Fullerene derived molecularly imprinted polymer for chemosensing of adenosine-5'-triphosphate (ATP).

For molecular imprinting of oxidatively electroactive analytes by electropolymerization, we used herein reductively electroactive functional monomers. As a proof of concept, we applied C60 fullerene adducts as such for the first time. For that, we derivatized C60 to bear either an uracil or an amide, or a carboxy addend for recognition of the adenosine-5'-triphosphate (ATP) oxidizable analyte with the ATP-templated molecularly imprinted polymer (MIP-ATP). Accordingly, the ATP complex with all of the functional monomers formed in solution was potentiodynamically electropolymerized to deposit an MIP-ATP film either on an Au electrode of the quartz crystal resonator or on a Pt disk electrode for the piezoelectric microgravimetry (PM) or capacitive impedimetry (CI) determination of ATP, respectively, under the flow-injection analysis (FIA) conditions. The apparent imprinting factor for ATP was ∼4.0. After extraction of the ATP template, analytical performance of the resulting chemosensors, including detectability, sensitivity, and selectivity, was characterized. The limit of detection was 0.3 and 0.03mM ATP for the PM and CI chemosensor, respectively. The MIP-ATP film discriminated structural analogues of ATP quite well. The Langmuir, Freundlich, and Langmuir-Freundlich isotherms were fitted to the experimental data of the ATP sorption and sorption stability constants appeared to be nearly independent of the adopted sorption model.

[1]  W. Kutner,et al.  Molecularly imprinted polymer of bis(2,2'-bithienyl)methanes for selective determination of adrenaline. , 2013, Bioelectrochemistry.

[2]  J. Knowles Enzyme-catalyzed phosphoryl transfer reactions. , 1980, Annual review of biochemistry.

[3]  Wlodzimierz Kutner,et al.  An improved holder for the electrochemical quartz crystal microbalance and its cyclic voltammetry characteristics , 1993 .

[4]  M. Prato,et al.  Addition of azomethine ylides to C60: synthesis, characterization, and functionalization of fullerene pyrrolidines , 1993 .

[5]  Wlodzimierz Kutner,et al.  Simultaneous chronoamperometry and piezoelectric microgravimetry determination of nitroaromatic explosives using molecularly imprinted thiophene polymers. , 2013, Analytical chemistry.

[6]  K. Winkler,et al.  Formation of Redox-Active, Two-Component Films by Electrochemical Reduction of C60 and Transition Metal Complexes , 1998 .

[7]  M. Szuwarzyński,et al.  Molecularly imprinted hybrid adsorbents for adenine and adenosine-5'-triphosphate. , 2012, Journal of medicinal chemistry.

[8]  N. Sugimoto,et al.  An approach to peptide-based ATP receptors by a combination of random selection, rational design, and molecular imprinting. , 2009, Biosensors & bioelectronics.

[9]  W. Kutner,et al.  Electrochemically synthesized molecularly imprinted polymer of thiophene derivatives for flow-injection analysis determination of adenosine-5'-triphosphate (ATP). , 2013, Biosensors & bioelectronics.

[10]  W. Kutner,et al.  Flow characteristics of a versatile wall‐jet or radial‐flow thin‐layer large‐volume cell for electrochemical detection in flow‐through analytical systems , 1997 .

[11]  Su-Moon Park,et al.  Electrochemical impedance spectroscopy. , 2010, Annual review of analytical chemistry.

[12]  A. Pietrzyk,et al.  Molecularly imprinted poly[bis(2,2'-bithienyl)methane] film with built-in molecular recognition sites for a piezoelectric microgravimetry chemosensor for selective determination of dopamine. , 2010, Bioelectrochemistry.

[13]  D. Guldi,et al.  Hydrogen-bonding motifs in fullerene chemistry. , 2005, Angewandte Chemie.

[14]  W. Kutner,et al.  Conductive, capacitive, and viscoelastic properties of a new composite of the C60-pd conducting polymer and single-wall carbon nanotubes. , 2009, The journal of physical chemistry. B.

[15]  Wlodzimierz Kutner,et al.  Electrocatalytic Properties and Sensor Applications of Fullerenes and Carbon Nanotubes , 2003 .

[16]  W. Kutner,et al.  Electrochemically formed fullerene-based polymeric films , 2006 .

[17]  Maurizio Prato,et al.  Anion recognition by functionalized single wall carbon nanotubes. , 2003, Chemical communications.

[18]  K. Winkler,et al.  Electrochemically formed two-component films comprised of fullerene and transition-metal components , 2006 .

[19]  Petr Skládal,et al.  Piezoelectric quartz crystal sensors applied for bioanalytical assays and characterization of affinity interactions , 2003 .

[20]  R. Sprague,et al.  Impaired Release of ATP from Red Blood Cells of Humans with Primary Pulmonary Hypertension , 2001, Experimental biology and medicine.

[21]  V. T. Hoang,et al.  Molecular recognition of adenine, adenosine and ATP at the air–water interface by a uracil appended fullerene , 2002 .

