The modern era of orthotics

The past 40 years has seen the field of orthotics change from a craft-based industry into a modern clinical specialty. The author describes his personal view of some of the most important developments during this period in the areas of manufacturing and materials, patient/orthosis matching, biomechanics, joint design and standards. Some likely areas of future development are suggested.

[1]  R. Douglas,et al.  The LSU Reciprocation-Gait Orthosis. , 1983, Orthopedics.

[2]  Christopher Barry Meadows The influence of polypropylene ankle-foot orthoses on the gait of cerebral palsied children , 1984 .

[3]  J. Lehmann,et al.  Restraining forces in various designs of knee ankle orthoses: their placement and effect on the anatomical knee joint. , 1976, Archives of physical medicine and rehabilitation.

[4]  P. Bowker,et al.  Biomechanical basis of orthotic management , 1993 .

[5]  Lehmann Jf,et al.  Restraining forces in various designs of knee ankle orthoses: their placement and effect on the anatomical knee joint. , 1976 .

[6]  Stefania Fatone,et al.  A Review of the Literature Pertaining to KAFOs and HKAFOs for Ambulation , 2006 .

[7]  John D. Hsu,et al.  AAOS Atlas of Orthoses and Assistive Devices , 2008 .

[8]  A V Nene,et al.  Energy cost of paraplegic locomotion using the ParaWalker--electrical stimulation "hybrid" orthosis. , 1990, Archives of physical medicine and rehabilitation.

[9]  J. Hsu,et al.  Atlas of orthoses and assistive devices , 1997 .

[10]  J. Geertzen,et al.  Development of Clinical Guidelines for the Prescription of Orthoses in Patients with Neurological Disorders in The Netherlands , 2006, Prosthetics and orthotics international.

[11]  J P Paul,et al.  Hybrid FES orthosis incorporating closed loop control and sensory feedback. , 1988, Journal of biomedical engineering.

[12]  Nene Av,et al.  Energy cost of paraplegic locomotion using the ParaWalker--electrical stimulation "hybrid" orthosis. , 1990 .

[13]  B. Andrews,et al.  Augmentation of the Oswestry Parawalker orthosis by means of surface electrical stimulation: gait analysis of three patients , 1987, Paraplegia.

[14]  J. Michael,et al.  Summary from the Academy's Seventh State -of -the -Science Conference on Knee-Ankle-Foot Orthoses for Ambulation , 2006 .

[15]  Steve West,et al.  Biomechanical basis of orthotic management , 1995 .

[16]  J Stallard,et al.  The dynamics of walking using the hip guidance orthosis (hgo) with crutches , 1981, Prosthetics and orthotics international.

[17]  G K Rose The principles and practice of hip guidance articulations∗ , 1979, Prosthetics and orthotics international.

[18]  C G Warren,et al.  A biomechanical evaluation of knee stability in below knee braces. , 1970, Archives of physical medicine and rehabilitation.