A Stray Magnetic Flux-Based Robust Diagnosis Method for Detection and Location of Interturn Short Circuit Fault in PMSM

Early diagnosis of interturn short circuit (ITSC) fault is essential to prevent catastrophic electrical machine failures. Along with the detection, locating the faulty winding at its incipient stage is also critical to reduce the outage duration and operation losses. This article proposes a practical method to detect the ITSC fault and locate the faulty winding in permanent magnet synchronous motors (PMSMs) through stray magnetic flux monitoring. It is shown that relying on the fundamental stray flux component can potentially underperform at certain operating conditions leading to fault negative error. To compensate this shortcoming, the third harmonic component of stray flux is comprehensively analyzed and proposed as a complementary ITSC fault indicator. Furthermore, its reliability over the wide range of motor operation is verified to eliminate potential fault negative errors. It is also shown that the proposed method is independent of the fault severity which is a major advantage for practical applications. The findings are supported through 2-D-FEA PMSM drive system simulations and experiments under two different fault severity cases.

[1]  Yuan Qi,et al.  A Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults , 2018, IEEE Transactions on Power Electronics.

[2]  Ali Emadi,et al.  Making the Case for Electrified Transportation , 2015, IEEE Transactions on Transportation Electrification.

[3]  A.H. Bonnett,et al.  Increased Efficiency Versus Increased Reliability , 2008, IEEE Industry Applications Magazine.

[4]  H.A. Toliyat,et al.  Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review , 2005, IEEE Transactions on Energy Conversion.

[5]  W.G. Zanardelli,et al.  Identification of Intermittent Electrical and Mechanical Faults in Permanent-Magnet AC Drives Based on Time–Frequency Analysis , 2007, IEEE Transactions on Industry Applications.

[6]  H. Henao,et al.  A frequency-domain detection of stator winding faults in induction machines using an external flux sensor , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).

[7]  Osama Mohammed,et al.  Stator Fault Detection on DTC-Driven IM via Magnetic Signatures Aided by 2-D FEA Co-Simulation , 2019, IEEE Transactions on Magnetics.

[8]  Kyeong-Hwa Kim,et al.  Online fault-detecting scheme of an inverter-fed permanent magnet synchronous motor under stator winding shorted turn and inverter switch open , 2011 .

[9]  W. T. Thomson,et al.  Current signature analysis to detect induction motor faults , 2001 .

[10]  Richard J. Povinelli,et al.  Induction Machine Broken Bar and Stator Short-Circuit Fault Diagnostics Based on Three-Phase Stator Current Envelopes , 2008, IEEE Transactions on Industrial Electronics.

[11]  Luis Romeral,et al.  Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition , 2008, IEEE Transactions on Industrial Electronics.

[12]  Libing Cao,et al.  Inter-Turn Short-Circuit Fault Detection Approach for Permanent Magnet Synchronous Machines Through Stray Magnetic Field Sensing , 2019, IEEE Sensors Journal.

[13]  G.C. Soukup,et al.  Cause and analysis of stator and rotor failures in 3-phase squirrel cage induction motors , 1991, Conference Record of 1991 Annual Pulp and Paper Industry Technical Conference.

[14]  Yuan Qi,et al.  Interturn Short-Circuit Faults in Permanent Magnet Synchronous Machines: An Extended Review and Comprehensive Analysis , 2018, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[15]  M. Dalva,et al.  A survey of faults on induction motors in offshore oil industry, petrochemical industry, gas terminals and oil refineries , 1994, Proceedings of IEEE Petroleum and Chemical Industry Technical Conference (PCIC '94).

[16]  Bilal Akin,et al.  Broken rotor bar fault monitoring based on fluxgate sensor measurement of leakage flux , 2017, 2017 IEEE International Electric Machines and Drives Conference (IEMDC).

[17]  C. Gerada,et al.  The results do mesh , 2007, IEEE Industry Applications Magazine.

[18]  Qing Wu,et al.  Fast Single-Turn Sensitive Stator Inter-Turn Fault Detection of Induction Machines Based on Positive and Negative Sequence Third Harmonic Components of Line Currents , 2008, 2008 IEEE Industry Applications Society Annual Meeting.

[19]  Thomas G. Habetler,et al.  A Survey on Testing and Monitoring Methods for Stator Insulation Systems of Low-Voltage Induction Machines Focusing on Turn Insulation Problems , 2008, IEEE Transactions on Industrial Electronics.

[20]  J. Cusido,et al.  Fault detection by means of Hilbert Huang Transform of the stator current in a PMSM with demagnetization , 2010, 2007 IEEE International Symposium on Intelligent Signal Processing.

[21]  R. Romary,et al.  Non-Invasive Detection of Rotor Short-Circuit Fault in Synchronous Machines by Analysis of Stray Magnetic Field and Frame Vibrations , 2016, IEEE Transactions on Magnetics.

[22]  J. Penman,et al.  Detection and location of interturn short circuits in the stator windings of operating motors , 1994 .