[22]  J. Rebek,et al.  Exceptionally strong electronic communication through hydrogen bonds in porphyrin-C60 pairs. , 2006, Angewandte Chemie.

[23]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .

[24]  James Noble,et al.  The rational development of molecularly imprinted polymer-based sensors for protein detection. , 2011, Chemical Society reviews.

[25]  A. Brajter-toth,et al.  Selectivity and sensitivity of ultrathin purine-templated overoxidized polypyrrole film electrodes , 1996 .

[26]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[27]  Rigoberto C. Advincula,et al.  Electropolymerized Molecularly Imprinted Polymer Film: EIS Sensing of Bisphenol A , 2011 .

[28]  Wlodzimierz Kutner,et al.  Molecularly imprinted polymer (MIP) based piezoelectric microgravimetry chemosensor for selective determination of adenine. , 2010, Biosensors & bioelectronics.

[29]  M. Zandler,et al.  Through-bond photoinduced electron transfer in a porphyrin-fullerene conjugate held by a Hamilton type hydrogen bonding motif. , 2009, Organic & biomolecular chemistry.

[30]  F. D’Souza,et al.  Redox Active Two‐Component Films of Palladium and Covalently Linked Zinc Porphyrin–Fullerene Dyad , 2006 .

[31]  Sergey A. Piletsky,et al.  MIP sensors – the electrochemical approach , 2012, Analytical and Bioanalytical Chemistry.

[32]  Romana Schirhagl,et al.  Bioapplications for molecularly imprinted polymers. , 2014, Analytical chemistry.

[33]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[34]  Jiri Janata,et al.  Principles of Chemical Sensors , 1989 .

[35]  Florent Breton,et al.  Molecular imprinting of AMP by an ionic-noncovalent dual approach. , 2009, Journal of separation science.

[36]  S. Nigam,et al.  Genesis and reversal of the ischemic phenotype in epithelial cells. , 2000, The Journal of clinical investigation.

[37]  F. D’Souza,et al.  Two-Component Films of Fullerene and Palladium as Materials for Electrochemical Capacitors , 2007 .

[38]  M. Zandler,et al.  Photoinduced electron transfer in a Watson-Crick base-paired, 2-aminopurine:uracil-C60 hydrogen bonding conjugate. , 2007, Chemical communications.

[39]  D. Kang,et al.  Monitoring beef carcass surface microbial contamination with a luminescence-based bacterial phosphatase assay. , 2002, Journal of food protection.

[40]  M. Vila,et al.  MPTP: a review of its mechanisms of neurotoxicity , 2001, Clinical Neuroscience Research.

[41]  J. Wood,et al.  The rapid estimation of microbial contamination of raw meat by measurement of adenosine triphosphate (ATP). , 1983, The Journal of applied bacteriology.

[42]  R. N. Shah,et al.  Characterization of molecularly imprinted polymers with the Langmuir-Freundlich isotherm. , 2001, Analytical chemistry.

[43]  Florent Breton,et al.  Selective adenosine-5'-monophosphate uptake by water-compatible molecularly imprinted polymer. , 2008, Analytica chimica acta.

[44]  W. Kutner,et al.  Design and Performance of a New Thin-Layer Radial-Flow Holder for a Quartz Crystal Resonator of an Electrochemical Quartz Crystal Microbalance , 2006 .

[45]  Gerhard J. Mohr,et al.  Chemosensors based on molecularly imprinted polymers. , 2012, Topics in current chemistry.

[46]  I. Kanno,et al.  Resistance measurements of conducting C 60 monolayers formed on Au and Cu films , 2003 .

[47]  K. Sreenivasan Synthesis and evaluation of multiply templated molecularly imprinted polyaniline , 2007 .

[48]  Atsushi Ikeda,et al.  Saccharide Libraries as Potential Templates for Regio- and Chiroselective Introduction of Two Functional Groups into [60]Fullerene. , 1999, The Journal of organic chemistry.

[49]  A. Soares,et al.  Sensing and analysis of soluble phosphates in environmental samples: a review. , 2013, Biosensors & bioelectronics.

[50]  W. Kutner,et al.  Study of Redox Active C 60 / Pd Films by Simultaneous Cyclic Voltammetry and Piezoelectric Microgravimetry at an Electrochemical Quartz Crystal Microbalance , 2000 .

[51]  M. Syu,et al.  Synthesis and characterization of creatinine imprinted poly(4-vinylpyridine-co-divinylbenzene) as a specific recognition receptor , 2005 .

[52]  O. Soppera,et al.  Photopolymerization and photostructuring of molecularly imprinted polymers for sensor applications , 2012, 2012 IEEE Sensors.

[53]  Marta Elena Díaz-García,et al.  Characterization of binding sites in molecularly imprinted polymers , 2007 .

[54]  W. Kutner,et al.  Electrochemically synthesized polymers in molecular imprinting for chemical sensing , 2012, Analytical and Bioanalytical Chemistry.

[55]  S. Shinkai,et al.  Novel nucleotide‐responsive hydrogels designed from copolymers of boronic acid and cationic units and their applications as a QCM resonator system to nucleotide sensing , 2000 .