A “plasmonic cuvette”: dye chemistry coupled to plasmonic interferometry for glucose sensing

Abstract A non-invasive method for the detection of glucose is sought by millions of diabetic patients to improve personal management of blood glucose over a lifetime. In this work, the synergistic advantage of combining plasmonic interferometry with an enzyme-driven dye assay yields an optical sensor capable of detecting glucose in saliva with high sensitivity and selectivity. The sensor, coined a “plasmonic cuvette,” is built around a nano-scale groove-slit-groove (GSG) plasmonic interferometer coupled to an Amplex–red/Glucose–oxidase/Glucose (AR/GOx/Glucose) assay. The proposed device is highly sensitive, with a measured intensity change of 1.7×105%/m (i.e., one order of magnitude more sensitive than without assay) and highly specific for glucose sensing in picoliter volumes, across the physiological range of glucose concentrations found in human saliva (20–240 μm). Real-time glucose monitoring in saliva is achieved by performing a detailed study of the underlying enzyme-driven reactions to determine and tune the effective rate constants in order to reduce the overall assay reaction time to ∼2 min. The results reported suggest that by opportunely choosing the appropriate dye chemistry, a plasmonic cuvette can be turned into a general, real-time sensing scheme for detection of any molecular target, with high sensitivity and selectivity, within extremely low volumes of biological fluid (down to femtoliters). Hereby, we present the results on glucose detection in artificial saliva as a notable and clinically relevant case study.

[1]  S. Schreiber,et al.  Perturbational profiling of a cell-line model of tumorigenesis by using metabolic measurements , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[2]  J. Conway,et al.  A rare isocyanide derived from an unprecedented neutral yttrium(ii) bis(amide) complex , 2023, Chemical science.

[3]  Qinjian Zhao,et al.  Complexities in horseradish peroxidase-catalyzed oxidation of dihydroxyphenoxazine derivatives: appropriate ranges for pH values and hydrogen peroxide concentrations in quantitative analysis. , 2004, Analytical biochemistry.

[4]  R. Gabbay,et al.  Optical coherence tomography-based continuous noninvasive glucose monitoring in patients with diabetes. , 2008, Diabetes technology & therapeutics.

[5]  P. George Chemical Nature of the Secondary Hydrogen Peroxide Compound Formed by Cytochrome-C Peroxidase and Horseradish Peroxidase , 1952, Nature.

[6]  Gearóid MacGearailt,et al.  Fact sheet 3 , 1984 .

[7]  E. Ozbay Plasmonics: Merging Photonics and Electronics at Nanoscale Dimensions , 2006, Science.

[8]  N. Halas,et al.  Nano-optics from sensing to waveguiding , 2007 .

[9]  R. V. Van Duyne,et al.  A comparative analysis of localized and propagating surface plasmon resonance sensors: the binding of concanavalin a to a monosaccharide functionalized self-assembled monolayer. , 2004, Journal of the American Chemical Society.

[10]  B. Brzobohatý,et al.  A new, sensitive method for enzyme kinetic studies of scarce glucosides. , 2006, Journal of biochemical and biophysical methods.

[11]  G. Fasman CRC Handbook of Biochemistry and Molecular Biology , 1975 .

[12]  H. Raether Surface Plasmons on Smooth and Rough Surfaces and on Gratings , 1988 .

[13]  Harel Primack,et al.  Continuous Noninvasive Glucose Monitoring Technology Based on “Occlusion Spectroscopy” , 2007, Journal of diabetes science and technology.

[14]  Kexin Xu,et al.  Chance correlation in non-invasive glucose measurement using near-infrared spectroscopy , 2005 .

[15]  M. Yamaguchi,et al.  Noninvasively measuring blood glucose using saliva. , 1998, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[16]  I. Willner,et al.  Hemin/G-quadruplexes as DNAzymes for the fluorescent detection of DNA, aptamer-thrombin complexes, and probing the activity of glucose oxidase. , 2011, The Analyst.

[17]  W. Edgar,et al.  Saliva: its secretion, composition and functions , 1992, British Dental Journal.

[18]  R. Noble,et al.  The reaction of ferrous horseradish peroxidase with hydrogen peroxide. , 1970, The Journal of biological chemistry.

[19]  Andreas Pfützner,et al.  Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: a European multicenter study with 453 subjects. , 2012, Diabetes technology & therapeutics.

[20]  R. Mason,et al.  Photooxidation of Amplex Red to resorufin: implications of exposing the Amplex Red assay to light. , 2012, Free radical biology & medicine.

