Dynamic contrast‐enhanced MRI in mice: An investigation of model parameter uncertainties

To establish the experimental factors that dominate the uncertainty of hemodynamic parameters in commonly used pharmacokinetic models.

[1]  D. Buckley,et al.  Perfusion estimated with rapid dynamic contrast-enhanced magnetic resonance imaging correlates inversely with vascular endothelial growth factor expression and pimonidazole staining in head-and-neck cancer: a pilot study. , 2011, International journal of radiation oncology, biology, physics.

[2]  Pascal Verdonck,et al.  Precision analysis of kinetic modelling estimates in dynamic contrast enhanced MRI , 2011, Magnetic Resonance Materials in Physics, Biology and Medicine.

[3]  A. Jackson,et al.  Modeling of contrast agent kinetics in the lung using T1‐weighted dynamic contrast‐enhanced MRI , 2009, Magnetic resonance in medicine.

[4]  E. Rofstad,et al.  Assessment of extravascular extracellular space fraction in human melanoma xenografts by DCE-MRI and kinetic modeling. , 2008, Magnetic resonance imaging.

[5]  David L Buckley,et al.  Uncertainty in the analysis of tracer kinetics using dynamic contrast‐enhanced T1‐weighted MRI , 2002, Magnetic resonance in medicine.

[6]  G. Parker,et al.  DCE-MRI biomarkers in the clinical evaluation of antiangiogenic and vascular disrupting agents , 2007, British Journal of Cancer.

[7]  Thomas E Yankeelov,et al.  Dynamic Contrast Enhanced Magnetic Resonance Imaging in Oncology: Theory, Data Acquisition, Analysis, and Examples. , 2007, Current medical imaging reviews.

[8]  Lucy E Kershaw,et al.  Temporal resolution and SNR requirements for accurate DCE‐MRI data analysis using the AATH model , 2010, Magnetic resonance in medicine.

[9]  J. Folkman Role of angiogenesis in tumor growth and metastasis. , 2002, Seminars in oncology.

[10]  Steven P Sourbron,et al.  Classic models for dynamic contrast‐enhanced MRI , 2013, NMR in biomedicine.

[11]  G. Brix,et al.  Pharmacokinetic analysis of tissue microcirculation using nested models: multimodel inference and parameter identifiability. , 2009, Medical physics.

[12]  W. Rooney,et al.  Cell membrane water exchange effects in prostate DCE-MRI. , 2012, Journal of magnetic resonance (San Diego, Calif. 1997 : Print).

[13]  Michael Jerosch-Herold,et al.  Role of Transcytolemmal Water-Exchange in Magnetic Resonance Measurements of Diffuse Myocardial Fibrosis in Hypertensive Heart Disease , 2013, Circulation. Cardiovascular imaging.

[14]  N A W van Riel,et al.  System identification theory in pharmacokinetic modeling of dynamic contrast‐enhanced MRI: Influence of contrast injection , 2008, Magnetic resonance in medicine.

[15]  Robert Luypaert,et al.  Validity of perfusion parameters obtained using the modified Tofts model: A simulation study , 2011, Magnetic resonance in medicine.

[16]  A. Jackson,et al.  Experimentally‐derived functional form for a population‐averaged high‐temporal‐resolution arterial input function for dynamic contrast‐enhanced MRI , 2006, Magnetic resonance in medicine.

[17]  Hai-Ling Margaret Cheng,et al.  Investigation and optimization of parameter accuracy in dynamic contrast‐enhanced MRI , 2008, Journal of magnetic resonance imaging : JMRI.

[18]  Steven Sourbron,et al.  The Akaike information criterion in DCE-MRI: Does it improve the haemodynamic parameter estimates? , 2012, Physics in medicine and biology.

[19]  P. Gaehtgens,et al.  Flow of blood through narrow capillaries: rheological mechanisms determining capillary hematocrit and apparent viscosity. , 1980, Biorheology.

[20]  A. Haase,et al.  Rapid NMR imaging of dynamic processes using the FLASII technique , 1986, Magnetic resonance in medicine.

[21]  N. Clarke,et al.  Late tissue effects following radiotherapy and neoadjuvant hormone therapy of the prostate measured with quantitative magnetic resonance imaging. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  P. Tofts Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging , 1997, Journal of magnetic resonance imaging : JMRI.

