A new Pinnacle 3D treatment‐planning system software release has recently become available (v7.4, Philips Radiation Oncology Systems, Milpitas, CA), which supports modeling of rounded multileaf collimator (MLC) leaf ends; it also includes a number of other software enhancements intended to improve the overall dose calculation accuracy. In this report, we provide a general discussion of the dose calculation algorithm and new beam‐modeling parameters. The accuracy of a diode dosimeter was established for measurement of MLC‐shaped beam profiles required by the new software version by comparison with film and ion chamber measurements in various regions of the field. The results suggest that a suitable diode or other small volume dosimeter with appropriate energy sensitivity should be used to obtain profiles for commissioning the planning system. Film should be used with caution, especially for larger field profile measurements. The dose calculation algorithm and modeling parameters chosen were validated through various test field measurements including a bar pattern, a strip pattern, and a clinical head and neck IMRT field. For the bar and strip patterns, the agreement between Pinnacle calculations and diode measurements was generally very good. These tests were helpful in establishing the new model parameter values, especially tongue‐and‐groove width, additional interleaf leakage, rounded leaf tip radius, and MLC transmission. For the clinical head and neck field, the comparison between Pinnacle and film measurements showed regions of approximately 2 cGy under‐ or overdose. However, the Pinnacle calculations agreed with diode measurements at all points to within 1 cGy or 1% of the maximum dose for the field (67 cGy). The greatest discrepancy between film and diode measurements for the clinical field (maximum of 2.8%) occurred in low‐dose regions in the central part of the field. The disagreement may be due to the overresponse of film to scattered radiation in the low‐dose regions, which have significant shielding by the MLCs. PACS numbers: 87.53.Bn, 87.53.Dq
[1]
R Mohan,et al.
Energy and angular distributions of photons from medical linear accelerators.
,
1985,
Medical physics.
[2]
J. Battista,et al.
A convolution method of calculating dose for 15-MV x rays.
,
1985,
Medical physics.
[3]
N Papanikolaou,et al.
Investigation of the convolution method for polyenergetic spectra.
,
1993,
Medical physics.
[4]
A. Ahnesjö,et al.
Dose calculations for external photon beams in radiotherapy.
,
1999,
Physics in medicine and biology.
[5]
A. Brahme,et al.
Comparative dosimetry in narrow high-energy photon beams.
,
2000,
Physics in medicine and biology.
[6]
I. Rosen,et al.
Beam‐commissioning methodology for a three‐dimensional convolution/superposition photon dose algorithm
,
2000,
Journal of applied clinical medical physics.
[7]
Lei Dong,et al.
Rapid radiographic film calibration for IMRT verification using automated MLC fields.
,
2002,
Medical physics.
[8]
G. Ibbott,et al.
Dosimetric considerations for validation of a sequential IMRT process with a commercial treatment planning system.
,
2002,
Physics in medicine and biology.
[9]
W. Laub,et al.
The volume effect of detectors in the dosimetry of small fields used in IMRT.
,
2003,
Medical physics.