Human iris three-dimensional imaging at micron resolution by a micro-plenoptic camera.

A micro-plenoptic system was designed to capture the three-dimensional (3D) topography of the anterior iris surface by simple single-shot imaging. Within a depth-of-field of 2.4 mm, depth resolution of 10 µm can be achieved with accuracy (systematic errors) and precision (random errors) below 20%. We demonstrated the application of our micro-plenoptic imaging system on two healthy irides, an iris with naevi, and an iris with melanoma. The ridges and folds, with height differences of 10~80 µm, on the healthy irides can be effectively captured. The front surface on the iris naevi was flat, and the iris melanoma was 50 ± 10 µm higher than the surrounding iris. The micro-plenoptic imaging system has great potential to be utilized for iris disease diagnosis and continuing, simple monitoring.

[1]  R J Collier,et al.  Recording and Reconstructing Three-Dimensional Images of Computer-Generated Subjects by Lippmann ntegral Photography. , 1968, Applied optics.

[2]  Stephan Hussmann,et al.  Automated Robust Metric Calibration Algorithm for Multifocus Plenoptic Cameras , 2016, IEEE Transactions on Instrumentation and Measurement.

[3]  F. Foster,et al.  Clinical use of ultrasound biomicroscopy. , 1991, Ophthalmology.

[4]  John R. Campbell,et al.  Intraoperative floppy iris syndrome associated with tamsulosin , 2005, Journal of cataract and refractive surgery.

[5]  Hao Chen,et al.  Three-Dimensional Three-Component Air Flow Visualization in a Steady-State Engine Flow Bench Using a Plenoptic Camera , 2017 .

[6]  Hao Chen,et al.  Three-dimensional spray–flow interaction in a spark-ignition direct-injection engine , 2016 .

[7]  C. Shields,et al.  Assessment of anterior segment tumors with ultrasound biomicroscopy versus anterior segment optical coherence tomography in 200 cases. , 2011, Ophthalmology.

[8]  Aaron Fenster,et al.  Three-dimensional ultrasound imaging of the eye , 1996, Eye.

[9]  Uwe Stilla,et al.  Depth estimation and camera calibration of a focused plenoptic camera for visual odometry , 2016 .

[10]  J. Izatt,et al.  Real-time optical coherence tomography of the anterior segment at 1310 nm. , 2001, Archives of ophthalmology.

[11]  Edward H. Adelson,et al.  Single Lens Stereo with a Plenoptic Camera , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[12]  M. Levoy,et al.  Light field microscopy , 2006, SIGGRAPH 2006.

[13]  E A Swanson,et al.  Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography. , 1994, Archives of ophthalmology.

[14]  P. Henkind,et al.  Neovascularization of the iris (rubeosis iridis). , 1978, Survey of ophthalmology.

[15]  James G. Fujimoto,et al.  Enhanced Vitreous Imaging in Healthy Eyes Using Swept Source Optical Coherence Tomography , 2014, PloS one.

[16]  Marc Levoy,et al.  Light Fields and Computational Imaging , 2006, Computer.