Efficiency of injected anchors in masonry elements: Evaluation of pull-out strength

Abstract Injected anchors in masonry elements represent a widespread technique for improving the ‘box behavior’ of masonry structures, since they contribute to avoid or delay out-of-plane mechanisms under horizontal actions. Despite of their diffusion, no clear design indications for injected anchors are available in literature and codes. This paper is aimed to propose design formulations for the maximum pull-out force in injected anchors basing on wide numerical analyses realized through a 2D Finite Element (FE) model specifically tuned to simulate pull-out tests. Thanks to the variation of several parameters, the most significant ones influencing the maximum pull-out force are identified and introduced in the strength models and several coefficients are assessed through best fitting regression analyses carried out on the numerical results. Finally, based on a ‘design by testing’ approach, preliminar 5% percentile provisions for the maximum pull-out force are proposed too, and the reliability of the ‘design-oriented’ formulation is assessed by means of comparisons with experimental results of some pull-out tests available in literature.

[1]  Francesca Ceroni,et al.  Assessment of performance of steel and GFRP bars as injected anchors in masonry walls , 2016 .

[2]  Andrea Prota,et al.  Out-of-plane experimental behaviour of T-shaped full scale masonry wall strengthened with composite connections , 2016 .

[3]  Manicka Dhanasekar,et al.  Modelling the failure of thin layered mortar joints in masonry , 2013 .

[4]  Mijia Yang,et al.  Bond mechanism and bond strength of GFRP bars to concrete: A review , 2016 .

[5]  H Shakir-Khalil,et al.  PUSHOUT STRENGTH OF CONCRETE-FILLED STEEL HOLLOW SECTION TUBES , 1993 .

[6]  Charles L. Bartholomew,et al.  FRP Reinforcing Bars in Reinforced Concrete Members , 1993 .

[7]  Paulo B. Lourenço,et al.  Numerical study on the performance of improved masonry-to-timber connections in traditional masonry buildings , 2014 .

[9]  B. G. Rabbat,et al.  Friction Coefficient of Steel on Concrete or Grout , 1985 .

[11]  M. Fagone,et al.  Round Robin Test on tensile and bond behaviour of Steel Reinforced Grout systems , 2017 .

[12]  Paulo B. Lourenço,et al.  Analysis of Masonry Structures Without Box Behavior , 2011 .

[13]  Maria Rosa Valluzzi,et al.  On-Site Pull-Out Tests of Steel Anchor Spikes Applied to Brickwork Masonry , 2014 .

[14]  Simona Voto,et al.  Historical, Architectural, and Structural Assessment of the Bell Tower of Santa Maria Del Carmine , 2009 .

[15]  Youn Ju Jeong,et al.  Steel-concrete interface behavior and analysis for push-out , 2005 .

[16]  Dina D'Ayala,et al.  Testing and design procedure for corner connections of masonry heritage buildings strengthened by metallic grouted anchors , 2014 .

[17]  Dong-Ho Ha,et al.  Mechanical properties of constitutive parameters in steel-concrete interface , 2011 .

[18]  Paulo B. Lourenço,et al.  Experimental behavior of masonry wall-to-timber elements connections strengthened with injection anchors , 2014 .

[19]  F. Xing,et al.  Shear strength components of adjustable hybrid bonded CFRP shear-strengthened RC beams , 2019, Composites Part B: Engineering.

[20]  Marco Di Ludovico,et al.  Traditional and innovative systems for injected anchors in masonry elements: Experimental behavior and theoretical formulations , 2020 .

[21]  H. Saadatmanesh,et al.  Design Recommendations for Bond of GFRP Rebars to Concrete , 1996 .

[22]  Sinan Altin,et al.  Hysteretic behavior of RC shear walls strengthened with CFRP strips , 2013 .

[23]  N. Augenti,et al.  Constitutive modelling of tuff masonry in direct shear , 2011 .

[24]  Hiroshi Shima,et al.  RECOMMENDATION FOR DESIGN AND CONSTRUCTION OF CONCRETE STRUCTURES USING CONTINUOUS FIBER REINFORCING MATERIALS (DESIGN) , 1997 .

[25]  Andrea Prota,et al.  Case Study: Seismic Upgrade of a Masonry Bell Tower Using Glass Fiber-Reinforced Polymer Ties , 2009 .

[26]  Ronald A. Cook Behavior of Chemically Bonded Anchors , 1993 .

[28]  Carol K. Shield,et al.  Development Length of Glass Fiber-Reinforced Polymer Bars in Concrete , 2006 .

[29]  Antonio Borri,et al.  Shear strengthening of wall panels through jacketing with cement mortar reinforced by GFRP grids , 2014 .

[30]  Emidio Nigro,et al.  Bond of NSM FRP-strengthened concrete: round robin test initiative , 2016 .

[31]  Silvia Santini,et al.  Design by testing: A procedure for the statistical determination of capacity models , 2009 .

[32]  Paolo Riva,et al.  Experimental Study on Injected Anchors for the Seismic Retrofit of Historical Masonry Buildings , 2015 .

[33]  G. Manfredi,et al.  Development length of FRP straight rebars , 2002 .

[34]  Subhamoy Bhattacharya,et al.  A critical review of retrofitting methods for unreinforced masonry structures , 2014 .