High-resolution alpha-particle spectrometry using 4H silicon carbide semiconductor detectors

SiC detectors with active volume dimensions sufficient to stop alpha particles have been manufactured and tested. A linear energy response and excellent energy resolution have been obtained for various alpha emitters in the 3.18-MeV to 8.38-MeV energy range. Evaluation of the contributing factors to the SiC detector energy resolution indicates that the measured values for the full width at half maximum (FWHM) are limited by energy straggling of the alpha particles as they pass through the metallic contact layers that comprise the entrance window to the detector. Even with this component included in the measured FWHM, the measured values are comparable to those achievable with silicon alpha spectrometers. The possibility that the energy resolution that can be achieved with SiC may surpass that of silicon can not be excluded. SiC alpha spectrometers are expected to be useful in many nuclear applications where the ability to operate in high-temperature and high-radiation environments is required. Such applications include monitoring of alpha particles, neutrons, and low-energy gamma rays and X-rays in actinide waste-tank environments as well as neutron and gamma-ray monitoring of spent nuclear fuel assemblies.

[1]  B. Petrovic,et al.  FAST NEUTRON SPECTROMETRY USING SILICON CARBIDE DETECTORS , 2003 .

[2]  Giuseppe Bertuccio,et al.  Study of silicon carbide for X-ray detection and spectroscopy , 2003 .

[3]  Frank H. Ruddy,et al.  Demonstration of an SiC neutron detector for high-radiation environments , 1999 .

[4]  John W. Palmour,et al.  The charged particle response of silicon carbide semiconductor radiation detectors , 2003 .

[5]  C. W. Struck,et al.  Scattering by ionization and phonon emission in semiconductors , 1980 .

[6]  G. Knoll Radiation detection and measurement , 1979 .

[7]  Claudio Lanzieri,et al.  A new generation of X-ray detectors based on silicon carbide , 2004 .

[8]  Frank H. Ruddy,et al.  Development of a silicon carbide radiation detector , 1998 .

[9]  M. Syväjärvi,et al.  The limiting energy resolution of SiC detectors in ion spectrometry , 2005 .

[10]  C. Canali,et al.  Epitaxial silicon carbide charge particle detectors , 1999 .

[11]  F. Ruddy,et al.  The effects of intense gamma-irradiation on the alpha-particle response of silicon carbide semiconductor radiation detectors , 2007 .

[12]  Jeffrey A. Koch,et al.  A neutron sensor based on single crystal CVD diamond , 2004 .

[13]  G. De Geronimo,et al.  Silicon carbide pin diodes as radiation detectors , 2005, IEEE Nuclear Science Symposium Conference Record, 2005.

[14]  H. Endo,et al.  Measurement of the Fano factor for protons on silicon , 1979 .

[15]  C. Davison,et al.  Neutron and Gamma Ray Dosimetry in Spent-Fuel Radiation Environments Using Silicon Carbide Semiconductor Radiation Detectors , 2001 .

[16]  F. H. Ruddy,et al.  Spent Fuel Monitoring with Silicon Carbide Semiconductor Neutron/Gamma Detectors , 2006 .

[17]  U. Fano Ionization Yield of Radiations. II. The Fluctuations of the Number of Ions , 1947 .