[23]  Ting-Yim Lee,et al.  An Adiabatic Approximation to the Tissue Homogeneity Model for Water Exchange in the Brain: I. Theoretical Derivation , 1998, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[24]  M. Knopp,et al.  Estimating kinetic parameters from dynamic contrast‐enhanced t1‐weighted MRI of a diffusable tracer: Standardized quantities and symbols , 1999, Journal of magnetic resonance imaging : JMRI.

[25]  Jun Yu,et al.  Uncertainty estimation in dynamic contrast‐enhanced MRI , 2013, Magnetic resonance in medicine.

[26]  G. Cokelet,et al.  The Fahraeus effect. , 1971, Microvascular research.

[27]  Thomas E Yankeelov,et al.  A novel AIF tracking method and comparison of DCE-MRI parameters using individual and population-based AIFs in human breast cancer , 2011, Physics in medicine and biology.

[28]  W J Manning,et al.  Studies of Gd‐DTPA relaxivity and proton exchange rates in tissue , 1994, Magnetic resonance in medicine.

[29]  B K Rutt,et al.  Temporal sampling requirements for the tracer kinetics modeling of breast disease. , 1998, Magnetic resonance imaging.

[30]  P S Tofts,et al.  Measurement of capillary permeability from the Gd enhancement curve: a comparison of bolus and constant infusion injection methods. , 1994, Magnetic resonance imaging.

[31]  R. Moots,et al.  Pharmacokinetic modeling of dynamic contrast‐enhanced MRI of the hand and wrist in rheumatoid arthritis and the response to anti‐tumor necrosis factor‐α therapy , 2007, Magnetic resonance in medicine.

[32]  Kenneth Levenberg A METHOD FOR THE SOLUTION OF CERTAIN NON – LINEAR PROBLEMS IN LEAST SQUARES , 1944 .

[33]  E. Meyer Simultaneous correction for tracer arrival delay and dispersion in CBF measurements by the H215O autoradiographic method and dynamic PET. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[34]  D L Buckley,et al.  Enhancing fraction measured using dynamic contrast-enhanced MRI predicts disease-free survival in patients with carcinoma of the cervix , 2009, British Journal of Cancer.

[35]  Tristan Barrett,et al.  MRI of tumor angiogenesis , 2007, Journal of magnetic resonance imaging : JMRI.

[36]  David Hinkley,et al.  Bootstrap Methods: Another Look at the Jackknife , 2008 .

[37]  Eric Jones,et al.  SciPy: Open Source Scientific Tools for Python , 2001 .

[38]  Marco van Vulpen,et al.  Tracer Kinetic Model Selection for Dynamic Contrast-Enhanced Computed Tomography Imaging of Prostate Cancer , 2012, Investigative radiology.

[39]  N. Michoux,et al.  Transvascular and interstitial transport in rat hepatocellular carcinomas: Dynamic contrast‐enhanced MRI assessment with low‐ and high‐molecular weight agents , 2008, Journal of magnetic resonance imaging : JMRI.

[40]  Thomas J Vogl,et al.  Dynamic contrast-enhanced CT of head and neck tumors: comparison of first-pass and permeability perfusion measurements using two different commercially available tracer kinetics models. , 2008, Academic radiology.

[41]  Dow-Mu Koh,et al.  Assessment of the effect of haematocrit‐dependent arterial input functions on the accuracy of pharmacokinetic parameters in dynamic contrast‐enhanced MRI , 2011, NMR in biomedicine.

[42]  P S Tofts,et al.  Quantitative Analysis of Dynamic Gd‐DTPA Enhancement in Breast Tumors Using a Permeability Model , 1995, Magnetic resonance in medicine.

[43]  Maximilian Reiser,et al.  Quantification of cerebral blood flow, cerebral blood volume, and blood–brain‐barrier leakage with DCE‐MRI , 2009, Magnetic resonance in medicine.

[44]  Emile Daraï,et al.  Dynamic contrast-enhanced MR imaging to assess physiologic variations of myometrial perfusion , 2010, European Radiology.

[45]  Clayton Wong,et al.  Rapid measurement of arterial input function in mouse tail from projection phases , 2014, Magnetic resonance in medicine.

[46]  D. Buckley,et al.  Precision in measurements of perfusion and microvascular permeability with T1‐weighted dynamic contrast‐enhanced MRI , 2006, Magnetic resonance in medicine.

[47]  J. Bassingthwaighte,et al.  Modeling regional myocardial flows from residue functions of an intravascular indicator. , 1996, The American journal of physiology.