Quantification of the variability of diaphragm motion and implications for treatment margin construction.

PURPOSE To quantify the variability of diaphragm motion during free-breathing radiotherapy of lung patients and its effect on treatment margins to account for geometric uncertainties. METHODS AND MATERIALS Thirty-three lung cancer patients were analyzed. Each patient had 5-19 cone-beam scans acquired during different treatment fractions. The craniocaudal position of the diaphragm dome on the same side as the tumor was tracked over 2 min in the projection images, because it is both easily visible and a suitable surrogate to study the variability of the tumor motion and its impact on treatment margins. Intra-acquisition, inter-acquisition, and inter-patient variability of the respiratory cycles were quantified separately, as were the probability density functions (PDFs) of the diaphragm position over each cycle, each acquisition, and each patient. Asymmetric margins were simulated using each patient PDF and compared to symmetric margins computed from a margin recipe. RESULTS The peak-to-peak amplitude variability (1 SD) was 3.3 mm, 2.4 mm, and 6.1 mm for the intra-acquisition, inter-acquisition, and inter-patient variability, respectively. The average PDF of each cycle was similar to the sin(4) function but the PDF of each acquisition was closer to a skew-normal distribution because of the motion variability. Despite large interfraction baseline variability, the PDF of each patient was generally asymmetric with a longer end-inhale tail because the end-exhale position was more stable than the end-inhale position. The asymmetry of the PDF required asymmetric margins around the time-averaged position to account for the position uncertainty but the average difference was 1.0 mm (range, 0.0-4.4 mm) for a sharp penumbra and an idealized online setup correction protocol. CONCLUSION The respiratory motion is more irregular during the fractions than between the fractions. The PDF of the respiratory motion is asymmetrically distributed. Both the intra-acquisition variability and the PDF asymmetry have a limited impact on dose distributions and inferred margins. The use of a margin recipe to account for respiratory motion with an estimate of the average motion amplitude was adequate in almost all patients.

[1]  Jan-Jakob Sonke,et al.  Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. , 2006, International journal of radiation oncology, biology, physics.

[2]  Paul J Keall,et al.  An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients , 2008, Physics in medicine and biology.

[3]  S. Shapiro,et al.  An Analysis of Variance Test for Normality (Complete Samples) , 1965 .

[4]  S. Rit,et al.  On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion. , 2009, Medical physics.

[5]  Jan-Jakob Sonke,et al.  Variability of four-dimensional computed tomography patient models. , 2008, International journal of radiation oncology, biology, physics.

[6]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[7]  Philippe Lambin,et al.  Intra-patient variability of tumor volume and tumor motion during conventionally fractionated radiotherapy for locally advanced non-small-cell lung cancer: a prospective clinical study. , 2006, International journal of radiation oncology, biology, physics.

[8]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[9]  Jan-Jakob Sonke,et al.  Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. , 2009, International journal of radiation oncology, biology, physics.

[10]  Mitsuhiro Nakamura,et al.  Measurement of interfraction variations in position and size of target volumes in stereotactic body radiotherapy for lung cancer. , 2009, International journal of radiation oncology, biology, physics.

[11]  John Spencer GRADUATION OF A SICKNESS TABLE BY MAKEHAM'S HYPOTHESIS , 2022 .

[12]  A. Azzalini A class of distributions which includes the normal ones , 1985 .

[13]  Steve B. Jiang,et al.  Gating based on internal/external signals with dynamic correlation updates , 2008, Physics in medicine and biology.

[14]  Lena Specht,et al.  Intra- and interfraction breathing variations during curative radiotherapy for lung cancer. , 2007, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[16]  Shinichi Shimizu,et al.  Intrafractional tumor motion: lung and liver. , 2004, Seminars in radiation oncology.

[17]  Joos V Lebesque,et al.  Biologic and physical fractionation effects of random geometric errors. , 2003, International journal of radiation oncology, biology, physics.

[18]  Steve B. Jiang,et al.  The diaphragm as an anatomic surrogate for lung tumor motion , 2009, Physics in medicine and biology.

[19]  R Mohan,et al.  Is the diaphragm motion probability density function normally distributed? , 2005, Medical physics.

[20]  Jeffrey A. Fessler,et al.  Estimating 3-D Respiratory Motion From Orbiting Views by Tomographic Image Registration , 2007, IEEE Transactions on Medical Imaging.

[21]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[22]  E. Larsen,et al.  A method for incorporating organ motion due to breathing into 3D dose calculations. , 1999, Medical physics.

[23]  P Boesiger,et al.  4D MR imaging of respiratory organ motion and its variability , 2007, Physics in medicine and biology.