An Approach for Balancing Diagnostic Image Quality with Cancer Risk: Application to Pediatric Diagnostic Imaging of 99mTc-Dimercaptosuccinic Acid

A recent survey of pediatric hospitals showed a large variability in the activity administered for diagnostic nuclear medicine imaging of children. Imaging guidelines, especially for pediatric patients, must balance the risks associated with radiation exposure with the need to obtain the high-quality images necessary to derive the benefits of an accurate clinical diagnosis. Methods: Pharmacokinetic modeling and a pediatric series of nonuniform rational B-spline–based phantoms have been used to simulate 99mTc-dimercaptosuccinic acid SPECT images. Images were generated for several different administered activities and for several lesions with different target-to-background activity concentration ratios; the phantoms were also used to calculate organ S values for 99mTc. Channelized Hotelling observer methodology was used in a receiver-operating-characteristic analysis of the diagnostic quality of images with different modeled administered activities (i.e., count densities) for anthropomorphic reference phantoms representing two 10-y-old girls with equal weights but different body morphometry. S value–based dosimetry was used to calculate the mean organ-absorbed doses to the 2 pediatric patients. Using BEIR VII age- and sex-specific risk factors, we converted absorbed doses to excess risk of cancer incidence and used them to directly assess the risk of the procedure. Results: Combined, these data provided information about the tradeoff between cancer risk and diagnostic image quality for 2 phantoms having the same weight but different body morphometry. The tradeoff was different for the 2 phantoms, illustrating that weight alone may not be sufficient for optimally scaling administered activity in pediatric patients. Conclusion: The study illustrates implementation of a rigorous approach for balancing the benefits of adequate image quality against the radiation risks and also demonstrates that weight-based adjustment to the administered activity is suboptimal. Extension of this methodology to other radiopharmaceuticals would yield the data required to generate objective and well-founded administered activity guidelines for pediatric and other patients.

[1]  L. Lemen,et al.  PET/CT and SPECT/CT dosimetry in children: the challenge to the pediatric imager. , 2007, Seminars in nuclear medicine.

[2]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[3]  R. Vetter ICRP Publication 103, The Recommendations of the International Commission on Radiological Protection , 2008 .

[4]  S. Ted Treves,et al.  Pediatric Radiopharmaceutical Administered Doses: 2010 North American Consensus Guidelines , 2011, The Journal of Nuclear Medicine.

[5]  B. Tsui,et al.  A new method for modeling the spatially-variant, object-dependent scatter response function in SPECT , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[6]  Eric C Frey,et al.  Optimum compensation method and filter cutoff frequency in myocardial SPECT: a human observer study. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  Wesley E. Bolch,et al.  Hybrid Patient-Dependent Phantoms Covering Statistical Distributions of Body Morphometry in the U.S. Adult and Pediatric Population , 2009, Proceedings of the IEEE.

[8]  M. Lythgoe,et al.  Radiation dosimetry of technetium-99m-DMSA in children. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  Suleman Surti,et al.  Improved Dose Regimen in Pediatric PET , 2010, Journal of Nuclear Medicine.

[10]  M. Lythgoe,et al.  Biokinetic behavior of technetium-99m-DMSA in children. , 1996, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  Deanna Hasenauer,et al.  Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models , 2007, Physics in medicine and biology.

[12]  F. Fahey Dosimetry of Pediatric PET/CT* , 2009, Journal of Nuclear Medicine.

[13]  Paul Kinahan,et al.  Weight-Based, Low-Dose Pediatric Whole-Body PET/CT Protocols , 2009, Journal of Nuclear Medicine.

[14]  Icrp 1990 Recommendations of the International Commission on Radiological Protection , 1991 .

[15]  Eric C. Frey,et al.  A fast projector-backprojector pair modeling the asymmetric, spatially varying scatter response function for scatter compensation in SPECT imaging , 1993 .

[16]  Franklin C. Wong,et al.  MIRD: Radionuclide Data and Decay Schemes , 2009, Journal of Nuclear Medicine.

[17]  Eric C Frey,et al.  An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability , 2010, Physics in medicine and biology.

[18]  M. Lassmann,et al.  The new EANM paediatric dosage card , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[19]  S Ted Treves,et al.  Dosimetry and adequacy of CT-based attenuation correction for pediatric PET: phantom study. , 2007, Radiology.

[20]  M. Lassmann,et al.  The new EANM paediatric dosage card: additional notes with respect to F-18 , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[21]  Eric C. Frey,et al.  Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT , 2002, IEEE Transactions on Medical Imaging.

[22]  C. Metz,et al.  Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. , 1998, Statistics in medicine.

[23]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[24]  F. Jacobs,et al.  Optimised tracer-dependent dosage cards to obtain weight-independent effective doses , 2005, European Journal of Nuclear Medicine and Molecular Imaging.

[25]  Division on Earth Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2 , 2006 .

[26]  S. Treves Pediatric Nuclear Medicine , 1984 .

[27]  Thomas F. Budinger,et al.  MIRD primer for absorbed dose calculations , 1988 .

[28]  Wesley E. Bolch,et al.  MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry—Standardization of Nomenclature , 2009, Journal of Nuclear Medicine.

[29]  Daniel Lodwick,et al.  The UF family of reference hybrid phantoms for computational radiation dosimetry , 2010, Physics in medicine and biology.

[30]  Herbert Malamud,et al.  MIRD Primer for Absorbed Dose Calculations , 1989 .

[31]  L. T. Dillman,et al.  MIRD : radionuclide data and decay schemes , 1989 .

[32]  C. Metz,et al.  A New Approach for Testing the Significance of Differences Between ROC Curves Measured from Correlated Data , 1984 .