Use of forward projection to correct patient motion during SPECT imaging.

We have developed an iterative method to correct axial and tangential patient motion occurring during tomographic acquisition. The method uses axial images reconstructed from the uncorrected projection images, which are then forward projected to form a basis for registering the original planar images and, in the process, directly seeks to establish a consistent data set. Our method can be applied to all SPECT scans including myocardial and brain SPECT. We demonstrate that the method is capable of detecting and quantitatively correcting for complex motion in both axial and tangential directions. Results from phantom experiments show excellent resolution and contrast recovery after simulated movement in both the axial and tangential directions and initial results with clinical data sets are encouraging.

[1]  J. Cooper,et al.  Effect of patient motion on tomographic myocardial perfusion imaging. , 1992, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  R Noumeir,et al.  Detection of motion during tomographic acquisition by an optical flow algorithm. , 1996, Computers and biomedical research, an international journal.

[3]  E. Botvinick,et al.  A quantitative assessment of patient motion and its effect on myocardial perfusion SPECT images. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  E G DePuey,et al.  How to detect and avoid myocardial perfusion SPECT artifacts. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  D S Berman,et al.  "Upward creep" of the heart: a frequent source of false-positive reversible defects during thallium-201 stress-redistribution SPECT. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  J A Cooper,et al.  Detection of patient motion during tomographic myocardial perfusion imaging. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  D C Barber,et al.  Registration of low resolution medical images. , 1992, Physics in medicine and biology.

[8]  B F Hutton,et al.  Use of 3D reconstruction to correct for patient motion in SPECT. , 1994, Physics in medicine and biology.

[9]  J M Links,et al.  Correction for patient and organ movement in SPECT: application to exercise thallium-201 cardiac imaging. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  H. Liberman,et al.  Use of cross-correlation function to detect patient motion during SPECT imaging. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.