A smartphone-enabled wireless and batteryless implantable blood flow sensor for remote monitoring of prosthetic heart valve function

Aortic valve disease is one of the leading forms of complications in the cardiovascular system. The failing native aortic valve is routinely surgically replaced with a bioprosthesis. However, insufficient durability of bioprosthetic heart valves often requires reintervention. Valve degradation can be assessed by an analysis of the blood flow characteristics downstream of the valve. This is cost and labor intensive using clinical methodologies and is performed infrequently. The integration of consumer smartphones and implantable blood flow sensors into the data acquisition chain facilitates remote management of patients that is not limited by access to clinical facilities. This article describes the characteristics of an implantable magnetic blood flow sensor which was optimized for small size and low power consumption to allow for batteryless operation. The data is wirelessly transmitted to the patient’s smartphone for in-depth processing. Tests using three different experimental setups confirmed that wireless and batteryless blood flow recording using a magnetic flow meter technique is feasible and that the sensor system is capable of monitoring the characteristic flow downstream of the valve.

[1]  C. Mills Chapter 3 – Measurement of Pulsatile Flow and Flow Velocity , 1972 .

[2]  Kath Bogie,et al.  Vascular Graft Pressure-Flow Monitoring Using 3D Printed MWCNT-PDMS Strain Sensors , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  Helmut Soltner,et al.  A portable Halbach magnet that can be opened and closed without force: the NMR-CUFF. , 2011, Journal of magnetic resonance.

[4]  Mevlüt Çelik,et al.  Mechanical versus bioprosthetic aortic valve replacement , 2017, European heart journal.

[5]  A Starr,et al.  Actuarial versus actual risk of porcine structural valve deterioration. , 1994, The Journal of thoracic and cardiovascular surgery.

[6]  T. Rösgen,et al.  Leaflet Kinematics of Mechanical and Bioprosthetic Aortic Valve Prostheses , 2017, ASAIO journal.

[7]  H. P. Schwan,et al.  Electrical properties of blood and its constitutents: Alternating current spectroscopy , 1983, Blut: Zeitschrift für die Gesamte Blutforschung.

[8]  Hao-Chung Yang,et al.  Development of a Flexible Implantable Sensor for Postoperative Monitoring of Blood Flow , 2012, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[9]  Hans-Peter Raich,et al.  Design and construction of a dipolar Halbach array with a homogeneous field from identical bar magnets: NMR Mandhalas , 2004 .

[10]  E. Epstein,et al.  Aortic valve disease. , 1979, British journal of hospital medicine.

[11]  Zhenan Bao,et al.  Biodegradable and flexible arterial-pulse sensor for the wireless monitoring of blood flow , 2019, Nature Biomedical Engineering.

[12]  David Vilkomerson,et al.  Implantable ultrasound devices , 2008, SPIE Medical Imaging.

[13]  Dominik Obrist,et al.  Automated diagnosis of heart valve degradation using novelty detection algorithms and machine learning , 2019, PloS one.

[14]  Marlin H. Mickle,et al.  Entirely Implanted Wireless Doppler Sensor for Monitoring Venous Flow , 2014 .

[15]  Bernhard Vennemann Wireless Blood Flow Sensing for Automated Diagnostics , 2019 .

[16]  Marlin H. Mickle,et al.  A System for Simple Real-Time Anastomotic Failure Detection and Wireless Blood Flow Monitoring in the Lower Limbs , 2016, IEEE Journal of Translational Engineering in Health and Medicine.

[17]  J. Mallinson One-sided fluxes -- A magnetic curiosity? , 1973 .

[18]  D. Vilkomerson,et al.  Implantable Doppler system for self-monitoring vascular grafts , 2004, IEEE Ultrasonics Symposium, 2004.

[19]  J. A. Shercliff The theory of electromagnetic flow-measurement , 1962 .

[20]  Jia Hao Cheong,et al.  Ultra-low-power wireless implantable blood flow sensing microsystem for vascular graft applications , 2011, 2011 International Symposium on Integrated Circuits.

[21]  Y. L. Young,et al.  Membrane thickness design of implantable bio-MEMS sensors for the in-situ monitoring of blood flow , 2007, Journal of materials science. Materials in medicine.

[22]  E. Furlani Permanent Magnet and Electromechanical Devices: Materials, Analysis, and Applications , 2001 .

[23]  T.J. Gale,et al.  Development of an implantable blood flow and pressure monitor for pulmonary hypertension , 2004, Computers in Cardiology, 2004.

[24]  K. Halbach Design of permanent multipole magnets with oriented rare earth cobalt material , 1980 .

[25]  Ervin Sejdic,et al.  The Development of a Wireless Implantable Blood Flow Monitor , 2015, Plastic and reconstructive surgery.

[26]  I Vesely,et al.  The evolution of bioprosthetic heart valve design and its impact on durability. , 2003, Cardiovascular pathology : the official journal of the Society for Cardiovascular Pathology.

[27]  Xin Liu,et al.  An Inductively Powered Implantable Blood Flow Sensor Microsystem for Vascular Grafts , 2012, IEEE Transactions on Biomedical Engineering.

[28]  J. Woodcock Theory and Practice of Blood Flow Measurement , 1975 .

[29]  Sai Chun Tang,et al.  Magnetically-powered implantable Doppler blood flow meter , 2014, 2014 IEEE International Ultrasonics Symposium.