Considerations for Using Harmonic Blocking and Harmonic Restraint Techniques on Transformer Differential Relays

The terms “harmonic restraint” and “harmonic blocking” are sometimes used interchangeably when talking about transformer differential protection. This paper explores the meanings of these terms and how these techniques are individually applied in modern transformer differential relays, including how these techniques affect the speed and security of transformer differential protection. The paper further compares these techniques using examples to show their response to several transformer inrush examples. Editorial Note—Guzman, Benmouyal, Zocholl, and Altuve prepared and presented a paper titled “Performance Analysis of Traditional and Improved Transformer Differential Protective Relays” [1] that provides a thorough discussion about percentage restraint current differential relays and the history and background surrounding the use of harmonics in these relays. Portions of that paper covering selected historical and fundamental background issues are used in this paper to reintroduce this subject for the reader’s convenience.

[1]  W. K. Sonnemann,et al.  Current transformers and relays for high-speed differential protection, with particular reference to offset transient currents , 1940, Electrical Engineering.

[2]  Grigoriĭ Iosifovich Atabekov The relay protection of high voltage networks , 1960 .

[3]  D. E. Marshall,et al.  Current Transformer Excitation Under Transit Conditions , 1929, Transactions of the American Institute of Electrical Engineers.

[4]  E. L. Harder,et al.  Principles and Practices of Relaying in the United States , 1948, Transactions of the American Institute of Electrical Engineers.

[5]  S. E. Zocholl,et al.  Transformer modeling as applied to differential protection , 1996, Proceedings of 1996 Canadian Conference on Electrical and Computer Engineering.

[6]  G. D. Rockefeller,et al.  Fault Protection with a Digital Computer , 1969 .

[7]  Armando Guzman,et al.  Performance Analysis of Traditional and Improved Transformer Differential Protective Relays , 2000 .

[8]  W. E. Glassburn,et al.  A Transformer Differential Relay with Second-Harmonic Restraint , 1958, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[9]  I. T. Monseth,et al.  Relay systems : theory and application , 1935 .

[10]  R. E. Cordray,et al.  Percentage-differential transformer protection , 1931, Electrical Engineering.

[11]  G. D. Rockefeller,et al.  Magnetizing Inrush Phenomena in Transformer Banks , 1958, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[12]  C. A. Mathews An Improved Transformer Differential Relay [includes discussion] , 1954, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.

[13]  C.-H. Einvall,et al.  A three-phase differential relay for transformer protection , 1975, IEEE Transactions on Power Apparatus and Systems.

[14]  C. D. Hayward Harmonic-Current-Restrained Relays for Transformer Differential Protection , 1941, Transactions of the American Institute of Electrical Engineers.

[15]  C. A. Mathews An improved transformer differential relay , 1954, Electrical Engineering.

[16]  C. Concordia,et al.  Transient Characteristics of Current Transformers During Faults , 1942, Transactions of the American Institute of Electrical Engineers.

[17]  L. F. Kennedy,et al.  Harmonic-Current-Restrained Relays for Differential Protection , 1938, Transactions of the American Institute of Electrical Engineers.