CFD Analysis on the Thermal Hydraulic Performance of an SAH Duct with Multi V-Shape Roughened Ribs

This study presents the heat transfer and fluid flow characteristics in a rib-roughened SAH (solar air heater) channel. The artificial roughness of the rectangular channel was in the form of a thin circular wire in discrete multi V-pattern rib geometries. The effect of this geometry on heat transfer, fluid flow, and performance augmentation was investigated using the CFD (computational fluid dynamics). The roughness parameters were a relative discrete distance of 0.69, a relative rib height of 0.043, a relative rib pitch of 10, a relative rib width of 6.0, and a flow-attack-angle of 60°. The discrete width ratios and Reynolds numbers ranged from 0.5 to 2.0 and from 2000 to 20,000, respectively. The CFD results using the renormalization k-epsilon model were in good agreement with the empirical relationship. This model was used to investigate the heat transfer and fluid flow characteristics in the multi V-pattern rib roughened SAH channel. The thermo-hydraulic performance was found to be the best for the discrete width ratio of 1.0. A discrete multi V-pattern rib combined with dimple staggered ribs also had better overall thermal performance compared to other rib shapes.

[1]  Angelika Bayer,et al.  Solar Engineering Of Thermal Processes , 2016 .

[2]  Anil Kumar,et al.  Thermohydraulic performance of rectangular ducts with different multiple V-rib roughness shapes: A comprehensive review and comparative study , 2016 .

[3]  C. P. Lee,et al.  Augmented Heat Transfer in Square Channels With Parallel, Crossed, and V-Shaped Angled Ribs , 1991 .

[4]  R. T. Kukreja,et al.  Local heat/mass transfer distribution in a square channel with full and V-shaped ribs , 1993 .

[5]  A. N. Tikekar,et al.  Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFD , 2010 .

[6]  V. S. Hans,et al.  CFD (computational fluid dynamics) investigation on Nusselt number and friction factor of solar air heater duct roughened with non-uniform cross-section transverse rib , 2015 .

[7]  R. Saini,et al.  Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having arc-shaped wire as artificial roughness , 2008 .

[8]  Vipul Pratik Thakre,et al.  Review on “Thermo hydraulic Performance of Artificially Roughened Solar Air Heater , 2018 .

[9]  A. K. M. Sadrul Islam,et al.  Plate Fin and Tube Heat Exchanger Modeling: Effects of Performance Parameters for Turbulent Flow Regime , 2014 .

[10]  Rajesh Maithani,et al.  Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with V-ribs with symmetrical gaps , 2016 .

[11]  M. Taslim,et al.  EXPERIMENTAL HEAT TRANSFER AND FRICTION IN CHANNELS ROUGHENED WITH ANGLED, V-SHAPED AND DISCRETE RIBS ON TWO OPPOSITE WALLS , 1994 .

[12]  Bengt Sundén,et al.  AN EXPERIMENTAL INVESTIGATION OF HEAT TRANSFER AND FLUID FLOW IN A RECTANGULAR DUCT WITH BROKEN V-SHAPED RIBS , 2004 .

[13]  Man-Hoe Kim,et al.  Convective heat transfer enhancement in solar air channels , 2015 .

[14]  R. Saini,et al.  CFD based performance analysis of a solar air heater duct provided with artificial roughness , 2009 .

[15]  V. S. Hans,et al.  Heat transfer and friction factor correlations for a solar air heater duct roughened artificially with multiple v-ribs , 2010 .

[16]  Anil Kumar,et al.  Effect of roughness width ratios in discrete multi V-rib with staggered rib roughness on overall thermal performance of solar air channel , 2015 .

[17]  R. Karwa EXPERIMENTAL STUDIES OF AUGMENTED HEAT TRANSFER AND FRICTION IN ASYMMETRICALLY HEATED RECTANGULAR DUCTS WITH RIBS ON THE HEATED WALL IN TRANSVERSE, INCLINED, V-CONTINUOUS AND V-DISCRETE PATTERN , 2003 .

[18]  Anil Kumar,et al.  Heat and fluid flow characteristics of roughened solar air heater ducts – A review , 2012 .

[19]  R. Saini,et al.  Development of correlations for Nusselt number and friction factor for solar air heater with roughened duct having multi v-shaped with gap rib as artificial roughness , 2013 .

[20]  Je-Chin Han,et al.  Thermal Performance of Angled, V-Shaped, and W-Shaped Rib Turbulators in Rotating Rectangular Cooling Channels (AR=4:1) , 2004 .

[21]  Brij M. Bhushan,et al.  Nusselt number and friction factor correlations for solar air heater duct having artificially roughened absorber plate , 2011 .

[22]  B. N. Prasad,et al.  Effect of artificial roughness on heat transfer and friction factor in a solar air heater , 1988 .

[23]  M. Taslim,et al.  Darryl E. Metzger Memorial Session Paper: Experimental Heat Transfer and Friction in Channels Roughened With Angled, V-Shaped, and Discrete Ribs on Two Opposite Walls , 1996 .

[24]  J. L. Bhagoria,et al.  A CFD (computational fluid dynamics) based heat transfer and fluid flow analysis of a solar air heater provided with circular transverse wire rib roughness on the absorber plate , 2013 .

[25]  Anil Kumar,et al.  Numerical optimization of solar air heaters having different types of roughness shapes on the heated plate – Technical note , 2014 .

[26]  Anil Kumar,et al.  A review of thermohydraulic performance of artificially roughened solar air heaters , 2014 .

[27]  S. C. Solanki,et al.  Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater , 2006 .

[28]  Anil Kumar,et al.  Heat transfer and fluid flow characteristics in air duct with various V-pattern rib roughness on the heated plate: A comparative study , 2016 .

[29]  S. Mullick,et al.  Heat transfer characteristics of a solar air heater used for drying purposes , 1983 .