Monitoring of Aluminum in Whole Blood, Plasma, Serum, and Water by a Single Procedure Using Flameless Atomic Absorption Spectrophotometry

: A simple, time-saving procedure to measure aluminum (AI) in whole blood, plasma, and water samples of low ionic strength by flameless atomic absorption spectrometry is presented. With this procedure, an analagous pretreatment is given to all samples. Moreover, the pretreated samples are analyzed using an identical program of the atomic absorption spectrophotometer. The detection limit is 1.3 micrograms/L for aqueous solutions and 1.9 micrograms/L, 1.8 micrograms/L, and 2.3 microL for serum, plasma, and blood samples respectively. The precision of the method varies between 2.8% and 4.2% of all analyses. Using this method, a comparison was made between Al levels in whole blood (AlB) and plasma (AlP) in rats and AlB and AlP in renal patients. The AlB and AlP were strongly correlated. It is concluded that the monitoring of AlB may have a similar prognostic value for toxicity as the monitoring of AlP, but more experimental advantages.

[1]  D. Fa Toxicological aspects of aluminum poisoning in clinical nephrology. , 1985 .

[2]  J. Savory,et al.  ALUMINIUM POISONING: DIALYSIS ENCEPHALOPATHY, OSTEOMALACIA, AND ANAEMIA , 1983, The Lancet.

[3]  R. Bertholf,et al.  Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry. , 1983, Clinical chemistry.

[4]  D. Kerr,et al.  A method for the routine determination of aluminium in serum and water by flameless atomic absorption spectrometry. , 1982, Clinica chimica acta; international journal of clinical chemistry.

[5]  A. Henderson,et al.  Improved determination of aluminum in serum and urine with use of a stabilized temperature platform furnace. , 1982, Clinical chemistry.

[6]  R. Yokel Hair as an indicator of excessive aluminum exposure. , 1982, Clinical chemistry.

[7]  G. Fell,et al.  Determination of aluminium in blood plasma or serum by electrothermal atomic absorption spectrometry , 1981 .

[8]  J. Savory,et al.  Electrothermal atomic absorption spectrometric determination of aluminum in blood serum , 1981 .

[9]  J. Gorsky,et al.  Determination of aluminum in biological samples by atomic absorption spectrophotometry with a graphite furnace. , 1978, Clinical chemistry.

[10]  F. J. Langmyhr,et al.  Atomic absorption spectrometric determination of aluminium in whole blood. , 1977, Analytica chimica acta.

[11]  J. Flendrig,et al.  ALUMINIUM AND DIALYSIS DEMENTIA , 1976, The Lancet.

[12]  W. D. Kaehny,et al.  The dialysis encephalopathy syndrome. Possible aluminum intoxication. , 1976, The New England journal of medicine.