A Fast On-Line Diagnostic Method for Open-Circuit Switch Faults in SiC-MOSFET-Based T-Type Multilevel Inverters

On-line condition monitoring is of paramount importance for multilevel power converters used in safety-critical applications. A novel on-line nonintrusive diagnostic method for detecting open-circuit switch faults in silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFETs)-based T-type multilevel converters is introduced in this paper. The principle of this method is based on monitoring the abnormal variations of the dc-bus neutral-point current in combination with the existing information on instantaneous switching states and phase currents. Advantages of this method include faster detection speed and simpler implementation compared to other existing diagnostic methods in the literature. Moreover, this diagnostic method is immune to the disturbances of inverter's dc-bus voltage unbalance and load unbalance. In this method, only one additional current sensor is required for measuring the dc-bus neutral-point current; therefore, the implementation cost is low. Simulation and experimental results based on a lab-scale 20 kVA adjustable speed drive with a three-level SiC T-type inverter validate the effectiveness and robustness of this novel diagnostic method.

[1]  Edith Clarke,et al.  Determination of Instantaneous Currents and Voltages by Means of Alpha, Beta, and Zero Components , 1951, Transactions of the American Institute of Electrical Engineers.

[2]  A. M. S. Mendes,et al.  Three-level NPC inverter fault diagnosis by the Average Current Park's Vector approach , 2012, 2012 XXth International Conference on Electrical Machines.

[3]  Jiangbiao He,et al.  An on-line diagnostic method for open-circuit switch faults in NPC multilevel converters , 2016, 2016 IEEE Energy Conversion Congress and Exposition (ECCE).

[4]  Lixiang Wei,et al.  Analysis of PWM Frequency Control to Improve the Lifetime of PWM Inverter , 2011, IEEE Transactions on Industry Applications.

[5]  Nabeel A. O. Demerdash,et al.  Diagnosis of open-circuit switch faults in multilevel active-NPC (ANPC) inverters , 2014, 2014 IEEE Transportation Electrification Conference and Expo (ITEC).

[6]  Hirofumi Akagi,et al.  A New Neutral-Point-Clamped PWM Inverter , 1981, IEEE Transactions on Industry Applications.

[7]  M. Bartram,et al.  Doubly-fed-machines in wind-turbine systems: is this application limiting the lifetime of IGBT-frequency-converters? , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[8]  Mohsen Bandar Abadi,et al.  Method to diagnose open-circuit faults in active power switches and clamp-diodes of three-level neutral-point clamped inverters , 2016 .

[9]  Frede Blaabjerg,et al.  Diagnosis and Tolerant Strategy of an Open-Switch Fault for T-Type Three-Level Inverter Systems , 2014, IEEE Transactions on Industry Applications.

[10]  Frede Blaabjerg,et al.  Open-Switch Fault Detection Method of a Back-to-Back Converter Using NPC Topology for Wind Turbine Systems , 2015, IEEE Transactions on Industry Applications.

[11]  F. Blaabjerg,et al.  Method for Detecting an Open-Switch Fault in a Grid-Connected NPC Inverter System , 2012, IEEE Transactions on Power Electronics.

[12]  G. Nicoletti,et al.  Fast power cycling test of IGBT modules in traction application , 1997, Proceedings of Second International Conference on Power Electronics and Drive Systems.

[13]  Dong-Seok Hyun,et al.  Detection Method for Open-Circuit Fault in Neutral-Point-Clamped Inverter Systems , 2009, IEEE Transactions on Industrial Electronics.

[14]  Steffen Bernet,et al.  The active NPC converter and its loss-balancing control , 2005, IEEE Transactions on Industrial Electronics.

[15]  Jiangbiao He,et al.  Health Condition Monitoring and Fault-Tolerant Operation of Adjustable Speed Drives , 2015 .

[16]  Bin Wu,et al.  Powering the Future of Industry: High-Power Adjustable Speed Drive Topologies , 2012, IEEE Industry Applications Magazine.

[17]  Bin Lu,et al.  A Literature Review of IGBT Fault Diagnostic and Protection Methods for Power Inverters , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[18]  Sebastian Liebig,et al.  Efficiency and lifetime of an active power filter with SiC-MOSFETs for aerospace application , 2014 .

[19]  A.M.S. Mendes,et al.  Voltage source inverter fault diagnosis in variable speed AC drives, by the average current Park's vector approach , 1999, IEEE International Electric Machines and Drives Conference. IEMDC'99. Proceedings (Cat. No.99EX272).

[20]  Leon M. Tolbert,et al.  Fault Diagnosis and Reconfiguration for Multilevel Inverter Drive Using AI-Based Techniques , 2007, IEEE Transactions on Industrial Electronics.

[21]  Mohsen Bandar Abadi,et al.  Fault diagnostic algorithm for three-level neutral point clamped AC motor drives, based on the average current Park's vector , 2014 .

[22]  Thomas A. Lipo,et al.  Fast-clamped short-circuit protection of IGBT's , 1999 .