Signal analysis of acoustic and flow-induced vibrations of BWR main steam line

Abstract The aim of this work is the signal analysis of acoustic waves due to phenomenon known as singing in Safety Relief Valves (SRV) of the main steam lines (MSL) in a typical BWR5. The acoustic resonance in SRV standpipes and fluctuating pressure is propagated from SRV to the dryer through the MSL. The signals are analyzed with a novel method based on the Multivariate Empirical Mode Decomposition (M-EMD). The M-EMD algorithm has the potential to find common oscillatory modes (IMF) within multivariate data. Based on this fact, we implement the M-EMD technique to find the oscillatory mode in BWR considering the measurements obtained collected by the strain gauges located around the MSL. These IMF, analyzed simultaneously in time, allow obtaining an estimation of the effects of the multiple-SRV in the MSL. Two scenarios are analyzed: the first is the signal obtained before the installation of the acoustic dampers (ASB), and the second, the signal obtained after installation. The results show the effectiveness of the ASB to damp the strong resonances when the steam flow increases, which represents an important reduction in the acoustic loads to the steam dryer.

[1]  P. Tse,et al.  An improved Hilbert–Huang transform and its application in vibration signal analysis , 2005 .

[2]  Gabriel Rilling,et al.  Bivariate Empirical Mode Decomposition , 2007, IEEE Signal Processing Letters.

[3]  Yann Le Moigne,et al.  BWR steam dryer for extended power uprate , 2008 .

[4]  Samir Ziada,et al.  STROUHAL NUMBERS OF FLOW-EXCITED ACOUSTIC RESONANCE OF CLOSED SIDE BRANCHES , 1999 .

[5]  Daniel V. Sommerville Scaling Laws for Model Test Based BWR Steam Dryer Fluctuating Load Definitions , 2006 .

[6]  Pi-Cheng Tung,et al.  Data analysis using a combination of independent component analysis and empirical mode decomposition. , 2009, Physical review. E, Statistical, nonlinear, and soft matter physics.

[7]  G. Espinosa-Paredes,et al.  Current status of steam dryer performance under power uprate in Boiling Water Reactors , 2014 .

[8]  Richard Kronland-Martinet,et al.  Asymptotic wavelet and Gabor analysis: Extraction of instantaneous frequencies , 1992, IEEE Trans. Inf. Theory.

[9]  Toshihisa Tanaka,et al.  Complex Empirical Mode Decomposition , 2007, IEEE Signal Processing Letters.

[10]  N. Huang,et al.  The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis , 1998, Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[11]  M. Murase,et al.  Development of Simplified Wave-type Vane in BWR Steam Dryer and Assessment of Vane Droplet Removal Characteristics , 1999 .

[12]  Samir Ziada,et al.  Flow-Excited Acoustic Resonance in Industry , 2010 .

[13]  I. K. Kwang,et al.  All-fiber acousto-optic tunable notch filter with electronically controllable spectral profile. , 1997, Optics letters.

[14]  R. M. Baldwin,et al.  Flow-Induced Vibration in Safety Relief Valves , 1986 .

[15]  Thierry Chonavel,et al.  Audio encoding based on the Empirical Mode Decomposition , 2009, 2009 17th European Signal Processing Conference.

[16]  Norden E. Huang,et al.  A review on Hilbert‐Huang transform: Method and its applications to geophysical studies , 2008 .

[17]  Arye Nehorai A minimal parameter adaptive notch filter with constrained poles and zeros , 1985, IEEE Trans. Acoust. Speech Signal Process..

[18]  O. Eisen,et al.  Ground‐based measurements of spatial and temporal variability of snow accumulation in East Antarctica , 2008 .

[19]  D. P. Mandic,et al.  Multivariate empirical mode decomposition , 2010, Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[20]  Shiro Takahashi,et al.  Experimental Study of Acoustic and Flow-Induced Vibrations in BWR Main Steam Lines and Steam Dryers , 2008 .

[21]  Ryo Morita,et al.  Evaluation of Acoustic- and Flow-Induced Vibration of the BWR Main Steam Lines and Dryer , 2011 .

[22]  D. Tonon,et al.  Flow-induced pulsations in pipe systems with closed side branches: study of the effectiveness of detuning as remedial measure , 2010 .