A formaldehyde trace gas sensor based on a thermoelectrically cooled CW-DFB quantum cascade laser

We report the development of a trace gas sensor for the detection of atmospheric formaldehyde utilizing a thermoelectrically cooled distributed-feedback quantum cascade laser operating in continuous-wave mode at 5.68 μm. Wavelength modulation spectroscopy was combined with second harmonic detection and zero air based background subtraction techniques to enhance both detection sensitivity and precision to ∼2.5 ppbv for H2CO measurement with an integration time of less than 1 second and a 36 m optical path length. A novel analysis technique based on wavelet transform for noise reduction was successfully applied to improve the sensor performance, yielding sub-ppb measurement precision without reducing the fast temporal response.

[1]  B. Heikes,et al.  Intercomparison of six ambient [CH2O] measurement techniques , 1997 .

[2]  J. Lelieveld,et al.  QUALITAS: A mid-infrared spectrometer for sensitive trace gas measurements based on quantum cascade lasers in CW operation , 2005 .

[3]  A. Fried,et al.  Evaluation of inlets used for the airborne measurement of formaldehyde , 2002 .

[4]  V. Wagner,et al.  Formaldehyde measurements in the marine boundary layer of the Indian Ocean during the 1999 INDOEX cruise of the RV Ronald H. Brown , 2001 .

[5]  Jingsong Li,et al.  Applications of wavelet transform to quantum cascade laser spectrometer for atmospheric trace gas measurements , 2012 .

[6]  A. Cho,et al.  Sensitive absorption spectroscopy with a room-temperature distributed-feedback quantum-cascade laser. , 1998, Optics letters.

[7]  M. Carras,et al.  Optical-feedback cavity-enhanced absorption spectroscopy with a quantum-cascade laser yields the lowest formaldehyde detection limit , 2013, Applied Physics B.

[8]  D. R. Lawson,et al.  Formaldehyde Measurement Methods Evaluation and Ambient Concentrations During the Carbonaceous Species Methods Comparison Study , 1990 .

[9]  Frank G. Wienhold,et al.  Compact multilaser TDLAS for trace gas flux measurements based on a micrometeorological technique , 1999, Optics & Photonics.

[10]  P. Werle,et al.  Signal processing and calibration procedures for in situ diode-laser absorption spectroscopy. , 2004, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[11]  J. Lelieveld,et al.  Applications of quantum cascade lasers for sensitive trace gas measurements of CO, CH4, N2O and HCHO , 2008 .

[12]  P. Werle,et al.  The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS) , 1993 .

[13]  M. Fraser,et al.  Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN , 2001, Applied physics. B, Lasers and optics.

[14]  J. Drummond,et al.  Laboratory, ground-based, and airborne tunable diode laser systems: performance characteristics and applications in atmospheric studies , 1998 .

[15]  Anthony O'Keefe,et al.  Cavity-enhanced quantum-cascade laser-based instrument for carbon monoxide measurements. , 2005, Applied optics.

[16]  In-flight measurements of ambient methane, nitrous oxide and water using a quantum cascade laser based spectrometer , 2008 .

[17]  F. Capasso,et al.  Quantum-cascade laser measurements of stratospheric methane and nitrous oxide. , 2001, Applied optics.

[18]  J G Anderson,et al.  A new cavity based absorption instrument for detection of water isotopologues in the upper troposphere and lower stratosphere. , 2009, The Review of scientific instruments.

[19]  N. Langford,et al.  A compact quantum-cascade laser based spectrometer for monitoring the concentrations of methane and nitrous oxide in the troposphere , 2006 .

[20]  M. Angelmahr,et al.  Photoacoustic spectroscopy of formaldehyde with tunable laser radiation at the parts per billion level , 2006 .

[21]  P. Hering,et al.  Rapid formaldehyde monitoring in ambient air by means of mid-infrared cavity leak-out spectroscopy , 2002 .

[22]  Harold I. Schiff,et al.  Measurements of formaldehyde in the troposphere by tunable diode laser absorption spectroscopy , 1989 .

[23]  David D. Nelson,et al.  Comparison of cw and pulsed operation with a TE-cooled quantum cascade infrared laser for detection of nitric oxide at 1900 cm-1 , 2006 .

[24]  R. Königstedt,et al.  Real-Time Measurements of Atmospheric CO Using a Continuous-Wave Room Temperature Quantum Cascade Laser Spectrometer , 2012, 2012 Symposium on Photonics and Optoelectronics.

[25]  Vincenzo Spagnolo,et al.  Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas , 2009, Sensors.