Electrical impedance tomography with an optimized calculable square sensor.

Electrical impedance tomography is a technique that reconstructs the medium distribution in a region of interest through electrical measurements on its boundary. In this paper, an optimized square sensor was designed for electrical impedance tomography in order to obtain maximum information over the cross section of interest, e.g., circulating fluidized beds, in the sense of Shannon information entropy. An analytical model of the sensor was obtained using the conformal transformation. The model indicates that the square sensor possesses calculable property, which allows the calculation of standard values of the sensor directly from a single dimensional measurement that can be made traceable to the SI unit of length. Based on the model, the sensitivity maps and electrical field lines can be calculated in less than a second. Two model based algorithms for image reconstruction, i.e., back projection algorithm based on electrical field lines and iterative Lavrentiev regularization algorithm based on the sensitivity map, were introduced. Simulated results and experimental results validate the feasibility of the algorithms.

[1]  Mi Wang,et al.  Inverse solutions for electrical impedance tomography based on conjugate gradients methods , 2002 .

[2]  Yewang Su,et al.  Investigation of square fluidized beds using capacitance tomography: preliminary results , 2001 .

[3]  Huaxiang Wang,et al.  Electrical impedance tomography with square sensor , 2007 .

[4]  D. Geselowitz An application of electrocardiographic lead theory to impedance plethysmography. , 1971, IEEE transactions on bio-medical engineering.

[5]  Wuqiang Yang,et al.  Electrical capacitance tomography with square sensor , 1999 .

[6]  Trevor York,et al.  Design and application of a multi-modal process tomography system , 2001 .

[7]  A. M. Thompson,et al.  A New Theorem in Electrostatics and its Application to Calculable Standards of Capacitance , 1956, Nature.

[8]  Gu Xingfa,et al.  Iterative Lavrentiev regularization for symmetric kernel-driven operator equations: with application to digital image restoration problems , 2005 .

[9]  J. Lehr,et al.  A vector derivation useful in impedance plethysmographic field calculations. , 1972, IEEE transactions on bio-medical engineering.

[10]  Yong Yan,et al.  A calculable sensor for electrical impedance tomography , 2007 .

[11]  Trevor A. York Status of electrical tomography in industrial applications , 2001, J. Electronic Imaging.

[12]  Anthony J. Peyton,et al.  Chemical engineering applications of electrical process tomography , 2003 .

[13]  W. Zhong,et al.  On precise integration method , 2004 .

[14]  L. Ahlfors Complex Analysis , 1979 .

[15]  B. S. Hoyle,et al.  Engineering and application of a dual-modality process tomography system , 2007 .

[16]  Tomasz Dyakowski,et al.  Applications of electrical tomography for gas-solids and liquid-solids flows : a review , 2000 .

[17]  Claude E. Shannon,et al.  Prediction and Entropy of Printed English , 1951 .

[18]  Radosław Wajman,et al.  Electrical capacitance tomography: image reconstruction along electrical field lines , 2001 .

[19]  Wuqiang Yang,et al.  Tomography for multi-phase flow measurement in the oil industry , 2005 .

[20]  Wuqiang Yang,et al.  Sensitivity distributions of capacitance tomography sensors with parallel field excitation , 1997 .