[21]  Shih-Ching Wu,et al.  Ion release from NiTi orthodontic wires in artificial saliva with various acidities. , 2003, Biomaterials.

[22]  John Aurie Dean,et al.  Lange's Handbook of Chemistry , 1978 .

[23]  Hans H. Gorris,et al.  Mechanistic aspects of horseradish peroxidase elucidated through single-molecule studies. , 2009, Journal of the American Chemical Society.

[24]  I. Raz,et al.  Noninvasive continuous glucose monitoring using photoacoustic technology-results from the first 62 subjects. , 2007, Diabetes technology & therapeutics.

[25]  L. Vogler Lehninger Principles Of Biochemistry 5th Edition , 2016 .

[26]  H. Lezec,et al.  All-optical modulation by plasmonic excitation of CdSe quantum dots , 2007 .

[27]  N. Keuler,et al.  Factors affecting accuracy and time requirements of a glucose oxidase-peroxidase assay for determination of glucose. , 2009, Journal of AOAC International.

[28]  J. B. Pitner,et al.  Direct detection of glucose by surface plasmon resonance with bacterial glucose/galactose-binding protein. , 2004, Biosensors & bioelectronics.

[29]  R. V. Van Duyne,et al.  A nanoscale optical biosensor: sensitivity and selectivity of an approach based on the localized surface plasmon resonance spectroscopy of triangular silver nanoparticles. , 2002, Journal of the American Chemical Society.

[30]  Alexandre G. Brolo,et al.  Plasmonics for future biosensors , 2012, Nature Photonics.

[31]  Joseph Wang,et al.  Electrochemical Glucose Biosensors , 2008 .

[32]  Kevin H. Hazen,et al.  Comparison of glucose concentration in interstitial fluid, and capillary and venous blood during rapid changes in blood glucose levels. , 2001, Diabetes technology & therapeutics.

[33]  S. Bertolotti,et al.  The Excited-State Interaction of Resazurin and Resorufin with Aminesin Aqueous Solutions. Photophysics and Photochemical Reaction¶ , 2002, Photochemistry and Photobiology.

[34]  R. Thibert,et al.  Fluorometric determination of hydrogen peroxide using resorufin and peroxidase , 1988 .

[35]  Olga Lyandres,et al.  Progress toward an in vivo surface-enhanced Raman spectroscopy glucose sensor. , 2008, Diabetes technology & therapeutics.

[36]  Jeffrey D Zahn,et al.  Noninvasive Glucose Monitoring: A Novel Approach , 2009, Journal of diabetes science and technology.

[37]  A. Panchbhai,et al.  Correlation of Salivary Glucose Level with Blood Glucose Level in Diabetes Mellitus , 2012, Journal of oral & maxillofacial research.

[38]  K. Uchiyama,et al.  Photochemical immobilization of protein on the inner wall of a microchannel and Its application in a glucose sensor , 2006 .

[39]  P. Bohn,et al.  Enzymatic activity of surface-immobilized horseradish peroxidase confined to micrometer- to nanometer-scale structures in nanocapillary array membranes. , 2009, The Analyst.

[40]  Domenico Pacifici,et al.  Nanoscale plasmonic interferometers for multispectral, high-throughput biochemical sensing. , 2012, Nano letters.

[41]  Yuan-Ting Zhang,et al.  A surface plasmon resonance system for the measurement of glucose in aqueous solution , 2005 .

[42]  R. Haugland,et al.  A stable nonfluorescent derivative of resorufin for the fluorometric determination of trace hydrogen peroxide: applications in detecting the activity of phagocyte NADPH oxidase and other oxidases. , 1997, Analytical biochemistry.

[43]  B. Cameron,et al.  Noninvasive Polarimetric-Based Glucose Monitoring: An in Vivo Study , 2011, Journal of diabetes science and technology.

[44]  Abdullah Sener,et al.  Salivary Glucose Concentration and Excretion in Normal and Diabetic Subjects , 2009, Journal of biomedicine & biotechnology.

[45]  Jeff Bernhardt,et al.  Requirements for Calibration in Noninvasive Glucose Monitoring by Raman Spectroscopy , 2009, Journal of diabetes science and technology.

[46]  Richard Barnett Diabetes , 1904, The Lancet.

[47]  J. Homola Surface plasmon resonance sensors for detection of chemical and biological species. , 2008, Chemical reviews.