Imageless computer navigation for placement of the femoral component in resurfacing arthroplasty of the hip.

We have investigated the accuracy of placement of the femoral component using imageless navigation in 100 consecutive Birmingham Hip Resurfacings. Pre-operative templating determined the native neck-shaft angle and planned stem-shaft angle of the implant. The latter were verified post-operatively using digital anteroposterior unilateral radiographs of the hip. The mean neck-shaft angle determined before operation was 132.7 degrees (118 degrees to 160 degrees ). The mean planned stem-shaft angle was a relative valgus alignment of 9.7 degrees (SD 2.6). The stem-shaft angle after operation differed from that planned by a mean of 2.8 degrees (SD 2.0) and in 86% of cases the final angle measured within +/- 5 degrees of that planned. We had no instances of notching of the neck or varus alignment of the implant in our series. A learning curve was observed in the time taken for navigation, but not for accurate placement of the implant. Navigation in hip resurfacing may afford the surgeon a reliable and accurate method of placement of the femoral component.

[1]  E. Schemitsch,et al.  The reliability of radiographic assessment of femoral neck-shaft and implant angulation in hip resurfacing arthroplasty. , 2009, The Journal of arthroplasty.

[2]  D. Morgan,et al.  Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty. , 2009, The Journal of arthroplasty.

[3]  Andrea Emilio Salvi Letter to the Editor: Femoral Component Positioning in Hip Resurfacing with and Without Navigation , 2009, Clinical orthopaedics and related research.

[4]  R Zdero,et al.  Femoral neck fracture following hip resurfacing: the effect of alignment of the femoral component. , 2008, The Journal of bone and joint surgery. British volume.

[5]  M. Swank,et al.  Imageless navigation in hip resurfacing: avoiding component malposition during the surgeon learning curve. , 2008, The Journal of bone and joint surgery. American volume.

[6]  T. Seyler,et al.  Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. , 2008, The Journal of bone and joint surgery. American volume.

[7]  D. Zukor,et al.  Risk of periprosthetic femoral neck fracture after hip resurfacing arthroplasty: valgus compared with anatomic alignment. A biomechanical and clinical analysis. , 2008, The Journal of bone and joint surgery. American volume.

[8]  D J Beard,et al.  The five-year results of the Birmingham Hip Resurfacing arthroplasty: an independent series. , 2008, The Journal of bone and joint surgery. British volume.

[9]  D. König,et al.  Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy , 2009, International Orthopaedics.

[10]  V. Goldberg,et al.  Effect of Changing Indications and Techniques on Total Hip Resurfacing , 2007, Clinical orthopaedics and related research.

[11]  C. Hing,et al.  The results of primary Birmingham hip resurfacings at a mean of five years. An independent prospective review of the first 230 hips. , 2007, The Journal of bone and joint surgery. British volume.

[12]  T. Seyler,et al.  Femoral neck fractures after metal-on-metal total hip resurfacing: a prospective cohort study. , 2007, The Journal of arthroplasty.

[13]  N. Helmy,et al.  Comparative repeatability of guide-pin axis positioning in computer-assisted and manual femoral head resurfacing arthroplasty , 2007, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[14]  A. Hodgson,et al.  Hip Resurfacing Femoral Neck Fracture Influenced by Valgus Placement , 2007, Clinical orthopaedics and related research.

[15]  J. Cobb,et al.  Navigation Reduces the Learning Curve in Resurfacing Total Hip Arthroplasty , 2007, Clinical orthopaedics and related research.

[16]  P Gallie,et al.  The accuracy of image-free computer navigation in the placement of the femoral component of the Birmingham Hip Resurfacing: a cadaver study. , 2007, The Journal of bone and joint surgery. British volume.

[17]  B L Davies,et al.  Computer-assisted hip resurfacing surgery using the Acrobot® Navigation System , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[18]  F M Rodriguez y Baena,et al.  Preoperative planning and intraoperative guidance for accurate computer-assisted minimally invasive hip resurfacing surgery , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[19]  S. Maubach,et al.  Lessons learned from early clinical experience and results of 300 ASR® hip resurfacing implantations , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[20]  D. Mcminn,et al.  History and modern concepts in surface replacement , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[21]  Koen De Smet,et al.  Belgium experience with metal-on-metal surface arthroplasty. , 2005 .

[22]  D. Back,et al.  Femoral neck fractures following Birmingham hip resurfacing: a national review of 50 cases. , 2005, The Journal of bone and joint surgery. British volume.

[23]  J Bare,et al.  Complications associated with hip resurfacing arthroplasty. , 2005, The Orthopedic clinics of North America.

[24]  A Shimmin,et al.  Early results of primary Birmingham hip resurfacings. An independent prospective study of the first 230 hips. , 2005, The Journal of bone and joint surgery. British volume.

[25]  P B Pynsent,et al.  Birmingham hip resurfacing arthroplasty. A minimum follow-up of five years. , 2005, The Journal of bone and joint surgery. British volume.

[26]  A. Hodgson,et al.  Computer-assisted femoral head resurfacing , 2005, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[27]  H. Amstutz,et al.  Orientation of the femoral component in surface arthroplasty of the hip. , 2004, The Journal of bone and joint surgery. American volume.

[28]  K. D. De Smet Belgium experience with metal-on-metal surface arthroplasty. , 2005, The Orthopedic clinics of North America.

[29]  T. Hess,et al.  Einsatz der Navigation beim Oberflächenersatz des Hüftgelenks , 2004, Der Orthopäde.

[30]  H. Amstutz,et al.  Fracture of the neck of the femur after surface arthroplasty of the hip. , 2004, The Journal of bone and joint surgery. American volume.

[31]  H. Amstutz,et al.  Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis. , 2004, The Journal of bone and joint surgery. American volume.

[32]  P B Pynsent,et al.  Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. , 2004, The Journal of bone and joint surgery. British volume.

[33]  P. Beaulé,et al.  Risk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip , 2004, Clinical orthopaedics and related research.

[34]  T. Gampe,et al.  [Intraoperative navigation for hip resurfacing. Methods and first results]. , 2004, Der Orthopade.

[35]  P. Campbell,et al.  Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study. , 2004, The Journal of bone and joint surgery. American volume.

[36]  G. Fabry Femoral anteversion and neck shaft angle in children with cerebral palsy. , 2000, Clinical orthopaedics and related research.

[37]  R. Kay,et al.  The Effect of Femoral Rotation on the Projected Femoral Neck-Shaft Angle , 2000, Journal of pediatric orthopedics.

[38]  R. Bilić,et al.  Assessment of femoral neck-shaft and antetorsion angles , 1997, International Orthopaedics.

[39]  Y. Yoshioka,et al.  The anatomy and functional axes of the femur. , 1987, The Journal of bone and joint surgery. American volume.

[40]  D B Burr,et al.  Measurement Accuracy of Proximal Femoral Geometry Using Biplanar Radiography , 1981, Journal of pediatric orthopedics.

[41]  Freeman Ma Total surface replacement hip arthroplasty. , 1978 .

[42]  M. Freeman Total surface replacement hip arthroplasty. , 1978, Clinical orthopaedics and related research.