotics and Automation.

[152]  Kevin Kochersberger,et al.  Radiation Mapping in Post-Disaster Environments Using an Autonomous Helicopter , 2012, Remote. Sens..

[153]  Josué Jr. Guimarães Ramos,et al.  A semi-autonomous robotic airship for environmental monitoring missions , 1998, Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146).

[154]  Stefano Caselli,et al.  Detection of Nuclear Sources by UAV Teleoperation Using a Visuo-Haptic Augmented Reality Interface , 2017, Sensors.

[155]  Atef Mohany,et al.  Development of a semi-autonomous directional and spectroscopic radiation detection mobile platform , 2015 .

[156]  M. Lozano,et al.  Response of the REWARD detection system to the presence of a Radiological Dispersal Device , 2015, 2015 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA).

[157]  Kenji Shimazoe,et al.  A prototype of aerial radiation monitoring system using an unmanned helicopter mounting a GAGG scintillator Compton camera , 2016 .

[158]  Myoungho Kim,et al.  Aerial working environment monitoring robot in high radiation area , 2014, 2014 14th International Conference on Control, Automation and Systems (ICCAS 2014).

[159]  S. Mattsson,et al.  Tests of HPGe- and scintillation-based backpack γ-radiation survey systems. , 2014, Journal of Environmental Radioactivity.

[160]  M. Bruggeman,et al.  Airborne concentrations and chemical considerations of radioactive ruthenium from an undeclared major nuclear release in 2017 , 2019, Proceedings of the National Academy of Sciences.

[161]  P. Peerani,et al.  Scintilla European project, the successful research results , 2015, 2015 4th International Conference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA).

[162]  Sheldon Landsberger,et al.  Mobile Robotic Radiation Surveying Using Recursive Bayesian Estimation , 2019, 2019 IEEE 15th International Conference on Automation Science and Engineering (CASE).

[163]  Andrew Haefner,et al.  Handheld real-time volumetric 3-D gamma-ray imaging , 2017 .

[165]  Clair J. Sullivan Radioactive source localization in urban environments with sensor networks and the Internet of Things , 2016, 2016 IEEE International Conference on Multisensor Fusion and Integration for Intelligent Systems (MFI).

[166]  R. Thiruvengadathan,et al.  Advances in detection algorithms for radiation monitoring. , 2020, Journal of environmental radioactivity.

[167]  Shinji Ohsuka,et al.  Handy Compton camera using 3D position-sensitive scintillators coupled with large-area monolithic MPPC arrays , 2013 .

[168]  Chaohui He,et al.  A detector system for searching lost γ-ray source , 2020 .

[169]  Josué Jr. Guimarães Ramos,et al.  Project AURORA: Infrastructure and flight control experiments for a robotic airship , 2006, J. Field Robotics.

[170]  N. Hengartner,et al.  Tomographic Imaging with Cosmic Ray Muons , 2008 .

[171]  Attribution of gamma-ray background collected by a mobile detector system to its surroundings using panoramic video , 2020 .

[172]  L. Sihver,et al.  Radiation environment at aviation altitudes and in space. , 2015, Radiation protection dosimetry.

[173]  G. Knoll Radiation Detection And Measurement, 3rd Ed , 2009 .