Open ISEmeter: An open hardware high-impedance interface for potentiometric detection.

In this work, a new open hardware interface based on Arduino to read electromotive force (emf) from potentiometric detectors is presented. The interface has been fully designed with the open code philosophy and all documentation will be accessible on web. The paper describes a comprehensive project including the electronic design, the firmware loaded on Arduino, and the Java-coded graphical user interface to load data in a computer (PC or Mac) for processing. The prototype was tested by measuring the calibration curve of a detector. As detection element, an active poly(vinyl chloride)-based membrane was used, doped with cetyltrimethylammonium dodecylsulphate (CTA(+)-DS(-)). The experimental measures of emf indicate Nernstian behaviour with the CTA(+) content of test solutions, as it was described in the literature, proving the validity of the developed prototype. A comparative analysis of performance was made by using the same chemical detector but changing the measurement instrumentation.

[1]  J. Ortuño,et al.  Flow-injection potentiometric determination of triiodide by plasticized poly(vinyl chloride) membrane electrodes and its application to the determination of chlorine-containing disinfectants. , 2005, Talanta.

[2]  K. Hayakawa,et al.  Surfactant-polyelectrolyte interactions. 1. Binding of dodecyltrimethylammonium ions by sodium dextransulfate and sodium poly(styrenesulfonate) in aqueous solution in the presence of sodium chloride , 1982 .

[3]  S. Meghdadi,et al.  Cadmium Selective PVC-Membranes Sensor Based on 1, 2-Bis (Quinoline-2-Carboxamido) -4-Chlorobenzene as a Neutral Carrier , 2008, IEEE Sensors Journal.

[4]  João Rodrigo Santos,et al.  Development of a tubular fluoride potentiometric detector for flow analysis: evaluation and analytical applications. , 2007, Analytica chimica acta.

[5]  H. Kahlert,et al.  Determination of the titratable acidity and the pH of wine based on potentiometric flow injection analysis. , 2013, Talanta.

[6]  A. Arenas,et al.  Inexpensive device for measurements with ion-selective and pH electrodes , 1990 .

[7]  Osman Çubuk,et al.  PVC-Membrane Potentiometric Sensor for the Determination of Tamoxifen in Pharmaceutical Formulations , 2015, IEEE Sensors Journal.

[8]  V. L. Silva,et al.  Sequential Injection Lab-on-Valve Procedure for the Determination of Amantadine Using Potentiometric Methods , 2007 .

[9]  Jan Šlégr,et al.  ChemDuino: Adapting Arduino for Low-Cost Chemical Measurements in Lecture and Laboratory , 2015 .

[10]  S. Hassan,et al.  Novel miniaturized sensors for potentiometric batch and flow-injection analysis (FIA) of perchlorate in fireworks and propellants. , 2014, Talanta.

[11]  M. Andaç,et al.  Application of a New pH-Sensitive Electrode as a Detector in Flow Injection Potentiometry , 2005 .

[12]  R. Koncki,et al.  Thick-film potentiometric biosensor for bloodless monitoring of hemodialysis , 2006 .

[13]  I. Badr,et al.  New Potentiometric Sensors for Picrate Determination Using Flow‐Through System: Application to Kinetic Assessment of Se(IV) , 2013 .

[14]  K. Gupta,et al.  Lead (II) ion selective electrodes based on diphenylmethyl-N-phenylhydroxamic acid ionophore in cyanocopolymer matrix , 2001 .

[15]  E. Richter,et al.  FIA-potentiometry in the sub-Nernstian response region for rapid and direct chloride assays in milk and in coconut water. , 2005, Talanta.

[16]  A. Das,et al.  A Potentiometric Sensor System with Integrated Circuitry for in situ Environmental Monitoring , 2006, 2006 Sixth IEEE Conference on Nanotechnology.

[17]  S. Lunsford,et al.  Detection of Catechol by Potentiometric-Flow Injection Analysis in the Presence of Interferents , 2007 .

[18]  Robert Koncki,et al.  Flow injection system for potentiometric determination of alkaline phosphatase inhibitors. , 2006, Analytica chimica acta.

[19]  A. Allafchian,et al.  Highly Selective Potentiometric Membrane Sensor for Hg(II) Based on Bis(Benzoyl Acetone) Diethylene Triamine , 2008, IEEE Sensors Journal.

[20]  Ofloxacin determination in urine, serum and pharmaceuticals using an automatic flow potentiometric system. , 2013, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[21]  Aaron R Wheeler,et al.  DStat: A Versatile, Open-Source Potentiostat for Electroanalysis and Integration , 2015, PloS one.