Effect of gravity framing on the overstrength and collapse capacity of steel frame buildings with perimeter special moment frames

This paper investigates the effect of the gravity framing system on the overstrength and collapse risk of steel frame buildings with perimeter special moment frames (SMFs) designed in North America. A nonlinear analytical model that simulates the pinched hysteretic response of typical shear tab connections is calibrated with past experimental data. The proposed modeling approach is implemented into nonlinear analytical models of archetype steel buildings with different heights. It is found that when the gravity framing is considered as part of the analytical model, the overall base shear strength of steel frame buildings with perimeter SMFs could be 50% larger than that of the bare SMFs. This is attributed to the gravity framing as well as the composite action provided by the concrete slab. The same analytical models (i) achieve a static overstrength factor, Ωs larger than 3.0 and (ii) pass the collapse risk evaluation criteria by FEMA P695 regardless of the assigned total system uncertainty. However, when more precise collapse metrics are considered for collapse risk assessment of steel frame buildings with perimeter SMFs, a tolerable probability of collapse is only achieved in a return period of 50years when the perimeter SMFs of mid-rise steel buildings are designed with a strong-column/weak-beam ratio larger than 1.5. The concept of the dynamic overstrength, Ωd is introduced that captures the inelastic force redistribution due to dynamic loading. Steel frame buildings with perimeter SMFs achieve a Ωd>3 regardless if the gravity framing is considered as part of the nonlinear analytical model representation. © 2014 John Wiley & Sons, Ltd.

[1]  Dimitrios G. Lignos,et al.  Collapse Assessment of Steel Moment Frames Based on E-Defense Full-Scale Shake Table Collapse Tests , 2013 .

[2]  Ronald O. Hamburger,et al.  Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, ANSI/AISC 358-05 , 2006 .

[3]  Francisco X. Flores,et al.  Influence of the gravity framing system on the collapse performance of special steel moment frames , 2014 .

[4]  Thambirajah Balendra,et al.  Overstrength and Ductility Factors for Steel Frames Designed According to BS 5950 , 2003 .

[5]  Dimitrios G. Lignos,et al.  Computational Approach for Collapse Assessment of Concentrically Braced Frames in Seismic Regions , 2014 .

[6]  L. Lowes,et al.  A Beam-Column Joint Model for Simulating the Earthquake Response of Reinforced Concrete Frames , 2004 .

[7]  Masayoshi Nakashima,et al.  Effect of gravity columns on mitigation of drift concentration for braced frames , 2009 .

[8]  Sherif El-Tawil,et al.  Seismic performance of steel frames with reduced beam section connections , 2005 .

[9]  Roberto T. Leon,et al.  BIDIRECTIONAL TESTS ON PARTIALLY RESTRAINED, COMPOSITE BEAM-TO-COLUMN CONNECTIONS , 2004 .

[10]  Gregory L. Fenves,et al.  Object-oriented finite element programming: frameworks for analysis, algorithms and parallel computing , 1997 .

[11]  Farzin Zareian,et al.  Evaluation of Seismic Collapse Performance of Steel Special Moment Resisting Frames Using FEMA P695 (ATC-63) Methodology , 2010 .

[12]  Anil K. Chopra,et al.  Role of Higher-“Mode” Pushover Analyses in Seismic Analysis of Buildings , 2005 .

[13]  Dimitrios G. Lignos,et al.  An efficient method for estimating the collapse risk of structures in seismic regions , 2013 .

[14]  Babak Alavi,et al.  Behavior of moment‐resisting frame structures subjected to near‐fault ground motions , 2004 .

[15]  Roberto T. Leon,et al.  Seismic Response of Composite Moment-Resisting Connections. I: Performance , 1998 .

[16]  L. Ibarra Global collapse of frame structures under seismic excitations , 2003 .

[17]  Dimitrios Vamvatsikos,et al.  Incremental dynamic analysis , 2002 .

[18]  James O. Malley,et al.  ATC-72 of the PEER Tall Buildings Initiative: Interim Guidelines on Modeling and Acceptance Criteria for Seismic Design and Analysis of Tall Buildings , 2008 .

[19]  Douglas A. Foutch,et al.  Modeling of steel moment frames for seismic loads , 2002 .

[20]  Andrew S. Whittaker,et al.  SEISMIC RESPONSE MODIFICATION FACTORS , 1999 .

[21]  H. Krawinkler SHAKING TABLE COLLAPSE TESTS OF TWO SCALE MODELS OF A 4-STORY MOMENT RESISTING STEEL FRAME , 2008 .

[22]  R. Medina,et al.  A practical method for proper modeling of structural damping in inelastic plane structural systems , 2010 .

[23]  Dimitrios G. Lignos,et al.  Seismic Assessment of Steel Moment Frames Using Simplified Nonlinear Models , 2013 .

[24]  Farzin Zareian,et al.  Seismic Evaluation of Steel Moment Frames and Shear Walls Using Nonlinear Static Analysis Procedures , 2011 .

[25]  H Krawinkler,et al.  Shear in Beam-Column Joints in Seismic Design of Steel Frames , 1978, Engineering Journal.

[26]  Farzin Zareian,et al.  Assessment of probability of collapse and design for collapse safety , 2007 .

[27]  Satoshi Yamada,et al.  Full scale shaking table collapse experiment on 4-story steel moment frame: Part 2 detail of collapse behavior , 2009 .

[28]  Maikol Del Carpio Ramos Hybrid simulation of the seismic response of a steel moment frame building structure through collapse , 2013 .

[29]  Dimitrios G. Lignos,et al.  Modeling of the composite action in fully restrained beam‐to‐column connections: implications in the seismic design and collapse capacity of steel special moment frames , 2014 .

[30]  Helmut Krawinkler,et al.  Deterioration Modeling of Steel Components in Support of Collapse Prediction of Steel Moment Frames under Earthquake Loading , 2011 .

[31]  Craig D. Comartin,et al.  Applicability of Nonlinear Multiple-Degree-of-Freedom Modeling for Design | NIST , 2010 .

[32]  Judy Liu,et al.  Cyclic Testing of Simple Connections Including Effects of Slab , 2000 .

[33]  Gregory G. Deierlein,et al.  Seismic Design of Composite Moment Frame Buildings—Case Studies and Codes Implications , 2002 .

[34]  Sudhir K. Jain,et al.  Seismic Overstrength in Reinforced Concrete Frames , 1995 .

[35]  Dimitrios G. Lignos,et al.  Numerical and experimental evaluation of seismic capacity of high-rise steel buildings subjected to long duration earthquakes , 2011 .

[36]  Luis Ibarra,et al.  Hysteretic models that incorporate strength and stiffness deterioration , 2005 .

[37]  Dimitrios G. Lignos,et al.  Sidesway collapse of deteriorating structural systems under seismic excitations , 2008 .

[38]  Abolhassan Astaneh-Asl,et al.  Moment–Rotation Parameters for Composite Shear Tab Connections , 2004 .

[39]  Andrew S. Whittaker,et al.  Prediction and validation of sidesway collapse of two scale models of a 4‐story steel moment frame , 2011 .

[40]  Bungale S. Taranath,et al.  Seismic Provisions for Structural Steel Buildings, ANSI/AISC 341-10 , 2016 .