Start-Up Performance Prediction of Line-Fed Solid-Rotor Salient-Pole Synchronous Motors

Solid rotor synchronous motors are widely used in the Oil&Gas industry, because of their mechanical robustness and self-starting capability. The starting performance calculation for these machines is a challenging task. In this paper the specific case of a solid salient pole motor rated 17.5 MW at 1500 rpm is addressed. A simplified but accurate method is proposed and validated experimentally to predict the motor current and torque during direct-on-line (DOL) starting. The proposed methodology combines Finite Element Analysis (FEA) with a lumped-parameter machine model to obtain the best compromise between accuracy and computational efficiency.

[1]  Charles Concordia,et al.  Synchronous machines : theory and performance , 1951 .

[2]  K. J. Binns,et al.  Method for evaluating the starting characteristics of solid salient-pole synchronous motors , 1978 .

[3]  R.C. Schaefer,et al.  Plant Efficiencies Benefit by Selection of Synchronous Motor , 2007, 2007 IEEE Industry Applications Annual Meeting.

[4]  Joo-Hyun Lee,et al.  A starting-up control algorithm of large synchronous generation motor for gas turbosets , 2008, 2008 IEEE International Symposium on Industrial Electronics.

[5]  Shoji Moriyasu,et al.  The Ripple Loss at the Rotor Surface of Synchronous Machines , 1980, IEEE Transactions on Power Apparatus and Systems.

[6]  Jussi Huppunen,et al.  High-Speed Solid-Rotor Induction Machine – Electromagnetic Calculation and Design , 2004 .

[7]  Rakwon Son,et al.  A study for starting characteristic analysis method of salient pole synchronous motors , 2016, 2016 Petroleum and Chemical Industry Technical Conference (PCIC).

[8]  W. Z. Fam Direct Measurement Of The Fundamental And Harmonic Tooth-Ripple Losses In Solid Poles Part I: Theory , 1971 .

[9]  Thomas A. Lipo,et al.  Torsional Coordination of High Speed Synchronous Motors-Part II , 1981, IEEE Transactions on Industry Applications.

[10]  Kurt LeDoux,et al.  Starting large synchronous motors in weak power systems , 2013, Industry Applications Society 60th Annual Petroleum and Chemical Industry Conference.

[11]  R. H. Park,et al.  Two-reaction theory of synchronous machines generalized method of analysis-part I , 1929, Transactions of the American Institute of Electrical Engineers.

[12]  Scott D. Sudhoff,et al.  Magnetizing End-Effects in Salient Pole Machines , 2015, IEEE Transactions on Energy Conversion.

[13]  H. Yamada,et al.  Calculation of Loss in Solid-Salient-Pole Machine , 1984 .

[14]  P. J. Lawrenson,et al.  Tooth-ripple losses in solid poles , 1966 .

[15]  K. Oberretl Eddy Current Losses in Solid Pole Shoes of Synchronous Machines at No-Load and on Load , 1972 .

[16]  T. Fukami,et al.  Measurement of surface losses in solid poles of synchronous machines under load conditions , 2015, 2015 IEEE Magnetics Conference (INTERMAG).

[17]  Ph. Barret Computation of Electromagnetic, Thermal and Mechanical Quantities During Asynchronous Starting up of Solid Salient Pole Synchronous Machines. Experimental Verification , 1981, IEEE Transactions on Power Apparatus and Systems.

[18]  A Tessarolo,et al.  Analytical methods for the accurate computation of stator leakage inductances in multi-phase synchronous machines , 2010, SPEEDAM 2010.

[19]  A Tessarolo,et al.  Design and testing of a 45-MW 100-Hz quadruple-star synchronous motor for a Liquefied Natural Gas turbo-compressor drive , 2010, SPEEDAM 2010.

[20]  W. J. Gibbs Induction and synchronous motors with unlaminated rotors , 1948 .

[21]  H. Yee Effects of finite length in solid-rotor induction machines , 1971 .

[22]  J. C. Das,et al.  Characteristics and analysis of starting of large synchronous motors , 1999, 1999 IEEE Industrial and Commercial Power Systems Technical Conference (Cat. No.99CH36371).