Near-infrared spectral data transfer using independent standardization samples: a case study on the trans-alkylation process

Abstract A variety of standardization or transfer methods between near infrared spectrometric instruments are applied for the content prediction of five major constituents of the product at trans-alkylation process with spectra measured on two different instruments. Because process samples are difficult to be stored, we use independent transfer samples by blending some pure materials for the spectrum standardization of the process samples. Using the independent standardization samples, we investigate the transfer performance of well-known piecewise direct standardization combined with several regression methods on the raw spectra. Also, we propose some indirect standardization methods utilizing wavelet transferred scores or factor scores through principal component analysis and partial least squares. The standardization by transferring scores takes only a few transfer coefficients, but it shows similar performance to the spectrum transfer case. In addition, we show the possibility of using a fewer number of stable samples than the original set of samples for the standardization with similar performance.

[1]  Philip K. Hopke,et al.  Calibration transfer as a data reconstruction problem , 1999 .

[3]  C. Chui Wavelets: A Mathematical Tool for Signal Analysis , 1997 .

[4]  Lutgarde M. C. Buydens,et al.  Improvement of PLS model transferability by robust wavelength selection , 1998 .

[5]  Ingrid Daubechies,et al.  Ten Lectures on Wavelets , 1992 .

[6]  Desire L. Massart,et al.  Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration , 1996 .

[7]  Desire L. Massart,et al.  Standardization of near-infrared spectra in the wavelet domain , 1997 .

[8]  Modelling near infrared instrument differences by chemometric methods: testing for near infrared forage analysis , 1997 .

[9]  D. Massart,et al.  Standardisation of near-infrared spectrometric instruments: A review , 1996 .

[10]  L. A. Stone,et al.  Computer Aided Design of Experiments , 1969 .

[11]  J. Shenk,et al.  New Standardization and Calibration Procedures for Nirs Analytical Systems , 1991 .

[12]  Chris W. Brown,et al.  Calibration Transfer from Sample Cell to Fiber-Optic Probe , 1997 .

[13]  Steven D. Brown,et al.  Standardization of Fiber-Optic Probes for Near-Infrared Multivariate Calibrations , 1998 .

[14]  Bruce R. Kowalski,et al.  Calibration Transfer and Measurement Stability of Near-Infrared Spectrometers , 1992 .

[15]  B. Kowalski,et al.  Multivariate instrument standardization , 1991 .

[16]  Olof Svensson,et al.  An evaluation of orthogonal signal correction applied to calibration transfer of near infrared spectra , 1998 .

[17]  M. Forina,et al.  Transfer of calibration function in near-infrared spectroscopy , 1995 .

[18]  Ronald D. Snee,et al.  Validation of Regression Models: Methods and Examples , 1977 .